α α§αααααααΆααααααΆα α α¬ α§αααααααααΆα αα αααα αααααααΌαααΆαααααΆα αα ααααα’αααα·αααΈααααα»ααααα·ααΆααα αααααΎα; α ααααα― a α§αααααααααΆα αα αααα αααααααΆαααα»αααΆαααααΆα αα αααα αα·αααΆαααΆαααα ααααααΆαααααα·ααααα»α; α ααααα― a αα»αααΆαααααααααααα»α ααααΌαααΆααα ααΆα‘αΎαααΎααααΈααΆαααα αααααααα»αααααααΆ; αα·α a αα»αααΆααααααΆα αα αααα (Disconnect switch) ααΊααΆααΆαααααΌααααΌααΆα ααααααα·ααααααΎααΆαα·ααααα αααα»αααα·ααα’αΆαααα·αααΆαααΎα αααααΆααα§ααααααααααααΎααΎααααΈααααΆα αααΆαααα’αααα·αααΈα.
α ααα»α ααααα½αα±ααα ααααΌαα ααααααααααΊααΆ ααΆαααααΆαααααα αααΎαααααααΌαααΆαααααΎααααΆααααααα·αααΆαααΆαα αααΆααααΆαααα αααα»αααΆααΆα‘α»α ααααΌαααααα αα·αααΆααα·ααΆααααΆαα ααΆαααααΆαα αααααΆαααΆαααΆααααα αααα»αααΆαααααΎαααΎαααααααα·ααααααα ααααααααα½ααα»ααα·ααααααααααΆαααααααα α’αααααααΌααααα·αα·αααααΎαααα»αααααα (Rated voltage) α ααααααααα·ααααα·ααΆαααααα (Rated operational current) ααααααααααΆαααααΎααααΆαα (Utilization category) αα»αααΆαααααΆα αα αααα (Isolation function) ααΆααααααααααα½ααααααΆαααααααΈααααΈ (Short-circuit coordination) αα·αααΆααΎααΆααααΌαααΆαα’αα»ααααΆαα±ααααααΎαααααΆααα ααααααααΆαα (AC) α¬α ααααααααΆαα (DC)α.
ααααααααααΆααααΎαα·ααΆαααΆαα α’αααααααααααααααααΆαααα ααΎ α§αααααααααΌα αα·αα§ααααααααααΆααααααα»αααΆα, ααΆαα·αααααΊααΆααααα αα αααααααΆααααααααΆα IEC 60947-3 αααααααΎαααααΆαααα»αααΆαα (switches), α§αααααααααΆα αα αααα (disconnectors), αα»αααΆααααααΆα αα αααα (switch-disconnectors) αα·αα§ααααααα½ααααα αΌαα ααα»ααααΈα (fuse-combination units)α α§αααααααααααα»αααααα αα·αααααααα»ααααααα’αΆα ααααΎααΆααααααααΆααααααααΆ ααα»αααααααααααΆααααααααΌαα’αα»αααα ααΆαααααα·α αα ααααα ααΆαααΆαααα αα·αααΈαα·αα·ααΈαα»ααααα·ααΆαααΊαα»αααααΆ ααΌα ααΆαααααΈ IEC 62271 αααααΆααα§αααααααααΌαααααααα»ααααααααΆααΎαα.
ααΆααΆααααααααααα αα
| ααΆααα | αααα·ααααα·αα·ααααααααΆααααααΈααΆαααα | α’ααααααααααΌα | ααΎα’αΆα ααΆααααααΆα αα αααααααα»αααΆααααα¬αα? | αααααααααααΆαα | ααΆαααααΎααααΆααααααααΆα |
|---|---|---|---|---|---|
| α§αααααααααΆα αα αααα | ααΆαααΎαααααΆαααααααααααΆααααααΆαααααΆαααααααΆαααΆα ααααα‘αα | ααΆαααααΌαα αααααΆααα§ααααααααααααΎααΎααααΈααααΆα αααααααΈ | α’αΆαααααααΎααΆααα ααΆ αα·αααααα·αααα»α/α αααα (rating) | ααΆαααααΆα αα ααααα’αααα·αααΈααααα»ααααα·ααΆααααααΆααααΆαααααΆα | ααΆααααΌα’αααα·αααΈ ααααΏαα ααα αα·αααααααααααΆααααααααΊααααα’αΆαα·ααα (PV) |
| αα»αααΆααααααΆα αα αααα (Disconnector) | αα·αα·ααααααααΆαααα αΆαααΈαα»αααΆαααααΆα αα αααα α¬ααααΆααααααααΎαα αα ααΆααααααααΆα IEC | α§ααααααααααααααα»αααΆαααααΆα αα αααααα ααααααα·ααααα»αααΈααΆααααΎα (Open position) | ααΆααΌαα ααΊαα·αα’αΆα αα ααΎααααααααΆαααΆααααααααααα·αααα»α α¬α αααααααααααΈααα | ααΆαααααΆα αα αααααα αααααααΆαααααα»α (Off-load isolation) | ααα·ααααΆαααααΌαα αααα (Switchgear) ααΆααααΌα’αααα·αααΈ αα·αααΆαααααΆα αα αααααααααΆααααΆαααααΆα |
| αα»αααΆααααααΆα αα αααα (Switch-disconnector) | αα·αα·ααααααααΆα§ααααααα·αααΎαααΌααα½αααΉααααααΆαααααΆαααα»αααΆαααααΆα αα αααα | α§αααααααααα½ααααα αΌααα»αααΆααα·αααΎα αα·ααα»αααΆαααααΆα αα αααα | ααΆα αααα»αααααα·αααααα»ααααααΆαααααα | ααΆααα·αααΎαααααα»αααΌααα½αααΉαααΆαααααΆα αα ααααααααα»ααααα·ααΆα | ααΆααααΌα’αααα·αααΈααααααα»αααΆα αα»αααΆαααα αα·αα§αααααα§ααααΆα αααα |
| αα»αααΆααααΆααααααα»α (Load break switch) | αα·αα·ααααααααΆα§ααααααα·αααΎαααααααααααααααααΎααΆααα·αααΎαααααα»α | α§ααααααα·αααΎααααααααΌαααΆααα ααΆα‘αΎααααααΆααααααΆαα αα·αααααΆα αα ααααααααα»αααααααΆ | ααΆα | ααΆααα·αααΎαα ααααααααα»αααααααΆ | αααααααααΌαα αααα ααααααΈααααααααααα αα·αααααααααα ααα αΆαα’αααα·αααΈ |
| αα»αααΆααααααΆα αα ααααα’αααα·αααΈ | α’αΆααααααα ααΆαααΆαα’αα»ααααααααΆαααΌααααααααΆαααααα | ααΆαααααΌαα αααααααΎαααα»ααααααα’αΆαααα·αααΆαααΎα α¬ααΆαααααΌαα αααααΆααααααΆα αα ααααα’αααα·αααΈ | α’αΆααααααα ααΆααααααα | αααααααΆαααααΆα αα αααααααααΆααααααΆαααα α¬αα»ααααα·ααΆα | αααααααα HVAC, ααααΏααααΆαααΈα, ααΆααααΌααααΎα, ααααααααααΆααααααααΊααααα’αΆαα·ααα |

ααααα·αααΎα’ααααααα»αααααααααα§αααααααΆαααααααΆαα½αααΉαααΆαααΆαααΆαααΎαα αααα ααΌαααΎα α§ααααααααααααααααΈαααααΉααα»αααΆααααΆα αα αααα. α§αααααααΆααα ααααα’αααα·αααΈ (Circuit breaker) αα·ααα»αααΆααααααΆα αα αααα (Isolating switch) αα·αααααααα»αααΆαααΌα ααααΆαααααα.
αα·αα·ααααααααΆα’αααα·αααΈα α ααα»α’αααΈααΆαααΆααααΌαααΆαα’αΆα αααα αΆαααΆαα αααΆααααΆαααΆααααααααΈ
αα αααα»αααααΌαααΆαα’αααα·αααΈ αα·αα·ααααααααΆααΆααΏαααααα αΆαααΈαα»αααΆαααΆαα αααΆααααΆααααααα α αααα ααααααα·αααα αα·αα·ααααααααΆααΆααααΆααα’αΆα αααααααα½ααα ααΆααααααααΆαααααΌαααΆα αα·αααΆαααααααααααααα»αα αα»α ααα»ααααααααααα·ααααα»αααΆαααΊαααααααΆαααΆαααααααααααΆα
| αα»αααΆαααααααα αΆααα ααΎααααΌαααΆα | α’αααΈααααα·αα·ααααααααΆαααα»αααααΆααΆαααααΆααα’ααα | αααααααΆαααααα»αααΆαααααΎαααΎα (Selection implication) |
|---|---|---|
| αα»αααΆαααααΆα αα αααα (Disconnector) / αα»αααΆααααα αααα (Isolating function) | ααΈααΆααααΎα (Open position) αααααααΌααααααΆαααααΆααααα αααααααααΆαααααα | αααααααααααΆααααΆααααα αααα αα»αααααΆααααα·ααααααααΆαααΆααααααΆαα/αααααααααα·ααααααΆααααΆααααα ααααααααα»ααααα |
| αα»αααΆαααΆαααα αααα | α§ααααααααααααΌαααΆααα ααΆα‘αΎααααααΆααααΆαα α¬αααααΆααααααααΈα’αααα·αααΈααααααααααααααααααΆαααααα | αα·αα·αααααΎαααααα·αα ααααααααα·ααααα·ααΆα αα·αααααααααααΆαααααΎααααΆαα |
| αα»αααΆααααααΆα αα αααα (Switch-disconnector) | α§αααααααααα½ααααα αΌαααααΆααΌααα»αααΆαααΆαααα αααα αα·ααα»αααΆαααααΆα αα αααα | αα·αα·αααααΎαααΆααααΆαααααα·α αα ααααΆαααΆαααα αααααααα»α αα·αααΆααααααααααααΆααααΆαααααΆα αα αααα |
| αα»αααΆααααααΆα αα ααααααααααα ααα»ααααΈα (Fuse-switch-disconnector) | αα»αααΆαααΆααα/ααααΆα αα αααα αα½ααααα αΌαααΆαα½αααΆαααΆαααΆααααα ααα»ααααΈα | αα·αα·αααααΎαααααααα ααα»ααααΈα ααΆααααααααααα½α αα·αααααα·ααααααααΆαααΆααα αααααααα»α |
| ααααααΈααααΎα | α§αααααααΆαααΆαααΆαααΆα αα αααααααααααααααααααα· | αα·αα·ααααααααααΆαααΆααα αααα (breaking capacity) α―αααΆααΆααα αααα (trip unit) αα·ααααααΆαααααΆααααΆαααααΆα αα αααα ααααα·αααΎααααΎααΆα§αααααααααΆα αα αααα (isolator) |

αααααααΆααΌαα ααα»αααααΆααΆααααααααα·αα·ααααααααΆααΆαααΆααααααΆαααα αααα»αααααααα’ααααααΆαα·α ααααΌαααααααααααααΎααΆαααααΆ βdisconnect switchβ αα αααααααΌαα±αααααα»ααααααααααααααΆααααΆ ααΎα§αααααααΆαααααααααΊααΆ disconnector, switch-disconnector, fused disconnect α¬ circuit breakerα.
ααΌαα ααα»αααααΆαααααΆααααααααααααααΌαααΆαααΆααα ααα‘α
ααΆαααΆααα ααα‘αααΎαα ααααΈαααααααΈα.
ααΈαα½α, αααααααααααααααΆααααΎααΆαααααααααααααΆα α―αααΆα IEC αα·αααΆααΆα‘α»αα’ααααααΆαα·ααΆα αααΎααααααααααΎ α§αααααααααΆα αα αααα αα·α α§αααααααααΆα αα αααα. α―αααΆααα α’αΆαααα·αααΆαααΎααααααααααΎ αα»αααΆααααααΆα αα αααα (Disconnect switch), αα»αααΆαααα»ααααα·ααΆα, α¬ αααααααΆαααααΆα α. α’αααααα‘αΎαααΆα αααΎαααααΎ α§αααααααΆααααααΆα α ααΆααΆααααα αα αααααααΆααααααααα ααΉαααααααα.
ααΈααΈα, αααα»αα αα»αααα·αααααααααα§αααααααααα½ααααα αΌααα»αααΆαααααααααααΆα ααα·ααααα½αα’αΆα ααααΌαααΆαααΆαααααααΆαα»αααΆααααααΆα αα αααα (isolator switch) ααα»αααααααααΉααα·ααααααααααααΆα’αΆα αααα αΆαααΆααΆαα·αααΆαα»αααΆααααααΆα αα ααααααααααααα»α (switch-disconnector) αααααΆααααααααΆαααΆααααααΆα αα ααααααααααααα»αααΆαααααααααααΆαααααΎααααΆαααααααΆααααααα.
ααΈααΈ, αααααααααα’ααααΆαααΆαααΌα ααααΆα’αΆα ααΆααααΆαααααααααΆαααααα»αααααΆααααΆααα ααααΆα αααααα·αααΈαα’αΆα ααΎααα ααααααααααΆαα ααΆααααα ααΌααααΎα ααα»αααααα½αα’αΆα ααΆα§αααααααααΆα αα αααααααααααΆααααα»α (off-load disconnector) ααααααααααα½ααααα’αΆα ααΆαα»αααΆααααααΆα αα ααααααααααααα»α (load-break switch-disconnector)α.

αααα αΎαααΆααΌαα ααα»ααααααα½αααααΉαααααΌααα·ααααααααΆααααααΆ βααΎααΆα α ααΆα’αααΈ?β αααααα αααα½αααααΉαααααΌαααΊα
ααΎα§ααααααααααααΌαααΆααααααααααα·ααααααΆααα’αα»ααααα ααααα’αααα·αααΈ ααα»α ααααααααααα»α αα·αααΆαααααα·α αα ααααΆαααααΌαα ααααααααα·αααΆ?
ααΎα’αααΈαα ααΆα§αααααααααΆα αα αααα (Isolator)?
α α§αααααααΆααααααΆα α ααΊααΆα§ααααααααααααΎαααααΆααααααΆα αααααααΈ α¬ααααΏαααα·ααααΆαα ααααΈαααααααΆααα ααΎααααΈα±ααααΆαααααΆαα’αΆα ααααΌαααΆαα’αα»ααααααααα»ααααα·ααΆαααΆααα»αα ααΆαααΆαα’αα»ααααααΆααααααα ααΆααααααααΆααααααΌααααΌααΆαα ααΆα’αΆα αααα αα ααΎα§αααααααααΆα αα αααααααααααΆαααααα»αααααααΆ αα»αααΆααααααΆα αα αααααααααααα·α α§αααααααααΆα αα αααα DC αααααΆααααααααααααΌα‘αΆ PV α¬αα»αααΆααααααΆα αα αααααααααααΎααΆαα»αααΆααααα.
α ααα»α ααααΆααααΊααΆ ααΆαααααΆα αα ααααααΊαααα αα ααΎααΈααΆααααΎα (open position). α α§αααααααααΆα αα ααααααααααΉαααααΌααα½αααααΌααααααααααΌαααΆααααααα αααΆααααΆαααααΆαααααααααααααααααα·αααααα»ααα αααααΎα α αΎαααΆαα½αααα’αΆα α αΆαααααααΆα α¬ααΆααΆαα»ααααα·ααΆαααΆααααααααΆααααααααααα αααααααααααΌαααΆααα»ααααα·ααΆαααααΆαααααΆαααΆαααΆαα.
αααααΆαααΆαααΆααααα αα·ααααα§αααααααΆααα’αααααα α ααΆα§αααααααααΆα αα ααααα’αααα·αααΈ (Isolator) αα»ααααααααααααααααΆααααΆαααΆααα αααααααααααααα»ααααααα α§αααααααααΆα αα αααααα½αα ααα½αααααΌαααααααΎαααΆαααΆααα»αααααΆααα αααααα αααα»αααααααΈααααΌαααΆαααΆααααααΆα ααααα§ααααααααααααααα½α ααΆααα αΎα ααΌα ααΆα§αααααααΆααααααααΈ (Circuit breaker) αα»αααΆααααα (Contactor) α¬α§αααααααΆααα αααααααα ααα»ααααΈα (Fuse-switch)α.
αααααΆααααΆαααααΎααααΆααα ααααααααΆαα (DC) ααααααααααααΆαααααΎαααΎαααΊααΆααααααΉααααΉαα α§αααααααααΆα αα αααα DC ααααΌαααααΆαααααα·αααα»α DC α αααα ααΆααααα ααααααα αα·αααααααααααΆαααααΎααααΆααααΆαααααααα ααααΌα’αααα·αααΈ DC αα·αααΆαα’αααααααααααααΈααΆαααααααΆααα ααα»α ααΌαααααΌα α ααααααααΆαα (AC) ααααα ααΌα ααααα§αααααααααΆα αα αααα AC αα·ααα½αααααΌαααΆααααααααΆα’αΆα ααααΎααααΆααααΆααααααΆααααααααααααΆααααααααΊααααα’αΆαα·ααα (PV) ααα α¬ααΆαα ααα αΆαα αααα DC α‘αΎαα αααααΆααααΆααααααααααααΆα DC/AC ααΆαααααααΈααααα ααΌαααΎα DC Isolator αααααΉα AC Isolator Switch.
ααΎα’αααΈαα ααΆα§αααααααααΆα αααααααΈ (Disconnector)?
αα½α α§αααααααααΆα αα αααα ααΊααΆααΆαααααααΌαααΆαααΆααααααααΆα IEC αααααΆααα§αααααααααααααααΌαααΆαααααΆα αα αααααα αααα»αααΈααΆααααΎαα αα½ααΆααΈα ααααααααααΆααΊαααααΎαα ααα»α ααααααααααααααα»ααααα·ααΆα αααααΆααααΈααααααΈααααΌαααΆαααΆααααααΆα αααΈαααααααΆαααα.
αααα»αααΆαααααΎααααΆαααααΆαααΉααααΉα α§αααααααααΆα αααααααΈ (Disconnector) ααΆααααααΆααΊααΆ α§αααααααααα·αα’αΆα ααΆααα αααααααααααααα»αααΆα (Off-load device). α ααΆαα·αααααΌαααΆααα ααΆα‘αΎαααΎααααΈααΆααα ααααααααα»αααααααΆ α¬α ααααααααααΆααααα α»α (Fault current) ααααα αα»αααααΆαααααααΉααα·αααααααα αα ααααααααααΆαααααΆαα αααΆααα’αααΈααααα·ααααααααΆααααα»αααΆαααΎα αα·ααα·αα ααααα.
ααΆααααα αααααααΆαααΆααααααΆαααα αααα»αα§αααααααααΌαα αααα (Switchgear) αα·αααΈαα·αα·ααΈααααΆαα ααΆαααΎαα§αααααααααΆα αααααααΈαα»ααααααααααααα αααααααα»αα αΌαα’αΆα αααααΎαα±ααααΆαααααΌα’αααα·αααΈαααααΆααααααααααΆαα ααΆαααΌα ααΆαααααΆαααααα αα·αααΆααααΆαααααα§αααααα αα αααα»αααααααααααΆα αααΎα ααααΆααααααΉαααααΌαααΊα
- ααααΎα§αααααααΆααα ααααα’αααα·αααΈ (Circuit breaker), αα»αααΆααααα (Contactor) α¬α§αααααααΆααααααΆα αααααα»α (Load-break device) ααΎααααΈααΆααααααΆα αα ααααα’αααα·αααΈα.
- ααΎαα§αααααααααΆα αα αααα (Disconnector) ααΎααααΈααΆααΆααΆαααααΆα αααααααααα’αααα·αααΈα.
- α’αα»ααααααΈαα·αα·ααΈα αΆαααα αααααααααΆαα αα·αα α»αααΈ ααΆααααααΌαααΆαααααΆαααα‘αΎαα.
ααΆαααααΆ Disconnector αα½αααΆαααααΌαααΆαααααΎαααα½αα±ααααΆααα Isolator ααα»αααααα αααα»αα―αααΆααα·ααααααα ααΆααΆααΆααααααΎααααα»αααΆααααααΉαααΌα ααΆααααααα αα»αααΆαααααΆα αα ααααααΆα’αΆαα·ααΆα αα»αααΆαααααΌαα ααααααααΎααΆααααααα»αααααΈαααααΆαααΆααααααααααα·αααααΉαααααΌαααα»ααααα.
ααΎα’αααΈαα ααΆ Switch-Disconnector?
αα½α α§αααααααααΆα αα αααα αα½ααααα αΌααα»αααΆαααΈαα
- αα»αααΆαααααΌαα ααααα ααΆα’αΆα ααααΎααΆααααααΆαα αα·αααΆααααααΆα αα ααααα’αααα·αααΈααααααααααααααααααΆαααααα
- αα»αααΆαααΆααααααΆα α (disconnector function): ααΆαααααααΌαααΆαααααΆα αα ααααα’αααα·αααΈαα αααααΎα
αααααΊααΆα§ααααααααα’αααααα‘αΎαααΌα’αααα·αααΈααΆαα αααΎαααααΌαααΆα αα ααααα½αααα ααααΆααα»αααΆαααααααααΆααααΌαααααΆ α¬ααΌα ααα αΆαααΆαααα’αααα·αααΈααααααα»αααΆαα ααΆα’αΆα ααααΌαααΆαααααΎααΎααααΈαα·α-ααΎαααααααΈαααα»αα’αα‘α»ααααααααα·ααααα·ααΆαααααααΆ αα·ααααααααΌαα ααα»α ααααΆα αα αααααααααΆααααΆαααααΆα αααααΆαααααααααααΆαααααααααΌααααααααΆαααααΎαααΎαααααΌαααααΆααΉαααααα·αααααα»αα.
ααααΆααααααΆααααΊ ααααααααααααααααααΆαααααα. αα»αααΆααααΆααααααΆα α (switch-disconnector) αα·αααααα»ααααααααααααααααΆαααααααααααα»αααΆααα’αααααααα αααααΉααα·αααααααα αα αααααααααααΆαα½αααααααΌαααΆααααα½ααα·αα·ααααααααΆααα
- ααα»αααααα·ααααα·ααΆααααααΆαααΆαααααα
- α ααααααααα·ααααα·ααΆααααααΆαααΆαααααα
- ααααααααααΆαααααΎααααΆαα (utilization category) ααΌα ααΆ AC-21, AC-22, AC-23, DC-21, DC-22 α¬ DC-23
- αααααααΆααααα»αααΆαααΆα αα ααααα’αααα·αααΈαααα»αααααΈααααα αααα (Short-circuit making capacity) αααα»αααααΈαααααΆααααααα
- ααααα·αααααααααΉαα αααααααα (Conditional short-circuit current rating) ααΆαα½αα ααα»ααααΈα α¬α§αααααααΆααα αααααα αααααααΆαααΎ (Upstream)
- α ααα½ααααΌα αα·αααΆααααα αααααααααααΆααααααΆα αααααααΊα (Neutral)
- αααααααΆααααα»αααΆαααΆααααααΆα αα αααααααααΆαααα»ααααα·ααΆα (Suitability for isolation)
αααααΆααααΌα’αααα·αααΈααααααα»αααΆα αααααΊααΆααΆααα»αααααΆααΆααααααααααα»αα α§αααααααΆααααααΆα α (Disconnector) ααααΎαααααΆααααΆααααααΆα αα αααα α ααααα§αααααααΆααααααΆα αααααααααααΈα (Switch-disconnector) ααααΎαααααΆααααΆααααΆαααΎα-αα·α αα·αααΆααααααΆα αα ααααα.
ααΎα’αααΈαα ααΆ Load Break Switch?
αα½α αα»αααΆαααααααααααα»α ααΊααΆααααΈααααααααΌαααΆααα ααΆα‘αΎαααΎααααΈααΎα αα·ααα·αα αααααααα»αααααααΆα ααΆααααααααααΌαααΆαααααΎααααΆααααΌαα ααΆαααααα»αααααααααα ααα αΆαααΆαααααααααα»αααΆα αα·αααααααα»αααααα ααα»αααααα·αααααΌαα ααα‘αααααα·αααααααα»αααΆααααΈααααα‘αΎαα αα αααα»αααΌα’αααα·αααΈααααααα»αααΆα ααΆαααααΎαααΎαα§ααααααααααααΌαααΆααα·ααΆααααΆααΆααΌαα ααΆααααααααΆα IEC 60947-3α α αααααα αααα»αααααααααααααααα»αααααα Load break switch αα·α Disconnector αααα·ααααα»ααααα»αα§ααααααααααααααΆ αααααΆααααααΌαααΆααα»αααααΆααΎααααααααΆαα’ααΈααΌα‘αα ααΆαααααΆαααααααααααα»ααααα·ααΆα (Interlocking) ααΆαα α»αααΈ αα·ααααααΌαααΆααααααα.
α ααα»α ααααΆαααα Load break switch ααΊαααααααΆααααα»αααΆαααΆααααααΆα αα ααααααααα·ααααα·ααΆαααααααΆα ααΆαα·αααΌα ααααΆαα ααΉαα§αααααααΆααα ααααααααααααααααα· (Circuit breaker) αααααα ααΆααΌαα Load break switch αα·ααααααααΆαααΆαααΆαααΎαα ααα»α (Overload) α¬ααΆαααΆαααΆαααααα αααα (Short-circuit) αααααααααααααααα·αα ααΎααααααααΆααΆααααααα½αααα§ααααααααααααΆααααΆαα½αα ααα»ααααΈα α¬α§αααααααΆαααΆαααααααααα.
ααααΈααααΎααααΆααααααααΆααΆαααΌα ααΆα
- ααΆαααααΌαααααααααααααααα (feeder switching)
- ααΆαααααΌααααααααααΌ (transformer switching)
- ααΆαααααΌααααααα αΌααα (main incoming switching)
- ααΆααααα αααΆααααααααααα»αααααα (manual load transfer arrangements)
- ααααααΈα ααα αΆαααααααααΌαα±ααααΆαααΆαααααΌαα ααααααααα»αααααααΆ
αα αααα»αααΆαααααΎαααΎαα§αααααααααααα»αααΆαααΆααααααααΆα IEC αααααααΆααααα»αααΆαααααΌαααααα»αααααΌαααΆαααααΆαααααΆααααΆααΌαα αα ααΉαααααααααααΆαααααΎααααΆαα (utilization categories)α α§ααΆα ααα AC-21 ααααΌαααΆαααααΆαααααΆααααΆαα½αααΉαααααα»αααααααααα (resistive loads), AC-22 ααΆαα½αααΉαααααα»αα αααα»ααααΆαααααα·αα’αΆαααα»α ααα (mixed resistive and inductive loads) αα·α AC-23 ααΆαα½αααΉαααΆαααααΌαααααα»ααααΌααα α¬ααααα»ααααααΆαα’αΆαααα»α ααααααααα ααααα·αααα»ααα·αα ααααααΆααααΆααααααΌαααααα’ααααΎαααααΉααα·αααααααα αα αααααααααααα·αααα.
ααΎα’αααΈαα ααΆαα»αααΆααααααΆα αα αααα (Disconnect Switch)?
αα½α αα»αααΆααααααΆα αα αααα (Disconnect switch) ααΊααΆααΆαααααΌαα αααααααΌαααΆαααααΎααΆαα·ααααα αααα»αα’αΆαααα·αααΆαααΎα αα·αααΆααΆα’ααααααΆαα·ααΌαα α ααΆααααααΆααΆααΆααααααΆααΆα§ααααααααααααΆα αα ααααα’αααα·αααΈαααααΆααααΆαααααΆα ααΆααα½ααα»α ααΆαα αΌαααααΎαααα»αααααΈαααααΆαα α¬ααΆαααααΆα αα αααααα ααΉαααααααα.
ααα»ααααααΆαααααααα·αααΆααααααΆαααααα’α·ααααααααααΆααααααααα½αα―ααααααα αα»αααΆααααααΆα αα αααα (Disconnect switch) α’αΆα ααΆα
- ααααααααΆαα ααα»ααααΈα α¬ααααΆαα ααα»ααααΈα
- ααααααααΆααααααΆα ααααααααααα»α (load-break) α¬αα·αα’αΆα ααΆααααααΆα ααααααααααα»αααΆα (non-load-break)
- ααααααααααΎαααααΆααααα ααααααααΆαα (AC) α¬ααΆαααααα·ααααααΆααα ααααααααΆαα (DC)
- ααααααααΆααααα’ααααΆαααΆα (enclosed) α¬ααααααααΎαα αα (open type)
- ααααααααααα·ααααα·ααΆαααααα α¬ααααα·ααααα·ααΆαααααααΌααα
- ααααααααααααααα α¬αα·ααααααααααααΆααααΆαααααΎααααΆαααα α αααα αΌαααααΆαααα α¬ααΆαααααΆα αα ααααα§ααααααα ααΉααααααα αααα’αΆααααααα ααΆαααααααΆα αα·αααΆαα α»ααααααΈαα αα ααααα
αααααΆααα·αααα βαα»αααΆααααααΆα αα ααααβ (disconnect switch) ααΊααΆααααΆααααααα αΆαααΈαα»αααΆαα αααΎαααΆαααΆαα αΆααααααΆααααΆααααααααα αα αααααα αααΆααααΆααα ααΌααα·αα·αααααΎαααααα·αααα»α/α αααα (ratings) αα·ααααααΆαααααΆαααααααααΆαααΆαα·α αα αα»αααΉαααααα·ααααΆαααΆααΆα’αΆα ααααΎα’αααΈααΆαα.
αααααΆαααααααααααααΆαααααΎαααΎααααααΆααααααα ααΌαααΎα αα»αααΆααααααΆα αα ααααααααααααΆαα ααα»ααααΈα αα·αααααααααααΆαα ααα»ααααΈα αα·α ααΆααα»αααααΆαααΆαα§αααααααΆααα ααα»ααααΈα (Fuse Holder) αα·αα§αααααααΆααααααΆα αα ααα»ααααΈα (Fuse Switch Disconnector).
ααΆααα»αααααΆααααΆααααα αααα»αααΆααΆααα αα ααααααααα½α
| α ααα»α ααααΆαααααΎαααΎα | α§αααααααααΆα αα ααααα’αααα·αααΈ / α§αααααααΆααααααΆα α (Isolator) | αα»αααΆααααααΆα αα αααα (Switch-disconnector) | αα»αααΆααααΆααααααα»α (Load break switch) | ααααααΈααααΎα |
|---|---|---|---|---|
| αα½ααΆααΈα αααα | ααΆαααΆααα±αααα ααΆα ααααα‘αα | ααΆααα·α-ααΎα + ααΆαααααΆα αα αααα | ααΆαααΆααααααΆα αα αααααααα»α (Load current switching) | ααΆαααΆαααΆα + ααΆαααΆααααααΆα αα αααα |
| ααΆαααΆααααααΆα αα αααααααα»αααααααΆ | αα·αα’αΆα ααααΎααΆααα ααΎααααααααΆαααΆααααααΆααααααα·ααααααααΆα (rated) | ααΆα αααα»αααααα·αααααα | ααΆα αααα»αααααα·αααααα | ααΆα αααα»αααααα·αααααα |
| ααΆαααΆααααααΆα αα αααααααα (Fault current) | ααααΆαααΆα | αα ααΎααααααααΆαααΆααααααααααα½α/ααααααααααΆαααα‘αΎα | αα ααΎααααααααΆαααΆαααΆαααΆαααΆααααΆαα | ααΆα αα αΌαααααααααααΆαααΆααααααΆα α (Breaking capacity) |
| αα»αααΆαααΆααααααΆα ααααααααααααααααα· | ααααΆαααΆα | ααααΆαααΆα | ααααΆαααΆα | ααΆα |
| αα»αααΆαααΆα ααααα‘αα | ααΆα ααααα·αααΎααΆαααααααααααΆααααΆαααααΆα αα αααα (Isolation) | ααΆα | α’αΆαααααααΎααα·ααα | αα»αααααΆααααΆαααΆααααααΆαα/αααααααααα·ααααααΆαααα»αααΆαααααΆα αα αααα (Isolation) |
| ααα·αααααααααΆαααΌαα | IEC 60947-3 | IEC 60947-3 | IEC 60947-3 α¬αααααααΆαααααα·αααααααα»ααααααααα | IEC 60947-2, IEC 60898-1, UL 489 ααΆααΎα. |
| α αΆαα·αααα αααααααα»αααΆαααααΎαααΎα | ααΆαααααΆα αα αααααα αααααΆααααα»αααααα»α (Opening under load) | ααααααααΆαααααΎααααΆαααα»α | ααΆαα αΆαααα»αααΆααΆα§αααααααΆαααΆαααΆαααααα ααααααααΈ (Short-circuit protection) | ααΆαα αΆαααα»αα§αααααααΆαααΆαααΆααΆα§αααααααααΆα αα αααααααα’αΆα ααΎαααΎααααααααα (Visible isolation) |
αααααΆααΌαα ααα»αααα§αααααααΆααααααΆα α (switch-disconnector) αα·αα§αααααααΆααααααΎαααααααααααααα· (circuit breaker) αααααααααΎααααΆαααα½αααααΆαα αααα»αααΌα’αααα·αααΈα§ααααΆα ααααα α§αααααααΆααααααΎαααααααααααααα·ααΆααα½ααΆααΈααΆαααΆαα ααααααΎαα ααα»α α ααααα§αααααααΆααααααΆα αααΆααα½ααΆααΈαααααΆαααα·α-ααΎαααααα αα·αααΆαααααΆα αααααααααα’αααα·αααΈ α’αΆααααααα ααΆαααΆααα ααΆα.
ααΆαααααααααΆααααααααΆα IEC ααΎαααααΉαα’αΆαααα·αααΆαααΎα
ααΆαααααααααΆααααααααΆα IEC αα·αα’αΆαααα·αααΆαααΎα αα·ααααααααΆααααααΌα ααααΆαα½ααααααΉααα½ααααααα.
| ααααααα·α | ααΆααααααααααΎααΆααΌαα ααΆααααααααΆα IEC | ααΆααααααααααΎααΆααΌαα ααΆααααααααΆαα’αΆαααα·αααΆαααΎα/ααΌαα | ααΆαααααααΆαααΆααααααα |
|---|---|---|---|
| ααΆαααααΆα ααααααααααααα½ααα»α | αα»αααΆααααααΆα αα αααα (Disconnector) | αα»αααΆααααααΆα αα αααα / αα»αααΆαααααααΆααααααΆα ααααααααα (Isolating switch) | αααααΎαα ααα»α ααααΆα αα ααααα’αααα·αααΈ ααΆααααααΆαα αααα»αααααΆαααΆαααααΆαααααα»α |
| ααΆααα·α-ααΎα + ααΆαααααΆα αα αααα | αα»αααΆααααααΆα αα αααα (Switch-disconnector) | αα»αααΆααααααΆα αα αααααααααααααα»α / αα»αααΆααααααΆα αα αααααααααααΌαααΆαααααααααααΆααααααα»α | α’αΆα ααααΌαααααΆα αααααα»α αα·αααααΆα αα ααααααΆα ααααα·αααΎααΆαααΆααααααααααα·αααααΉαααααΌα |
| ααΆαααααΌααααα»α | αα»αααΆαα, αα»αααΆααααααΆα αα αααααααααααααα»α | αα»αααΆααααΆααααααα»α (Load break switch) | αα·α/ααΎαα ααααα’αααα·αααΈααααααΆ |
| ααΆαααΆαααΆα | ααααααΈααααΎα | ααααααΈααααΎα | ααΆααααααΆα αα ααααααααααΆαααα»αααααααααΈ (Fault current) αααα»αααααα·ααααααΆαααααα |
| α ααα»ααααΈα + ααΆαααααΆα αα αααα/ααΆαααααΌαααααΆα α | αα»αααΆααααααΆα αα ααααααααααα ααα»ααααΈα (Fuse-switch-disconnector) | αα»αααΆααααααΆα αα ααααααααααααΆαα ααα»ααααΈα | ααΆαααΆαααΆααααα ααα»ααααΈα ααΌααα½αααΉααα»αααΆαααααΆα αα αααα/αα·αααΎα α’αΆααααααα ααΆαααΆααα ααΆ |
αααααΆααααααααα’ααααααΆαα· ααΌααααααΆαααΆαααααααααΆααααα αα αααααααΆααααααααααααα ααααααααααΆαααααα»ααααααααααααααααΆ βisolatorβ α’αΆα ααΆααααααΆααΆα§αααααααααΆα αα αααααα»αααααΆααα αααα»ααααααααα½α α αΎαα’αΆα ααΆααααααΆααΆαα»αααΆααααααΆα αα αααααααααααααα»α (load-break switch-disconnector) αα αααα»ααααααααα½ααααα αααααΉααα·αααααααα αα ααααα (datasheet) αα·ααααααααΆααααααΆααααααα ααΊααΆα―αααΆααααα α»ααααααα.
ααααααααααΆαααααΎααααΆαα (Utilization Categories)α ααΌαα ααα»αααααΆααΆαααΆααααααΆαα
ααΆααα·αααΎαααααα»ααα·αααααα·αααααΎαααααΆααα’αααα (amperes) αααααα ααααα»ααααααα resistive 100A αα·αααααα»ααααααααααΌααα 100A αα·αααααΎα±αααααααΆαααααααααΆααααααα’αααα·αααΈ (contacts) αααα»αααααα·αααΌα ααααΆαααααα ααααα»ααααααα inductive αααααΎαα±ααααΆαααααΆααααΎαα’αααα·αααΈ (arcing) ααΆααααααααΆαααα αααααααΆα αα ααααα.
αααααΆααα§ααααααα·αααΎαα ααααααΆαααΆααααααααΆα IEC ααααααααααΆαααααΎααααΆαααα½ααααααααΈααΆαααααα·α αα ααααΆααα·αααΎααααααΆαααααααα»αα α§ααΆα αααααΌαα αα½αααΆαα
| αααααα | α’ααααααααΌαα | αααααα αααΆαααΆααααααα |
|---|---|---|
| AC-20 / DC-20 | αααααΆαααα·αααααΆαααααααααΆααααα»ααααααααα | αα·αααααΌαααΆααα ααΆα‘αΎααααααΆααααΆαααααΆα αααααα»αααααααΆααααα |
| AC-21 / DC-21 | ααααα»ααααααα Resistive α¬ααααα»ααααααΆααααααα Inductive ααααα·α ααααα½α | ααΆααα·αααΎαααααα»αααΌαα αααααΆαααααα·αααααΆαααΆα |
| AC-22 / DC-22 | ααααα»α resistive αα·α inductive α αααα»α | ααΆααααααΌαααΆααααααααΆα AC-21/DC-21 |
| AC-23 / DC-23 | ααααα»ααααααααααΌααα α¬ααααα»ααααααΆααααααα Inductive ααααα | ααΆαααααα·αααααΆααααα»αααΆααα·αααΎαααααα; ααααΌαααααΎαααΎαααααααα»ααααααααα |

αααααΊααΆααα α»αααΌαα αααα»ααα½ααααα»αααΆααα·ααααααΆααα α§ααααααα½αα’αΆα ααΆαααααα·αα ααααααααα ααααα ααα»ααααααΆαα·αααΆααααααΆααΆα’αΆα ααΆααααααΆα αα ααααα αΆααααααΎαααααααααααααΌααα α¬ααααααΈ DC αααααΆαα’αΆαααα»α αααα»αααΆααααααααααααααααα·αααααα.
ααΎα’ααααα½αααααΎα§αααααα’αααΈ?
ααααΎα§αααααααΆααααααΆα α (disconnector) α¬α§αααααααααΆα αα αααα (isolator) αα ααααααααααααΈααααΌαααΆααα·αααΎααα αααααααααααα
ααααΎαααΎαα§αααααααααα ααααααααΆααααΆααααααααΌαααΆααααααααΌαα ααα»α ααααΆα αα αααααααααααααα»ααααα·ααΆα αααααΆααααΈα§αααααααααααααααΆαααΆααααααΆα αα αααααα½α α αΎαα α§ααΆα αααααααααΆαα½αααΆα α ααα»α ααααΆα αα αααααααααΆααααΆαααααΆααα αααα»αααΌα’αααα·αααΈ α¬αααααααααααααααΆααααααΆαααααα·ααααα·ααααΌαααΆααααααααααα.
ααααΎα§αααααααΆααααααΆα α (switch-disconnector) αα ααααααααΌα’αααα·αααΈααααΌαααΆαααΆααα·αααΎαααααα αα·αααΆαααααΆα αα ααααα
ααααΎαααΎαα§αααααααααααααΆαααααααα·ααΈαα·αααΎααα αα·αααΌαααααΆαααααΆαααααααα»αααΆαααΆα αααΎα ααααα·αααΎααααααααααΆαααααΎααααΆαα αα·αααααα·αα ααααααααΌαααααΆααΉαααααα»αα αααααΆααΏααααΆαααααΎαααααα’αααα»ααααααΆααααΌα’αααα·αααΈα§ααααΆα αααα ααααΏαα ααα αα·αααΌα ααα αΆαα αααααααααααΌαααΆαααααΆαααα ααΉαααααααα.
ααααΎα§αααααααΆααααααΆα ααααααααααα»α (load break switch) αα ααααααα ααααααααα»αααααααΆααααΌαααααααΎααΆααα·αααΎαα
ααααΎαααΎααααααΎαααααα αααααΆαααΆαααααα·ααααα·ααΆαααΊααΎααααΈαα·αααΎαα αααααααα»αααααααΆ ααΌα ααΆαααααααααΌαααΆααα (feeders) α¬ααααααΈαααααααααααα ααΌααααααΆααααΆααΎααα·ααααααααΆααα»αααΆαααααΆα αα αααα (isolation) αααα¬αα ααααα·αααΎααααΌαααΆαααΆαααααΆα αα αααααααααΆααααααΆαα.
ααααΎα§αααααααΆααααααααΈ (circuit breaker) αα ααααααααααΌαααΆαααΆαααΆαααΆααααααααααααααααα·α
ααααΎαααΎαα§αααααααΆααααααααΈαα ααααααα§αααααααααΌαααααααΆα ααααααααααααααααα·αα αααααΆαααΆααααα»αααΎαααααα·α (overload) α¬ααΆαα ααααααααααΆααααααααΈααααΈ (short-circuit fault current)α αα»ααααα½αα§αααααααΆααααααααΈααααα»αααΆααααααΆα αα αααα (switch-disconnector) ααΎααααααααΆαα§αααααααΆαααΆααααααααααααααααααα.
ααααΎα§ααααααααααΆαααααα·αααα»α DC αααααΆααααααααααααΆααααααααΊααααα’αΆαα·ααα (PV) ααα αα·αααααααααα ααα αΆαα αααα DCα
αααααααα DC ααΆαααΆαααΆαααα α·ααααα»αααΆαααα·αααα ααΆααααααααΆαα ααα»α ααΌαααααα ααααααααααΆαα· (natural current zero crossing) ααααΎα±ααααΆαααααΆα αααααΌα’αααα·αααΈ (arc interruption) αααα»ααααααααα DC ααΆαααααα·ααΆαα αααααΆαααααααααα PV αα·αααα ααΌααα·αα·αααααΎαααααα·αααα»α DC ααΆααααααΆαααααααα (pole wiring) αααΌα (polarity) ααααααααααΆαααααΎααααΆαα αα·αααΆααΎα§ααααααααααααΌαααΆαααΆαααααααααααΆαααααααα·ααΈααΆααααΆααααααααα¬ααα αααααΆααααα·ααααΆααααΆαααα PV ααΌαααΎα ααΎ DC Isolator Switch ααΊααΆα’αααΈ? αα·α ααααα’αΆαααααα·αααΆαααααααααααα»αααΆααααααΆα αα αααα DC (DC Isolator Switch).
ααα α»αααΌαα αααα»αααΆαααααΎαααΎα
ααα α»αααΈ α‘α ααΆααααααααΆα§αααααααααΆα αα αααα (isolator) αααααααααααα’αΆα ααααΆα αα αααααααα»α (load current) ααΆα
αααααΊααΆααΆααααα ααα‘ααααααααααααΆαααααα»αα α§αααααααααΆα αα αααααα½αα ααα½αααααΌαααΆααα ααΆα‘αΎααααααΆααααααααα·ααααα·ααΆααα αααααααΆαα αααααααα»α (off-load) ααα»αααααα ααααα·αααΎααααΌαααΆαααΆαααααΆα αα αααααααα»α ααΌαααααΎαααΎααα»αααΆααααααΆα αα αααα (switch-disconnector) α¬αα»αααΆααααααΆα αα αααααααα»α (load break switch) αααααΆαααααα·αααΆααααααααααΉαααααΌαα.
ααα α»αααΈ α’α ααΆααααα ααα‘αααΆα§αααααααΆααααααΆα αα ααααα’αααα·αααΈ (Disconnect switch) ααΆα§αααααααΆααααααΆα ααααααααααααααααα· (Circuit breaker)
α§αααααααΆααααααΆα αα ααααα’αααα·αααΈα’αΆα αααααααΌαα ααα»α ααΆααααααΆα ααααααααααα»ααααα·ααΆα ααα»ααααααΆααΌαα ααΆαα·ααααααααΌαααΆαααΆαααΆαααΎαα ααα»α (Overload) α¬ααΆαααΆαααΆαααΆαααααα ααααααααΈ (Short-circuit) αααααααααααααααα·α‘αΎαα ααΆαααΆαααΆαααααΌαααααααααααα ααα»ααααΈα (Fuse) α§αααααααΆααααααΆα ααααααααααααααααα· (Circuit breaker) α¬α§αααααααΆαααΆααααααΆααααα ααααααααααα½αααααΆα.
ααα α»αααΈ α£α ααΆααα·αα·αααααΎαααααΎααααα·αα ααααα’αααα·αααΈ (Current rating) ααα»ααααα
ααααα·αα ααααα’αααα·αααΈαααα½ααα»ααα·ααααααααααΆαααααααα α§ααααααααα½αα’αΆα ααΆαααααα·αααΆαααααααα»ααααααΆα’αΆαααααααΎααααααααΆαααΆαααΌα ααΆ AC-21, AC-22, AC-23, DC-21, DC-22 α¬ DC-23α ααΌαα’αΆαααααααααααΆαααααΎααααΆαα (Utilization category) ααΆαα·α αα α.
ααα α»αααΈ α€α ααΆααα·αα’αΎααΎααΉαααΆααααααααααα½αααΆαααααα ααααααααΈ (Short-circuit coordination)
α§αααααααΆααααααΆα αα αααα (Switch-disconnectors) αα·αα§αααααααΆααααααΆα αααααα»α (Load break switches) ααΆααΏααααααΌαααΆαααααΎααααΆαααα½αααΆαα½αα ααα»ααααΈα α¬α§αααααααΆααααααΆα ααααααααααααααααα·ααααα ααΆαααΎα ααΌααα·αα·αααααΎαααααα·αααααΆαααααα ααααααααΈααΆααααααααα (Conditional short-circuit ratings) αα·ααααααΌαααΆααααααααααα½ααα αααα»ααααααΉααα·αααααααα αα αααααα.
ααα α»αααΈ α₯α ααΆαααααΎααααΆααααααα·αααΆαααααα AC αααααΆααααααααΈ DC
ααααα·αααΆααααααααααΆαααΆααααααΆα αααααα»α AC αα·αα’αΆα α’αα»αααααααααααααααααααα·αα ααΎ DC ααΆαααα ααΆαααΆααααααΆα αα αααα DC ααααΌαααααΆαααΆαααΆααααααααΆααααΆαα αα·ααααααΆααααααααΆαααααΆααααΆαααααα’αααααα·αα.
ααα α»αααΈ α¦α ααΆααααααααΆααααΆαααααααΎαααΎαααΆααααααΆααααΆααααααα’αααα·αααΈααααΌαααΆαααααΆα αα αα
ααααΆααααααααααααα·α α¬α§ααααααααααΆααΆααααα αα·ααααααΆααααααΆααααΆααααααα’αααα·αααΈααααΌαααΆαααααΆα αα αααααααΎαααΎααααααα ααααα·αααΎααΆαααΆαα±ααααΆαααΆαααααΆα αα αααααααα’αΆα ααΎαααΎα α¬ααΆααααα αΆαααΈααααΆαααΆαααααΆααααααα αααΆααααΆαα ααΌααααααααααΆααααΎαα ααΆααααααααααα·ααα αα·ααααααΆαααααΆααααΆααααααααΆαα.
αααααΈαααα½ααα·αα·ααααααααΆααααΆαααααΎαααΎααααααΆαααα·ααααα αα·αα’ααααα·α
αα»ααααααααααααααααα αα αααααααα§αααααααααΆα αα αααα (Isolator), α§αααααααααΆα α (Disconnector), αα»αααΆααααααΆα αα αααα (Switch-disconnector), αα»αααΆααααΆααααααα»α (Load break switch) α¬αα»αααΆααααααΆα α (Disconnect switch) ααΌααααααΆααα
| αα·αα·ααα | α’αααΈαααααααΌααααααααααΆαα |
|---|---|
| αααααααααααααα | AC α¬ DC |
| ααα»ααααααΆαααΆαααααα | ααααΌαααααααΌααααααΉαααα»ααααααααα αα·αααΆααααα ααααααα (Pole arrangement) |
| α ααααααααα·ααααα·ααΆααααααΆαααααα (Rated operational current) | ααααΌαααααααΌααααααΉαα αααααααα»ααααααααααααααααΆαααΆαααααΉαααααΌα |
| ααααααααααΆαααααΎααααΆαα | AC-20/21/22/23 α¬ DC-20/21/22/23 ααΆαααΆαα’αα»ααααααΆααααααα |
| αα»αααΆαααΆα ααααα‘αα | α§αααααααααΌααααααααααααααΆααααΆαααααΆα αα ααααα’αααα·αααΈ ααααα·αααΎααααΎαααααΆαααα»ααααα·ααΆααααα»αααΆαααααΆα |
| ααΆαααααΆα αααααα»α | αααααΌαα±ααααΆαααααα·αααΎα§αααααααΉαααααΌαααΎααα αααααα ααααααααα»αααααααΆ |
| ααΆααααααααααα½ααααααΆαααΆαααααα ααααααααΈ (Short-circuit) | α ααα»ααααΈα/α§αααααααΆααα αααααα αααααααΆαααΎ (Upstream) αα·αααααα·ααααααααααααααααααΌααααααα½ααα·αα·ααα |
| α ααα½ααααΌα | ααΆααααα αααααΆααααΆα (Phase) ααααα’ααααΆααααΉα (Neutral) αα·ααααΌα DC ααααΌαααααααΌαααααΆααΉαααΆααα ααΆααααααΈ |
| ααααααααααααΆαα αΆαααααα»ααααα·ααΆα | α αΆαααΆα ααααααΆαααααααα·ααΈα αΆαααααα»ααααα·ααΆααααα»ααααααααΆα |
| ααααα·αααΆαααΆααααααααα’ααα§ααααα (Enclosure rating) | αααα»ααααα/αααα αααα, ααΌααΈ, ααααΎα, ααΆααααααΈ UV αα·αααα·ααααΆαααααΆαααα‘αΎα |
| αααααααΆα αα·ααα·ααααΆαααααα | ααααΌαααααααααΆααααααΌαααΆααααααααα ααΈααααΆα αα·αααΆαα’αα»ααα |

αααααΆααααΆαααΆααααααααα·ααααααααΆααααααΉα VIOX ααΌαααΎα αα»αααΆααααΆα ααααα‘αα, Switch Disconnector, αα·α αααΆαααΈαααα»ααααΌα αααααα.
αααα½ααααα½αααΉαααΆαα
ααΎαααα»αα’αΆα ααααΎα§αααααααΆααααααΆα αα αααααααααα AC-22 αααααΆαααααααααα VFD bypass ααΆααααα¬αα?
αα»ααααααα α α·ααααααααα’ααααΎ AC-22 αααα½ααα»αα ααααααΈ bypass ααααα§ααααααααααΆααααΏααααΌααα (VFD) α’αΆα ααΆαααααααααΉαα₯αα·ααΆααααααααα»ααααΌααα, α αααααααα½α (inrush), ααΆαααααΆααααααΆαααααααααααα»ααααα·ααΆα (interlocking) αα·αααΆααααααααααα½αα ααααααααααΆααααααααΈααααΈαα αααααααΆαααΎα ααΌααα·αα·αααααΎαααααΆααααΆαααααΆαααααΎααααΆαα, ααααααααααΆαααααΎααααΆαα, ααΆαααααα·α αα αααααααΌααα αα·αα’αα»ααΆαααααααα’αααααα·ααααααΆαααααααααα bypassα ααΆαααααα·α αα ααααΆαααααΌαα αααααααααΆααααααΉααααΌαααααΆα αααΎα ααΆαααΆαα±ααααΆαααααα·αααΆαααααααααααααΆαααΆαααααΎααααΆααααααα»αα αααα»αααααααΆα.
ααΎ AC-23 αααααα αΆαααΆα ααααααΆααααααααΈαααΌααααααα¬αα?
αα·ααααααΆαααααααααα ααα»αααααααΌααα αα·αααααα»ααααααΆαα’αΆαααα»α αααα»ααααααααΆααααααΌαααΆααααααααΆαααααα»ααααααα (resistive loads)α ααααα·αααΎα§αααααααΉαααααΎααΆααααααΆαα α¬ααΆααααααΆα αα αααααααΌααααααααααΆαα αααα’αΆα ααΉαααααΌαααΆαααααα·α AC-23 α¬ααααα·ααααααααΆααααααΆαααααΌαααααααααααααααααα»αα αα»αααα·αααααααααα ααααα·αααΎα αααααααΌαααααααΌαααΆαααααΌαααααα»αααΆααααα (contactor) α αΎαα§αααααααααΆα αα ααααααααΌαααΆαααΎααααα αααααααΆαααααα»αααα»ααααα αααααΌαααΆαα’αΆα ααΉααα»αααααΆα.
ααΎαα»αααΆααααααΆα αα αααα (switch-disconnector) α’αΆα αααα½αα§αααααααΆααα αααα (circuit breaker) αα αααα»αααααΆαααααααΆααΆααααα¬αα?
ααΆα αα»αααααΆααααΆαα§αααααααΆαααΆααα½αααααααααΆαααααα·αααααΉαααααΌααααααααΆαααΆαααΆαααΎαααααα»α αα·αααΆαααααα ααααααααΈα αα»αααΆααααααΆα αα ααααα’αΆα ααααΌα αα·αααααΆα αα ααααααΆα ααα»ααααααΆαα·αααΆααα αααααααααααααααααααα·ααΌα α§αααααααΆααα αααα (circuit breaker) αααααα.
α ααα»α’αααΈααΆαααΆααααΌαααΆααααααααα»ααααα αΆαααΈαα»αααΆααααααΆα αα αααα (disconnect switch) ααα»αααααααααΈαααααΆαα (BOM) αααααΆααααΆααΆαα»αααΆααααααΆα αα αααα (switch-disconnector)?
αααααΆααΏαααααααΆαα αααα»αααααααα’ααααααΆαα·α βDisconnect switchβ α’αΆα ααααΌαααΆαααααΎααΆααααΆααααααΆαααααΆαααα»αααΆααα ααΎααααΌαααΆα αααααααααα§αααααααααα·αααααΌαααΆααααααααΆααΆ switch-disconnector ααΎααααΈααΆααΆααΆααααΆαααααΌαααααα»α αα·αααΆαααααΆα αα ααααα αααααΈαααααΆαααα½αααα’αα»ααααααΆαααααα·ααααααααΌαααΆα αα·ααααααααΉααααααααα α αααα αα ααΎααααΌαααΆααααααα.
ααΎαααα»αα’αΆα ααααΎαα»αααΆααααααΆα αααααα»α AC αααααΆαα DC ααΆααααα¬αα?
αα·αα’αΆα αα αα»αααααΆααα§ααααααααααααΌαααΆαααααααααΆαα αααΆαααααααΆααααααΎααΆαα½α DC αα ααα»α α αααα ααΆαααααααα ααΆαααααααααααΌα αα·ααααααα·ααΈαααααααΌαααΆαα ααΆαααααΌαα αααα DC ααΆαααΆααααα»αααααΆαααΆααααααααααΌααααΎααα·ααααααααααααααΆαα·αα αααααααααΆααα ααα»α ααΌααααααααα.
ααΎα ααα»α ααΆαααααααααΆααααΆ OFF αααααΆααααΈααΆαααααΆα αα ααααααααα»ααααα·ααΆααααα¬αα?
αα ααΈααΆααααααα αΆαααα·ααααααααααΆααααααααα½αα―ααααααα αααααΆααααΆαααααΆα αα ααααααΎααααΈααααΆα ααΌααααααααααΆααααΆα§ααααααααααΆααααααααααααααααααΆααααΆαααααΆα αα αααα ααΆαααα‘αΎαααααΉαααααΌα α’αΆα α αΆααααααΆααα ααααααααααααααΌα αα·αααααΎααααΆααααααααΆαααΈαα·αα·ααΈαααααααααΆαα αα·αααΆαα αΆαααααα»ααααα·ααΆαααααααΆαααααΆαα.
ααΎα§ααααααα½αααΆαααααα’αααα»ααααααΆαααα»αααΆααααααααααΆαααααααΆααααααα»αααΆα?
αα αααα»αααααΆαααααααΆααααααα»αααΆαααΆα αααΎα αα»αααΆααααααΆα αα αααα (switch-disconnector) ααΊααΆαααααΎαααΆααααααα αααααΆαααΆα’αΆα αααααααΌαααΆααα·αααΎαααααα αα·αααΆαααααΆα αα ααααα ααΆαααααΎαααΎαα α»ααααααααΊα’αΆαααααααΎααααα·αα αααα ααα»α ααααααααααΆαααααΎααααΆαα αααα’ααααΆαααΆα αααααΌαααΆαα αΆαααα αα·αααααααΆααααα»ααααα»αα.
αααααα
ααΆααα»αααααΆαα·ααααααααΆααααααΆααΆαααααα ααααα»αααααααα.
- Disconnector (α§αααααααααΆα αα αααα): ααΆαααααΆα αα ααααααΆα’αΆαα·ααΆα ααΆααααααΆααααΎα‘αΎααα αααααααΆαααααα»αα.
- Isolator (α§αααααααααΆα ααα»ααααα·ααΆα): ααΆααΆαααααΌααααΌααΆααααααΆααα§αααααααααΆα αα αααα ααααααααααΆαααααααΆα’αΆαααααααΎααΆααα ααΆα.
- αα»αααΆααααααΆα αα αααα (Switch-disconnector)α ααΆααα·αααΎα αα·αααΆαααααΆα αα ααααααααααααααααααααααΆααααααα.
- αα»αααΆααααααΆα αααααα»α (Load break switch)α αα ααΆα‘αΎααααααΆααααααΆαα αα·αααααΆα αα αααααααα»αααααααΆα.
- αα»αααΆααααααΆα αα αααα (Disconnect switch)α ααΆαααααΌαα αααααΆααα§αααααααααΆα αα αααα ααΆαα·ααααααα»αααΆαααααΎααααΆαααα α’αΆαααα·αααΆαααΎα α¬ααΆαααααΎααααΆααααΌαα α.
α αααΆαααααααΆααα»ααααα·ααΆααααα»αααΊααΆααααα αα»αααααΎαααΎααααααα’ααααΎααααααααα½ααα»αα ααΌαααααΎαααΎααααααα’ααααΎαα»αααΆα, ααααα·αααΆααα, ααααααααααΆαααααΎααααΆαα, ααΆααααααααααααΆααα ααααααααΆαα/α ααααααααΆαα (AC/DC), αααααΌαααΆαααααΆαααααΆα αα αααα αα·αααΆααααααααααα½αα ααααααααΆααααααΈ (Short-circuit coordination)α.
Sources Used
- αα·αααααΆαααΌαα ααα§αααααααααΆα αα αααα αα·αααΆααα»αααααΆαααΆααα»αααΆααααααΆα αα αααα (Switch-disconnector)α
- ααΆαα αΆααααααΆααα§αααααααααΌα (Switchgear): α§αααααααΆααα αααα (Circuit breakers), αα»αααΆααααΆααααααα»α (Load-break switches) αα·αα§αααααααααΆα αα αααα (Isolators)
- ααααααααααΆαααααΎααααΆαα (Utilization categories) αα·αααα·αααααααααααΆα IEC 60947
- αα·αααααΆαααΌαα ααα§αααααααααΌαααααααα»αααααα (High-voltage switchgear): α§αααααααααΆα αα αααα (Disconnectors) αα·ααα»αααΆααα α»αααΈ (Earthing switches)