α ααααΎαααααΈα ααΎαααααΆαααααΆαααα ααΎααααΆααααααΆ MCB ααΆααααααΌα ααααα ?
α ααααΆααααααΆ MCB αααα αΆαααΈααααα·αα ααααα’αααα·αααΈ αααααααααΆααααααΆα α ααααα·αααα»α αααααααΆαααΆααααααΆα α α ααα½ααααΌα αααααααΆαααααΆαααααΎααααΆαα αα·αα·ααααααααΆααααααααΎα αα·αααΆααααααααααααΆααα ααααααααΆαα (AC) α¬α ααααααααΆαα (DC)α αααααααααααΆαααααΆαααααααααααΎααΉαααΆαααααα»αααΊααΌα ααΆ C16 6000 230/400V~ IEC 60898-1, αααααΆααααααΆααΆ MCB αααααα C-curve ααααα·α 16A αααααΆααα ααααααααΆαα (AC) αααααΆααααααααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit) ααααα·α 6kA ααΆααααααααΆααααααΆααααααα.
ααΌαα’αΆααααααΆαααααΆααααΆαααααΆααααΌα ααΆααααααα
- αααααααααΆααααααΆα α αα·αααααα·αα ααααα B16, C20, D32α.
- ααα»αααααα αα·ααα·αα·ααααααααΆ AC/DCα.
- αααααααΆαααΆααααααΆα αα 6000, 6kA, 10000, α¬ 10kAα.
- αααααααΆαα IEC 60898-1, IEC 60947-2, UL 489, α¬ααΆααααααΆααααΆααααααααααααααα.
- ααΆαααααααα ααΆαααααααααααΌαα 1P, 1P+N, 2P, 3P, 4Pα.
- ααααΆααααΆαααααααααΎα αα·ααα ααααα αΌα/ααααα αα αα·ααααΌαααααα·αααΎααΆαααΆααααααΆααα.
- αααα»αα αα»αααα·α ααααααΌααα αααααΆαααααΆαααα»αααΆα αα·αααΆααααααΆααααααΏααααααΆααα.
ααααα·αααΎα’ααααααα»αααααΎααααΆααααααΆααΎααααΈααααΎαααΎαα§αααααααΆααααααΎαααααΈ ααΌαα’αΆαααααα ααααα»αααααααααΆαααααΎαααΎα MCBα ααααααααΎαααΎαα§αααααααΆααααααααΈααααΆαααΌα (Miniature Circuit Breaker) α±ααααΆαααααΉαααααΌα. α’αααααααααααααααΎααΆαααααααΆααααααΆαααααΆααααΆααΆα.
ααΆααα·αα·αααααΎααααααΆαααααΆααααΎααααΆαααααααααα MCB

| αααααΆαααααΆαα | α§ααΆα ααα | α’αααααα | α αΆαα·ααααααα»αααΆαααααΎαααΎα |
|---|---|---|---|
| αααααααααΆααααααΆα α + α ααααααααα | C16, B20, D32 | α’ααααααααΆααααααααααΌαααΉαα ααααααααααα·αααΆα’αααα | ααΆαααααΎαααΎαααααααααα»αα’αΆα αααααΆαα±ααααΆαααΆαααΆααααααΆα αααααα·αα αΆαααΆα α α¬ααΆαααΆαααΆαααα α»ααα·αααΆαααα’ |
| ααΆαααααααα αα α»αααααα | 16A, 32A, 63A | α ααααααα MCB ααααΌαααΆααα ααΆα‘αΎαααΎααααΈαααα»αααΆαααααααααΆααααααααααααααααααααΆαααααα | ααΆαααααΎαααΎαααα ααααααα’αΆα αααααΆαα±αααααΆααααααα»αααΆαααΆαααΆαααααααααΎα |
| αααααααααααΎααααΎα | B, C, D | αααααααα·αααααααΆαααΆααααααΆα αααααααΆαααα·αααααΆαα | ααααΌαααααααααααΉαααααααααααΆαααΎαα‘αΎαα ααααααααΆααααααααααα»α |
| αααααααΆαααααα | 6000, 6kA, 10000, 10kA | α ααααααααααΆααααααααΈααααΈα’αα·ααααΆααα MCB α’αΆα ααΆααααααΆα αααΆααααααααααααααααααα | ααααΌαααααΎαααΈα ααααααα α»ααααα’αΆα ααααΆα |
| ααα»ααααααΆαααΆαααααα | 230/400V~ | ααααα·αααα»αααααα·ααααα·ααΆαα ααααααααΆαα (AC) | ααααΌαααααααααααΉαααα»ααααααααα αα·αααΆαααααΎααααΆαααααΌα (Pole) |
| αααααααΆα | IEC 60898-1, IEC 60947-2 | αααααααΆααααααααα·ααα/αααααααΆαααααΆαααααΎααααΆαα | ααα·ααααααΆαααααΎααααΆαααααα»ααααα½ααΆα/ααααααααααΆ αααααΉαααΆαααααΎααααΆαααααα»αα§ααααΆα αααα |
| ααΆααααααΆαααααΌα (Pole marking) | 1P, 1P+N, 2P, 3P, 4P | α ααα½α αα·αααΆααααα ααααααΌααααααααΌαααΆααααααΆα α/ααΆαααΆα | ααΆαααααΎαααΎαα ααα½ααααΌααα·αααααΉαααααΌαα’αΆα ααααααΆαααα αΆαααα»αααΆααααααΆααααααααααΎα αα·αααΆαααααΆα αα αααα |
| αα·αα·ααααααααΆ AC/DC | ~, αααααΆ DC, + / β |
ααααααα αααα αα·αααααααααααΌα (polarity) | MCB αααααα AC αα·αα’αΆα αααααααΆααααΎααΆααααααΆαα DC ααααα |
| ααααΆααααΆαααααααααΎα | ααααΆααααΆααααα/ααααα»α α¬ααααΆααααααααΆααααα»α | αααααααα αα ααα»α αααααΆαα (terminals) αα·ααααΌα (poles) | ααΆααααααΆαααα»αα’αΆα ααααΎα±ααααΆααααααα»αααΆαααΆαααΆα α¬ααΆααααα αΆααααααΆ |
| αααααΆαααααΆαααα»αααΆα (Certification mark) | CE, UL, TUV, CCC ααΆααΎα. | ααΆααααα αΆαααΈααααΆα α¬αα·ααααΆαααααα | ααααΌαααααααΌααααααΉααααΌααα αα·ααααααΌαααΆαααααααα±ααααΆαααααΉαααααΌα |
αααααΆααααααααα·ααααα MCB ααΆααααααΌααααΌααΆα ααΌαααΎα ααΎα§ααααααααααααααααΈααααΆαααΌα (MCB) ααΊααΆα’αααΈ?.
ααΎ C16, B20 α¬ D32 ααΆααααααΌα ααααα αα ααΎ MCB?
αααααΆαααααΆαα C16 αα½ααααα αΌαααααααΆαααΈααααααα
α= αααααααααααΎααααΎα16= α αααααααααΆαααΆααααααααΆα’αααα
ααΌα αααα C16 ααΆααααααΆ MCB ααααααααααααα C αααααΆαα αααααααααααααΉα 16Aα.

α§ααΆα αααααααααααα
| αααααΆαααααΆαα | ααααααα (Curve) | ααΆαααααααα αα α»αααααα | ααΆαααααααΆαααΌαα |
|---|---|---|---|
| B10 | ααααααα B | 10A | ααΆαααΆααααααΆα αααααΆαααααααΆαααΆααααΎαααααα ααΆααΏααααααΌαααΆαααααΎαααααΆααααααααΈαααααΆαα ααααα αΆααααααΎαααΆα |
| C16 | ααααααα C | α‘α¦ α | ααααααΈααααΎααααΆααααΌαα αααααΆαα ααααα αΆααααααΎαααααα |
| C32 | ααααααα C | α£α’ α | α ααααααααααΈααΆααΆαααααααΆα ααααα ααααΆαααααααααααααααααααα C |
| D32 | ααααααα D | α£α’ α | ααΆαααααΆααααα ααααα αααααααααααΆααααααα (Inrush) ααΊαααααΆααααααααααΈαααααααααααα»ααααα |
αα»ααααα ααα‘αααΆ C16 ααΊααΆ β16kAβ α¬ βααααααα C ααΌαααΉα 16kAβ α±αααααα αα½αααααααα ααΈαααααα’ααααααααααα ααΊααΆα ααααααααα (Rated current) αα·ααααααΆαααααααΆαααΆααααααΆα α (Breaking capacity) αααααα.
αααααΆααααΆααααααααααα’α·αα’αααΈααααααα ααΌαααΎα ααΆααααααΉαα’αααΈααααΌαααα.
αααααααααΆααααααΆα α (Trip Curves) αααααα B, C αα·α D αα ααΎααααΆααααααΆαα
α’αααααααααααααααΆααααααΆα ααααα αΆαααΈαα½αααααΆαααΆααααααΆα αααααααααααααΆααα αααααΆαα MCB αααααα IEC ααΌαα α
| ααααααα (Curve) | αα½αααααΆαααΆααααααΆα αααααΆααααΆααααααααααααααΆα | ααΆαααααΎααααΆααααΌαα |
|---|---|---|
| ααααααα B | 3-5 x In | ααααα»ααααααΆαα αααααααααααΆααααΆα αα·αααααααααΎαααααααα ααααααααααΆααααΆαααααα·α |
| ααααααα C | 5-10 x In | ααααα»αααΌαα αααΌαααααΌα α αααα»αααααΎαααααααΊ αα·αααααααΈα αααα»α |
| ααααααα D | 10-20 x In | ααααα»ααααααΆαα ααααα αΆααααααΎαααααα (High-inrush loads) ααΌα ααΆαααααααααΌ α¬ααααααΈα αΆααααααΎααααΌαααααα |
αααα»α ααΆααααααΆ α
ααααααααα (Rated current)α.
α§ααΆα αααα MCB αααααα C16 ααΆαα ααααααααα 16Aα αα½αααααΆαααααΆα αααααΆααααααααΆααΆααααααΆααΆααααα αα 5-10 ααααα ααααααααα ααΌα ααααααΆααΆααααα αα 80-160A αααααααααααααααααααααααΆαααααααα.
ααααααα (Curve) αα½αααααααΌαααΆαααααΎαααΎααααααα’ααααΎα ααααα αΆααααααΎα (Inrush current) αα·αααααααααααααααα·αααααααΈααΌα (Fault-loop conditions)α ααΆαααααΎαααΎαα§αααααααΆααααααΎααααααα D-curve ααααΆααααααΎααααΈααααααααΆαααααΆα αααααΎααααααααΆαααΌαα ααα»α αααΆααααΆαα α’αΆα ααΆααααααααααΆαα ααααα·αααΎα ααααααααααΆαααα αααααΆαααα α»α (Fault current) ααΆαααααα·αααΆαααα ααααα·αα’αΆα ααααΎα±ααααΆααααΆα αααΆαααΏαα.
α ααααααααα (Rated Current) αααααΉα αααααααΆαααααΆα αα αααα (Breaking Capacity)
αααααΆαααααΆααααΈαααααααααα ααα‘αααααΆα
- ααΆαααααααα αα α»αααααα: ααααα·αα ααααααααααΆ ααΌα ααΆ 16A α¬ 32Aα.
- αααααααΆαααααα: ααααα·ααααααααΆαααααΆα αα αααααα αααααΆαααααααΈααααΈ (Short-circuit interruption rating) ααΌα ααΆ 6000A α¬ 10kAα.

α§ααΆα αααα
C16 6000
αααααΆααααααΆα
C16= ααααααααααααα C, α ααααααααα 16A6000= αααααααΆαααααααααΉαααΆαααααα ααααααααΈ 6000A ααααααα·ααα α ααΆ 6kA
MCB αα·αα’αΆα αααα»αα αααα 6000A ααΆαααΆαααααααααΆαααααααα ααΆααααΌαααΆααααααααΎααααΈααΆααααααΆα αααααα·αα ααααααααααααΈααα αααααααααααααααααααααααΆααααααΆααα.
αααααΆααααααααΆααααα’α·α ααΌαααΎα αααααααΆαααΆααααααΆα αα αααααααα MCB ααα α 6kA αααααΉα 10kA.
ααΎ 6000, 6kA, 10000 α¬ 10kA ααΆααααααΌα ααααα ?
MCB α’αΆα αααα αΆααααααααΆαααΆααααααΆα αααΌα ααΆα
60006000A6kA1000010kA
ααααααα αα ααΎαααααααΆαααΆααα ααααααααααΆαααααααΆαααΆαααααα ααααααααΈ (Short-circuit) ααΆααααααααΆα αα·αααα»ααααααΆααααααα.
| αααααΆαααααΆαα | α’αααααα |
|---|---|
| 3000 α¬ 3kA | αααααααΆαααααα ααααααααΈ 3,000A |
| 4500 α¬ 4.5kA | αααααααΆαααααα ααααααααΈ 4,500A |
| 6000 α¬ 6kA | αααααααΆαααααα ααααααααΈ 6,000A |
| 10000 α¬ 10kA | αααααααΆαααααααααΉαα ααααααααααΆαα (Short-circuit capacity) α‘α ,α α α α’αΆααα |
ααααα·αα αααααααααααΉαααααΌαααΊα’αΆααααααα ααΎα ααααααααααΆαααααααααΉααα»ααα α ααα»α ααα‘αΎαα αΰΈΉΰΉααααΎαααααα αα·ααααααααααΌα’αΆα ααααΌαααΆααααααααΆαααΆααααααΆα ααααααααΆαααααααΈααααα ααααΆαααΈαααααα.
αααααΆααααα·ααααααΆαααααΆ ααΌαααΎα How to Calculate Short Circuit Current for MCB.
Icn αααααΉα Icu αααααΉα Ics αα ααΎααααΆααααααΆ MCB
MCB αααααααα αΆα Icn, αααααααααααααααααααα αΆα α’ααΈαα» αα·α α’αΆα. α ααΆαααααΆαααααααααΈααα·αααααααααΆαααααααααααΆα.
| αααααΆαααααΆαα | ααα·αααααααααΆαααΌαα | α’αααααα |
|---|---|---|
| Icn | IEC 60898-1 | αααααααΆαααααααααΉαα ααααααααααΆαααααααΆαααααααααααΆαα MCB ααααΎααααΆαααααα»αααα ααααΆα αα·ααααααα·ααΈααααααααααΆ |
| α’ααΈαα» | IEC 60947-2 | αααααααΆαααΆααααααΆα αα ααααααααααΆααα’αα·ααααΆ (Ultimate short-circuit breaking capacity) |
| α’αΆα | IEC 60947-2 | αααααααΆαααΆααααααΆα αα ααααααααααΆαααααα»ααααααααα·ααααα·ααΆα (Service short-circuit breaking capacity) |
αα»αα αΆαααα»ααααααΆαααααΆααααΆαααααααΆααΌα ααααΆα MCB αααααααΎαααααΆαααααα ααααΆα αα·αααααααΈα α»ααααααααααααααααΆ α’αΆα αααα αΆααα·ααααααααΆααααααααΆα IEC 60898-1 ααΌα ααΆ Icn ααΆααΎαα α αααα MCB α§ααααΆα ααααααααααααΎαααΎαααααα DIN-rail ααα’αΆα ααΆαααααα·αααΆααααααααΆααααααααΆα IEC 60947-2 ααΌα ααΆ Icu αα·α Ics αααααα.
αααααΆαααααΆαααααααααΊααΆααααα ααΌαα’αΆαααααααααααααΆαααΆααααααΆα αα αααα ααααΆααααΆαα½ααααααααΆα ααα»α αα·αααα·ααααααΆαααααΎααααΆααα αααααΆαααααΆαα β10kAβ αααααααΆααααααααΆα αα·αααα»αα’αα»αααααα ααΊαα·ααααααααααααα.
αααααΆααααΆααααααααααααααααΆαα±ααααΆαααααααΈααααα ααΌαααΎα IEC 60898-1 αααααΉα IEC 60947-2 αααααΆαα MCB. αααααΆααααΆααααα αα αααααααααΆαααΆααααααα§αααααααΆααααααΆα αα αααα (Breaker) ααΌαααΎα Icu αααααΉα Ics αααααΉα Icw αααααΉα Icm.
ααααα’αΆαααα»ααααααΆαααΆαααααα αα·ααα·αα·ααααααααΆ AC/DC
αααααΆαααααΆααααα»ααααα αΆαααΈααααααααα MCB α’αΆα ααααΎααααΆααααΆαα.
α§ααΆα αααααΌαα α
| αααααΆαααααΆαα | α’αααααα |
|---|---|
230V~ |
ααααα·αααα»αα ααααααααΆαα (AC) ααααΆααααΆααααα½α |
230/400V~ |
ααααα·αααα»αα ααααααααΆαα (AC) αααααΆααααααΎααααΆαααααΆαααααα αααΆααα·αααααααΊα α¬αααΆαααααα αααΆααα·αααααα αααΆα α’αΆαααααααΎααΆααααα αα ααα½ααααΌα |
400V~ |
ααΆαααααΎααααΆααα ααααααααΆαα (AC) ααΈααααΆααααΆααααΆαααααα αααΆααα·αααααα αααΆα α’αΆαααααααΎααα·ααααα·ααααααααααΌα |
ααΈ.αααΈ, ααΈααΈαααΈ, +, - |
ααααα·αααα»αα ααααααααΆαα (DC) α¬ααααααΆαα’αααΈαααΌα (Polarity) |
αααααΆ tilde (~) ~ ααΆααααααΆα
ααααααααΆαα (AC)α ααΆαα·αααΆααααααΆα’αΆα
ααααΎααΆαα½αα
ααααααααΆαα (DC) ααΆααααααα.
MCB αααααα AC αα·ααα½αααααΌαααΆαααααΎαα αααα»αααααααΈ DC αα αα»αααααΆααααααΆααααααΆααα·ααα αα·ααααααΉααα·αααααααα αα ααααααααααΆαααααΆαα αααΆααα’αααΈααααα·αααα»α DC αα·ααα·ααΈααΆααααααααααΆααααααα ααΆαααΆααααααΆα αααααΌααααΎα (Arc) ααα αααα DC ααΆαααΆααα»αααααΆααΈα αααα AC α αΎαα§αααααααΆααα αααα DC αα½αα ααα½αααΆαααΆααααΎααα ααΉααααΌα (Polarity)α.
αααααΆαααααα αΆααΆααααΆααααα αααα DC ααΌαααΎα αααΌαααα§αααααααΆααα αααα DC (DC Circuit Breaker Polarity): ααααα»αααααααααααΈααΈ MCB αααααα DC αααααΆααααΌα αα·αααααΆααααΌα.
ααααα’αΆααααααΆαααααΆααα ααα½ααααΌα (Pole): 1P, 1P+N, 2P, 3P, 4P

αααααΆαααααΆααα ααα½ααααΌαααααΆααα’αααααΈα ααα½αααααα ααααααα MCB ααααΎααΆαααΆααααααΆα α α¬ααΆαααΆαα.
| αααααΆαααααΆαα | α’αααααα | ααΆαααααΎααααΆααααααααΆα |
|---|---|---|
| 1 ααΈ | ααααααααΆαααΆααα½α | ααααααΆαα ααααα’αααα·αααΈαααααΆααααααααααα αααΆααααα½α (Single-phase) αααα»αααααααααααΆα αααΎα |
| 1P+N | ααααααααΆαααΆααα½αααΌααα½αααΉαααΆαααΆααααααΆα αααααααΊα (Neutral) α’αΆαααααααΎααΆααα ααΆ | ααααααΈα αααΆααααα½ααααααααΌαααΆαααΆαααααΆα αααααααΊα |
| 2 ααΈ | ααααααααΈα | ααΆαααααΆα αααααα αααΆααααα½ααααααΆαααααααααΈα αα·αααααααΈα ααααααααΆαα (DC) αα½αα ααα½αααααα·αααΎααΆαααΆααααααααααα·αααααΉαααααΌα |
| 3 ααΈ | ααααααααΈ | ααααααΈααΈα αααΆα (Three-phase) αααααααΆαααΆαααΆααααααΆα αααααααΊα |
| α€P | αα½ααααΌα (Four poles) | ααααααααααΈα αααΆαααΌαααΉαααΆαααΆααααααΆα αααααααΊα (Three-phase plus neutral switching) |
αα»ααααααααΆ 1P+N ααΌα ααααΆαα ααΉα 2Pα αα αααα»αα§ααααα 1P+N ααΆαα αααΎα ααΆααααααΌαα αααΆαααα»ααααααααααΆααα»αααΆαααΆαααΆαα ααααααΎα (Overcurrent protection) α αααααααΌαααΊαααααΌαααΆαααΆααααααΆα αααα»αααααα·αααΆααα»αααΆαααΆαααΆαα‘αΎαα ααΌααα·αα·αααααααΆααααΆαααααααααΎαααΆαα·α αα α.
IEC 60898-1 αααααΉα IEC 60947-2 αα ααΎααααΆααααααΆ MCB

ααΆααααααΆααααΆααααααααΆααα½αα±ααα’ααααααααΈααα·ααααααΆαααααΎααααΆαααααααΆααααααα.
| αααααααΆα | ααα·ααααααααΆ | α’αααΈαααααααΌααα·αα·ααα |
|---|---|---|
| IEC 60898-1 | ααΆαααααΎααααΆαα MCB αααααΆαααααα αα·αααΈααΆααααααααααααΆ αααααΆααΌαα ααααα·ααααα·ααΆααααααα»αααααΌαα | Icn, ααααααα B/C/D, ααΆααααααααααααΆααααααααΈα α»αααααα (Final circuit) |
| IEC 60947-2 | α§αααααααΆααα ααααα’αααα·αααΈααααααα»αααΆααααααΆααα§αααααααααΌα αα·αα§ααααααααααΆαααα»αα§ααααΆα αααα αααααΆααΌαα ααααΌαααΆαααααΎαααΎααααα’αααααααΆα | Icu, Ics, ααα·ααααααΆαααααΎααααΆαα, αα·ααααααα§ααααΆα αααα |
| UL 489 | αααααααΆαα§αααααααΆααα ααααα’αααα·αααΈαααααΆααααααααΈααΆααΆαα α’αΆαααα·αααΆαααΎα | ααΆαα α»ααααααΈ UL, ααααααααααααααα»α, ααααα·αααααΆαααΆααα αααα, ααΆαααααΎααααΆααααΆαα½αααααΆαααααααΆ |
MCB αααααα DIN-rail α§ααααΆα αααααα½αα ααα½αα’αΆα ααΆααα·ααααααααΆαα IEC 60898-1 αα·α IEC 60947-2 ααα»ααααα’αααααααΌααααααααααααΆαααααΌααα αα·ααααααΉααα·ααααααα±ααααΆαα αααΆααααΆααα αα»αααααα·ααααΆαααΆααΆααΆααα·ααααΆαααααααααααααΆαααΈααααααααΆααααααΎαααΌαααΆαααΆααααα α.
α§ααΆα αααααΆαααααααα ααΆαααααααΆααααααΆαααααΆαααα ααΎ MCB ααΌαα
α§ααΆα ααααααααααΆαααααΆααα
C16 6000 230/400V~ IEC 60898-1 1P
ααααα’αΆαααΆα
| ααααα | α’αααααα |
|---|---|
α |
αααααααααΆααααααΆα ααααααα C |
16 |
α ααααααααα α‘α¦α’αααα (16A) |
6000 |
αααααααΆαααααααααΉαααΆαααααα ααααααααΈ α¦α α α α’αααα α¬ α¦ααΈα‘αΌα’αααα ααααααααααααααααααΆαααααα |
230/400V~ |
ααααα·αααα»αα ααααααααΆαα (AC) |
IEC 60898-1 |
αααααααΆα/ααα·ααααααΆαααααΎααααΆαα |
1 ααΈ |
α§αααααααΆααα ααααα’αΌααΌ (MCB) αααααααα½ααααΌα |
α§ααΆα αααααααα·αα’αΆα αααααΆααααΈααΆαααααααααααααα½αα―αααΆαααα α’ααααα ααααααΌααα·αα·αααααΎαα
- αααα»ααα αα α»αααααα
- ααα αααααααααΎα αα·ααα·ααΈααΆαααααααα‘αΎα
- α αααα short-circuit αααααααΉααα»α
- αααααααααααααα AC α¬ DC
- αααααααααΆααααααΆα α (Trip curve) αα·αα ααααααααα (Inrush current)
- ααΆααααα αα ααα½ααααΌα (Pole arrangement)
- αααααααααααα·αααα»ααααα»α α¬αααααααααα αα ααααααααααααα
- αααααΉααα·αααααααα αα αααααααααα’αααααα·α
αααααΆααααααΎαααΆαααααΎαααΎααααααα ααΌαααΎα ααααααααΎαααΎαα§ααααααααααααααααΈααααΆαααΌα αααααααΉαααααΌα.
ααα α»αααΌαα αα αααα’αΆαααααΆααααααΆ MCB
ααα α»αααΈα‘α ααΆαααΆααα ααα‘ααααΆαα ααααααααα (Rated current) αα·ααααααααΆαααΆααααααΆα α (Breaking capacity)
C16 αα·α 6000 αα·ααααααΆααααααααααΆααααααααααα·αααΌα
ααααΆααα C16 αααα αΆαααΈααααααα αα·αα
αααααααααα 6000 αααα αΆαααΈαααααααΆαααααααααΉαααΆαααααα
ααααααααΈ (Short-circuit capacity)α.
ααα α»αααΈ α’α ααΆαααααΎααααΆαααααα½α α‘α’α₯% αααααααΈαααααα
αααααΌααα½αα ααα½α αα·αααΆαααααΎααααΆααααααα»αααααααΆαααΆαα±ααααΆαααΉαααα αααΆααααΆαα ααα»ααααααααα·ααααααΆαααα½αααααααααΆααααΆαααα‘αΎα MCB ααααααααααααααααα ααΆαααααΎαααΎα MCB ααααααΌααααα·α αΆαααΆααΎαααααααΆααααα»αα ααααααααααααααααΎα ααααααααααα»α αα·ααΈααΆαααααααα‘αΎα ααΈαα»ααα ααΆααα»ααα·α αα·ααααααααααααα·αααα»ααααα»ααααααα.
ααα α»αααΈ α£α ααΆααααααααΆ MCB ααααα·α 6kA ααΆααα’ααααΊααΌα ααααΆ
αααααααΆαααΆααα αααα (Breaking capacity) ααααΌαααα’αΆααααααα’ααααΎααα»α αααααααΆα ααΆααααα ααααααα αα·ααααα»αααα·αααα α§αααααααΆααα ααααααΈααααααΆααααααΆ 6kA αα·αααααΆααααΆα’αΆα ααααΎαααα½αααααΆααΆααααααα.
ααα α»αααΈ α€α ααΆααα·αα’αΎααΎααΉααααααααααΆααα αααα (Trip curve)
C16 αα·α B16 ααΆαα αααααααααααΌα ααααΆ ααα»ααααααΆαααααα·ααααααΆααα ααααααααΆαααα»αααααΆα ααΆαααααΎαααΎαααααααααα»αα’αΆα αααααΆαα±ααααΆαααΆαααΆααα αααααααααααΆαααΌαα ααα» α¬ααΆααααααααΆααααα αΆααΌα ααΆαααΊααααΆαα.
ααα α»αααΈ α₯α ααΆαααααΎααααΆαα MCB αααααα AC αααα»αααααααΈ DC
αααα ~ αα·αα·ααααααααΆααΆααααααΆ ACα ααααααΈ DC ααΆαααΆαα±ααααΆαααα»α DC αα·αααααα·αααΆααα
αααααααα
αααΆααααΆαα ααΌααα½αααΆααααΆααααααΆααααααααααΎα αα·ααααΌα (polarity) α±ααααΆαααααΉαααααΌαααααα·αααΎααΆαααΆααααααα.
ααα α»αααΈ α¦α ααΆααααα ααα‘αααΆ 1P+N ααΌα ααααΆαα ααΉα 2P
ααΆααα ααΆαααΌα (Pole) ααΆαα₯αααα·ααααΎααΆαααΆαααΆα ααΆαααΆααααααΆα αααααα’ααααΆααααΉα αα·αααΆααααααΆααααααα ααΌααα·αα·αααααΎαααααΆααααΆαααΆααααα»αααΆαα·α αα α.
ααα α»αααΈ α§α ααΆααααα½ααααααα’ααααΎααααααΆααααααΆααΆααα»αααα»ααααα
αααααΆααααΆααααα½α ααΌααα·αα·αααααΎαααααααααααα‘αΎα ααΆαααααααΆαααααΆαααααΆαα (Busbar) ααα αααααΆααααααΆαα ααΆααααα ααααΌα αα·ααααΆαααααα αα·αα―αααΆαααααα’αααααα·α αα·ααααααααΉααααααααα αααα αα·αααααααα (Curve) ααα»αααααααα.
αααααΈαααα½ααα·αα·αααααΎααααΆααααααΆ MCB αα»ααααααααΎαααΎα
αα»ααααα’αα»ααα α¬αααα½α MCB ααΌααααααααΆα
| αα·αα·ααα | αααα½α |
|---|---|
| ααΆαααΆαααααααα αα α»αααααα | ααΎ In ααααΌαααααΆααΉααααααΌαααΆααααα»α αα·αααΆαααΆαααΆαααααααααΎααααα¬αα? |
| αααααααααααΎααααΎα | ααΎααααααα B/C/D ααααΌαααααΆααΉαααααααααααα ααααααααα (Inrush) αα·αααααα·ααα»αααα α»α (Fault-loop) αααα¬αα? |
| αααααααΆαααααα | ααΎ Icn/Icu/Ics ααααααααααααααΆαααααααΆααα ααααααααααΆαααααααΆαααα α»α (Fault current) αααα’αΆα ααΎαααΆααααα¬αα? |
| ααα»α | ααΎααααα·αααα»α (Rating) ααααΌαααααΆααΉαααααααααααα»α AC α¬ DC αααα¬αα? |
| αααααααΆα | ααΎααΆααααααΆααααΆααααααααΆα IEC 60898-1, IEC 60947-2, UL 489 α¬αααααααΆααααααααα ααααΌαααααΆααΉααααααΌαααΆααααααααααα¬αα? |
| αααααα | ααΎα ααα½ααααΌα 1P, 1P+N, 2P, 3P α¬ 4P ααααΉαααααΌααααααΆααααααααΈααααααα¬αα? |
| ααΆαααααα | ααΎααααΆααααΆαααααΌαααααΆααΉααα·ααα ααααααααααΎα (Line/Load) αα·αααΆααααα αααααααΊα (Neutral) αααα¬αα? |
| αααααααΆαααααΎααααΆαααααααΆαααααααααα DC | ααααα·αααΎααΆαααααααα DC ααΎα§ααααααααααααΌαααΆααααααααΆααααΎαααααΆαα DC αααααααΆαα αα·αααΆαααΆααααααΆααααααααααΉαααααΌααααα¬αα? |
| ααααΏααααααΆαα | ααΎααααΏααααααΆααααααααααΌα ααΆ Auxiliary contacts, Shunt trips α¬ Busbars ααΆαααΆαααααααΆαααα¬αα? |
| ααααααΌααα | ααΎααΆααααα½ααααααααΌαααααΆααΉααααα»αααα·ααα αα·ααααααΉααα·αααααααα αα ααααα (datasheet) αααα¬αα? |
αααααΆααααΆααα·α αα·αααΆαααααΎαααΎαα’ααααααααααααα ααΌαααΎα MCB α αα»αααα·α αα·α VIOX MCB αααααααα·αααα.
αααα½ααααα½αααΉαααΆαα
ααΎ C16 ααΆααααααΌα ααααα αα ααΎ MCB?
C16 ααΆααααααΆ MCB ααΆααααααααααΆααααααΆα ααααααα C (C trip curve) αα·αααΆαα αααααααααααααΉα 16Aα α’ααααααΊααΆαααααααααααααααΆααααααΆα α α αααααα½αααααΊααΆααααα·αα αααααααααα.
ααΎ 6000 ααΆααααααΌα ααααα αα ααΎ MCB?
6000 ααΆααααααΆααΆααααααΆ 6000A α¬ 6kA αααααΆαααααααΆαααΆααααααΆα αα ααααααααααΆαα (short-circuit breaking capacity) ααααααααααααΆα αα·αααααααααααααααα»ααααααΆααααααα.
ααΎ 10kA αα ααΎ MCB ααΆααααααΌα ααααα ?
10kA ααΆααααααΆα§αααααααΆααα ααααααααΌαααΆααααααα±ααααΆααααααΆα αα ααααααααααΆαα (short-circuit current) αα αΌαααα 10,000A αααααααααααααααααααααααΆααααααΆααα ααΆαα·αααΆααααααΆα§αααααααΆααα ααααα’αΆα αααα»αα αααα 10,000A ααΆαααΆαααααααααΆαααααααα.
ααΎαααααΆ tilde (~) ααΆααααααΌα ααααα αα ααΎ MCB?
αααααΆ tilde (~) ~ ααΆααααααΆ ACα ααΆαααα αΆαααΈααααα·αααα»ααααααΆααα
ααααααααΆααα ααΆαααααΎααααΆααααΆαα½αα
ααααααααΆαα (DC) ααααΌαααααΆαααΆααααααΆαααααα‘αα α¬αααααααααΆααααΈαααααΉααα·αααααααα
αα
αααααα.
ααΎα’αααΈααΆααΆααα»αααααΆαααΆα MCB ααααααααααααα B αα·ααααααα C?
MCB αααααα B ααΆααΌαα ααΉαααΆααα ααααααααααααααααααΆαααα·ααα αααα ααααααΎαααΈ 3 αα 5 ααααα αααααααααα MCB αααααα C ααΆααΌαα ααΉαααΆααα αααααα αααα ααααααΎαααΈ 5 αα 10 ααααα αααααααααα αααααα C ααΆαααΆααααααααΆαααΆαααα’ααΆαα ααααα ααααα αΆααααααΎα (Inrush current) ααααα·ααααααα.
ααΎα’αααΈααΆααΆααα»αααααΆαααΆα C16 αα·α C32?
ααΆααααΈααααααΊααΆ MCB ααααααααααααα C ααα»αααα C16 ααΆαααααα·αα αααα 16A α αΎα C32 ααΆαααααα·αα αααα 32Aα ααααα·αα αααααααααααΆααα·ααααααΆααααααΆααΆααΆααα»ααααα·ααΆαααΆααααααααααααααααα·ααααα ααΆααααΌααααααααααα ααΉαααα αααααααααΎααα·αααααα»αααααΎααααΆααα.
ααΎ Icn αα ααΎ MCB ααΆααααααΌα ααααα ?
Icn ααΊααΆαααααααΆαααΆααα ααααααααΆαααααα»αααααΈααααα αααα (Short-circuit capacity) αααααΆααΌαα ααΆααααααΉααααααααΆα IEC 60898-1 αααααΆαα MCBα ααΆαααα αΆαααΈααααα·αα αααααααα§αααααααΆααααααΎαα’αΆα ααΆααααααΆα αααΆαααααα»ααααα·ααΆααααααααααααααααααααααααααααΆααααα.
ααΎ Icu ααΌα ααααΆαα ααΉα Icn αααα¬αα?
αα Icu ααΊααΆααααα·ααααααααΆαααΆααααααΆα αα ααααα’αα·ααααΆααΆααααααααΆα IEC 60947-2α α αααα Icn ααααΌαααΆαααααΎααααΆαααααα»αααα·αααααααααααΆα IEC 60898-1α ααΌαα’αΆααααααααΈαα½αααααααα’ααααΎαααααααΆα αα·αααααααααααααααα»αααααααΆα.
ααΎαααα»αα’αΆα αααα½α MCB αα½αααααααΆααααααααΆααα ααααα·αααΎααΆααααααΆααααΎα§αααααααΌα ααααΆ?
αα·αα’αΆα ααααΎααΆααααααααααααααααα·ααα αααααΈααΆααααα·αα ααααα’αααα·αααΈααΌα ααααΆααααα ααα»ααααααΆαααα‘αΎα, ααΆαααααααΆαααααΆαααααΆαα (Busbar), ααα αααααΆααααααΆαα, αα·ααααΆαααααα, ααααΏααααααΆαα αα·αααΆαα’αα»αααααΎααΌααααΎαα’αΆα ααΆαααΆααα»αααααΆα.
ααΎαααα»αα’αΆα ααααΎ MCB αααααα AC αααααΆααα αααα DC ααΆααα?
ααΆααα»αααααΆαα MCB αααααααΌαααΆααααααΆαααααΆαα αααΆααααΆα’αΆα ααααΎααΆαα½α DC αα·αααΆαααα‘αΎαααΆαααααΆααααΆαααααααααΎα DC ααααααΆα ααααα·αα αααα AC αααα½ααα»ααα·ααααααααααΆαααααααΆααααααααΈ DC αααααα.
αααααα
αααααααααααααα MCB ααΊααΆαααααααα αα αααααααααααα ααΎααααΈα’αΆαααΆα±ααααΆαααααΉαααααΌα ααααΌαααααΌαααααααΆαααααααα (Curve) αα·αααααα·αα αααα (Current rating) αααααΆαααααα·αα·αααααΎααααααααΆαααΆααααααΆα αα αααα, ααααααα»α, αααααααΆα, ααΆααααααα ααα½ααααΌα, αα·αα·ααααααααΆ AC/DC, ααααΆααααΆαααααααααΎα αα·ααα·αααααααααΌαααα.
ααΆααα»αααααΆααααΆααααΊααΆααααα
C16ααααΆααα’αααα’αααΈααααααα (Curve) αα·αααααα·αα αααααααααΆαααααα (Rated current)α.6000α¬6kAαααα αΆαααΈαααααααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit capacity)α.230/400V~αααα αΆαααΈααΆαααααααααααα»αα ααααααααΆαα (AC voltage)α.IEC 60898-1α¬IEC 60947-2αααα αΆαααΈααα·αααααααααααΆααααααΆαααααααα.1 ααΈ,1P+N,2 ααΈ,3 ααΈ, α¬α€Pαααα αΆαααΈααΆααααα αα ααα½ααααΌα (Pole arrangement)α.
ααΎααααΈααααΎαααΎαααααα»ααααα·ααΆα αα»αα’αΆααααααααΆαααααΆααααΆαα½αααΆα ααααα‘ααα ααΌαααααΎααααΆααααααΆααααααΆααα·ααα (Nameplate) ααααΆααααΆαα½ααααααΉααα·αααααααα αα ααααα (Datasheet) ααΆααααααααα αααααααααΎα α ααααααααααα α»ααααααΆαααααΆαα ααααααααααα»α αα·ααααααααΆααααααααααααΆαααααααα.
Sources Used
- ααααα VIOX αα αα α»ααααααα ααααα’αΆαααααΆααααααΆααΎα§αααααααΆααα ααααα’αΌααΌ (MCB)
- αα·αααααΆαααΌαα ααα§αααααααΆααα αααα (Circuit breaker) αα·ααα½ααααααααααΌαα αααα MCB
- VIOXα ααΆααααααααααααΆααααααααΆα IEC 60898-1 αα·α IEC 60947-2
- VIOX: αααααααΆαααΆααααααΆα αα αααααααα MCB 6kA αααααΉα 10kA