VIOX FCT18-Xd Asymmetrical On-Delay and Off-Delay Timer Relay ααΆαα½αααΉααααααΆαααααΆ
VIOX FCT18-Xd Asymmetrical Timer Relay αααααααΆααααΆααααααΆααα ON-delay αα·α OFF-delay (0.1s-100 αααα) αααααααα‘αΎαααααααααΆαααααΆα ααα α»α <0.5%, NPN/PNP, 1/2 SPDT, AC/DC 12-240V α ααα’αααα»ααααααΆααααααααααααααα·ααααα§ααααΆα αααααααααααΌαααΆααααααααΆα αααΆααααΆαα ααααΆααααααααααααΆαααααααα·ααΈααΌα ααΆ conveyor α¬ααΆαααααααααααααΌαααα
ααααΎαααααΌαααΆαααααα’ααα ααΎαααΉαααααααααααααΆααα’ααααααα»ααααααα 12 ααααα
- ααΌααααααα +8618066396588
- Whatsappα+α¨α¦α‘α¨α α¦α¦α£α©α¦α₯α¨α¨
- Email:sales@viox.com
αα·αααααΆαααΌαα ααααα·ααα
VIOX FCT18-Xd ααΊααΆααΆααααααΌαααααααα·ααΈααααααααααααΆ asymmetrical ααααα·αα§ααααΆα αααααααα’αΆα ααααΎααΆαα αααΎααααααααΌαααΆααα ααΆα‘αΎαααΎααααΈαααααααΌαααΆαααααααααααααααααΆ ON-delay αα·α OFF-delay αααΆαααΆααααΆαααα αααα»ααααα αααααα’αΆα ααααααααΌαααα DIN ααααα½αααΆαα α§αααααααααααααααααΆααααααΎαααααααααααΌαααΆααααααααα·αααααΆαα½αααΉααα½ααααααααΆαααα’αΆα αααααααΌαααΆαααΈ 0.1 αα·ααΆααΈαα 100 αααα αααααααΎα±ααααΆαααααα·αααααααΆααααΆααα»αααααΆααΆα αααΎαααααααααααααααα·ααααα§ααααΆα αααα ααΆααααααααααααααΎαααΆα αα·ααααααα·ααΈααΆαααΆαα§αααααα
αα ααΆα‘αΎαααΆαα½αααΉααα»αααΆαααααααααααααΆααΈα (T1 αα·α T2) FCT18-Xd α’αα»ααααΆαα±ααα’αααα’αα»ααααααΆααααΆαααΎαα‘αΎαααα (ON-delay) αα·αααΆαααααΆααα α»αααα (OFF-delay) ααααΆαααα αααα»αα§ααααααααα½αα ααΆαααααααααααααααααΆα αααΆααααΆααααααα’αααααΆαααα αα½αααααααΆαα½αααΉαααΆααα ααΆααααΉαααΆα αα·ααααααΎαααααΆαααααααααααααΆααααααα’αΆα ααααΎααααΆααααΆα ααααΎα±ααααΆααααΆαααΆαααααααααΆαααααα’αααααΆαααααααααααααααΆαααΆαααααα·ααααα·ααΆαααααΌαααΆααααααααΆααααΉαααααΌαα
αααααααα·ααα αα·αα’αααααααααααααααΆααα
- αα»αααΆαααααααααααααΆααΈαα αα½ααααα αΌααα»αααΆααααααααααααααΆααα ON-delay αα·α OFF αα αααα»αα§αααααααααα½ααααα½α ααΆααααααααααααΌαααΆαααα αααααα αα·αααααΎα±ααααΆαααα‘αΎαααΆααααα½αα
- αα½ααααααααΆααΌααααΌααΆαα ααΆααααααααα·αααα αααααααααααα½αα±ααααααααααΆααααΈ 0.1 αα·ααΆααΈαα 100 αααα αααααααααααααααααΎαααααααααααααα·ααΈααααααααααααΆα§ααααΆα ααααα αΆααααΈααΆααα·ααααααΏααα αΌααααααΆααααα½ααα·αα·αααααααΎαααΆαααααααα
- αααααααΆα αααΆααααΆαααααααα αααααααΌαααΆαααααΉαααααΌααααααααααΆαα·αααααΆαα½αααΉαααα α»ααααααααΆαα·α ααΆα 0.5% αα·ααααααΆααααααααΆ 0.1% ααΆααΆααΌαααααα·ααααα·ααΆααααα’αΆα αα»αα α·αααααΆα αα·αααΆααααΆααα
- ααΆαααααααααααααΆααααααα ααΆααααααΆαααααααααααααΆαααααααΌααΆαααΈ 12 αα 240 VAC/DC αααααααΆαααααααΌαααΆααααααΆαααααΌαααααααααααααΆαααααΆαααααααααΆαααααααααα
- ααααααΆαααααα·α αα αααα’αΆα αααααααΌαααΆαα αααααααα·αααααΆαααααααααΆααΆαααααΈ 10% ααα 100% αααα’αα»ααααΆαα±ααααΆαααΆααααααααααα αααΆααααΆααααΎααααΆαααααααααααααΆαααααα ON/OFF α
- ααΆαα ααα’α»ααααα αΆαααααΆαααΆααααααΎαααΎαα αα½ααααα αΌα LED ααααααααααααΆααααΆαα ααα’α»ααααα αΆαααΆααααααααααα αα·α LED ααααααα ααααααΆααααααΆαααΆααααααΌααααα αααααααΌαααα·αααααα’ααααα·ααααα·ααΆαα αααΆααααΆααα
- ααΆαααααααα ααΆααααααααααΆααααα½αα ααΆααααα αααααΆααααααΆαα½αααΉαααΆαααααααααααα·α αΆααααΆααααααΆααααΆαααααααααααααΆ αα·ααααΆααΆααα ααΆααααααααααααααΆααααΆαααΆαααααααααΎαααΆαα
- αααααΎααααα½ααα·αα·αααα αααΎαα α’αΆα ααααΎααΆαααΆαα½αααΉαααΆαααααααΆαααααααΆαααα½ααα·αα·ααα NPN α¬ PNP αααααΆααααΆααα½ααααα αΌααααααααΆααααααααΆαα½ααααααααααααα½ααα·αα·αααααααααα
- αααααααΆααααααΆααααΆαααααααααααααααΆααα ααααΆααααααΆαα½αααΆαααΆαααΆααααααΆααααΉααααααααααΆαα’αααα·αααΈ ααΆααΆααΌαααααα·ααααα·ααΆααααα’αΆα αα»αα α·αααααΆααα αααα»αααα·ααΆααΆαα§ααααΆα ααααααα’αΆαααααα
- ααΆαααα‘αΎαααααΌαααα DINα ααΆαααααΆααααααΌαααα DIN αααααααΆαααΆα EN/IEC 60715 αααααααΎα’ααααΆαααα‘αΎααααααααΆαααΆαααΆαααα αα·αααΆααα½ααααα αΌαααααααααα
- αα½αααΈαα»ααα ααΆαααααΌααΆαα ααααΎαααΆαααΈ -20Β°C ααα +60Β°C (-40Β°F ααα +85Β°F) αααααααααααΆααααααααααααα·ααααΆαα αααα»αα
ααΆααααααΉαα’αααΈαα»αααΆαααααααααααααΆ FCT18-Xd
FCT18-Xd αααααααΌααα»αααΆαααααααααααααΆααααααΎαααααα½ααααα αΌαααααΆααΆααααααα·ααααα·ααΆα ON-delay (rising edge) αα·α OFF-delay (falling edge)α αα αααααααααααΆαααααΆ (S) ααααΌαααΆαα’αα»ααααα

- αα ααΎαααααΎαα‘αΎα (αα αααααα S ααααΌαααΈ OFF αα ON) αα·ααααααααααΌααααα (R) αα αααα·ααααααΆαααααααα T1 (ON-delay) α
- αααααΆααααΈ T1 ααααααα»ααα αα·ααααααααααΌαα (R) ααΎαα
- αα ααΎαααααααΆααα α»α (αα αααααα S ααααΌαααΈ ON αα OFF) αα·ααααααααααΌααααα (R) αα ααααΎααααααΆαααααααα T2 (αα·αααΆααααααΆαααα) α
- αααααΆααααΈ T2 ααααααα»ααα αα·ααααααααααΌαα (R) αα·αα
αααααααΆαααααααααααααΆααΈααααα’αα»ααααΆαα±αα FCT18-Xd αααααααΆαααααΆαααααααααΆαααααα»αααααΆαααΆαα½αα§ααααααααα½α ααααα»αααααΆαααααααΌαααΆααααααΆαααααααα·ααΈαααααααααα αααΎααα αααα»ααααααα·ααΈααΆα αααΎαα
αααααΎαααααααααααααΆ
FCT18-Xd αααααααΌαααΆαααααααααααααΆαα·ααααα½α ααΎααααΈααααααααααΌαααΆααααααααΆα§ααααΆα ααααααααΎαααααΆααα’ααα

| 0.1-1 αα· | 1-10s | 0.1-1 αα | 1-10 αα | 0.1-1 ααααα |
| 1-10 ααααα | 0.1-1 ααααα | 1-10 ααααα | 3-30 ααααα | 10-100 ααααα |
α ααααααααααΈαα½ααα’αΆα ααααΎαααΎαααΆααααΆαααΆααααα½αααΆαααααα»αααΆαααααΌααΆααΈααα ααΎαααααααΆααα»α αααα’αα»ααααΆαα±ααααΆαααΆαααααΆααααααΌαααΆαααααααα ααΆαααααααααα ααααααα·αααΆα ααααααααα α¬αααα½αα
αααααααΆαααααααααΆααΆααα
αααααααα·αααααααααα FCT18-Xd ααΊααΆαααααααααΆααΆααααααα’αΆα αααααααΌαααΆαααααααΆ αααα’αα»ααααΆαα±ααα’αααααααααααααααΆααΆααααααααααΆαααΆαααΆααααΆαααααΆαααααΆααααΆααααααααααΆααααααα·ααααα·ααΆαα αααΆααΆαααα’αΆα ααααΌαααΆααααααααΈ 10% ααα 100% αα αααα»αααΆααααααΎαααΌα ααΆααααααα

| 10% | 15% | 20% | 25% | 30% | 35% | 40% | 45% | 50% | 55% |
| 60% | 65% | 70% | 75% | 80% | 85% | 90% | 95% | 100% |
ααΆααααααααααα’αα»ααααΆαα±ααααΆαααΆαααααΌαααΆαααααα αααΆααααΆαααααααααααααααΆ αααααααΎα±αα FCT18-Xd αααααααααααΆαααααααα·ααΈααΆα αααΎααααααΆαααΆαααααααΆαααααα·α αα αα·α/ααΎαααΆααααΆααα
αααΆααααααααααΌ αα·αααΆαααααΆαα’αααΈααΆαααααΎαααΎα
αααααΈ FCT18-Xd ααΆααα αααα»αααΆαααααααααααα ααΎααααΈαααααααΆααααααΌαααΆααααααα·ααΈααααααααααΆα αααβαααΌαααβααΆαβαα ααΆααααααααβααΌα βααΆαβαααααα
FCT18-Xd 1 WN
| αα»αααααα | ααΌα | ααΆααα·αααααΆ |
|---|---|---|
| 1. αα»αααΆα | Xd | αα·α-ααΎαααΆααααααΆαααααααΌα |
| 2. αααααααααα·ααααα | 1 | 1 CO ααααΆαααααα |
| 2 | ααααΆαααααα CO 2 | |
| 3. ααα»ααααααααααα | αα½α | AC230V |
| α | DC24V | |
| α | AC/DC12-240V | |
| 4. αααααΆαααα½ααα·αα·ααα | α | α’α·αααΈα’α·α |
| αα | PNP |
ααΆαααααααα ααΆαααααααααααα
FCT18-Xd αααααααΌααααααΎααααααααααααααααααααΆααααΆαα NPN αα·α PNP αααααααααααΆαααα½ααα·αα·αααα

ααΆαααααααα ααΆαααααααα NPNα
- ααααΆααααΆαααααααααααααΆααααα ααααΆααΈα A1 (DC + / AC L) αα·α A2 (DC- / AC N)
- ααααΆααααΆααααα αΌααααααΆαααααΆ (S)
- ααααΆααΈααα·ααααα: 11, 12, 14 αααααΆααααααααααΆαααααα CO αααα½α; 11, 12, 14, 21, 22, 24 αααααΆααααααααααΆαααααα CO ααΈα
ααΆαααααααα ααΆαααααααα PNPα
- ααααΆααααΆαααααααααααααΆααααα ααααΆααΈα A1 (DC + / AC L) αα·α A2 (DC- / AC N)
- ααααΆααααΆααααα αΌααααααΆαααααΆ (S)
- ααααΆααΈααα·ααααα: 11, 12, 14 αααααΆααααααααααΆαααααα CO αααα½α; 11, 12, 14, 21, 22, 24 αααααΆααααααααααΆαααααα CO ααΈα
αααααααα αα ααααα
| αααααααα αα ααααα FCT18-Xd | ||
|---|---|---|
| ααααΆααΈααααα αΌα | A1-A2 | |
| αα½αααα»α | AC 230V / DC24V / AC / DC 12-240V | |
| ααΆαααααΎααααΆααααΆααα | AC 3.5VA / DC 2.0W | |
| ααΆααααααΉαααα»α | -15%~+10% | |
| ααΆαα ααα’α»ααααα αΆαα’αααΈααΆααααααααααα | LED ααααααα | |
| ααΌα ααΆαααααααΌαα | LED αααα α | |
| α αααααααα | 0.1s-100 ααααα | |
| ααΆαααααααααααααΆ | αααΌαα»α | |
| αααααΆααααααααΆ | 0.1% | |
| ααΆαααααΉαααααΌαα‘αΎααα·α | 0.5% | |
| αααα»αααΈαα»ααα ααΆα | 0.05%/Β°C, αα =20Β°C (0.05%/Β°F, =-68Β°F) | |
| αα·ααααα | FCT18-Xd1 | FCT18-Xd2 |
| ααααΆαααααααα·ααααα | 1 * SPDT | 2*SPDT |
| ααΆαααααααα αα α»αααααα | 1*16A | 2*16A |
| αααααααα αα αααααααΌαα | ||
| ααΈαα·αααααΆαα·α | 1*107 | |
| ααΈαα·αα’αααα·αααΈ | 1*105 | |
| ααΈαα»ααα ααΆαααααααα»ααα·α | -20 ... +60 Β°C / -40 ... +85 Β° F | |
| ααΆααααα | ααααΌαααα DIN EN/IEC 60715 | |
| ααΆαααΆαααααα IP | IP20 | |
| αααααααα | 7 αα (0.28 α’ααΈα) | |
| αααααααααααΆαααα‘αΎα | β€ 2200 αα | |
| ααααα·ααααα»α | 2 | |
| ααα αααααα’αα·ααααΆ | AWG13-20 0.4NΒ·m | |
| αα·ααΆααα | 90mm * 18mm * 64mm | |
| αααααα | αααα αα 90 ααααΆαα | |
| αααααααΆα | GB/T 14048.5, IEC60947-5-1, EN68112-1 | |
αααααα·ααΈ
ααΆααααααΌαααααααα·ααΈααααααααα FCT18-Xd ααΊααα’αααααΆαααααααα·ααΈα§ααααΆα αααα αα·αααΆαα·αααααααααΆα αααΎα ααααααααΌαα±ααααΆαααΆαααααααααααααααααΆα αααΆααααΆααα
- ααααααααααααα·ααααα§ααααΆα ααααα ααααααααααΉααααααΌα α§αααααααααααααααααααΆαα αααΆαααΈαααα ααα αα
- ααΆααααααααααααααΎαααΆαα ααααα·ααααα·ααΆαααΆαααααΆααααααα ααααΎαααΆαααΆα α ααααααΆα αα·αααΆα
- αααααααα HVACα ααΆαααααααααααααα αΆα ααΆααα·ααααααααα ααΆααααααααααααΈαα»ααα ααΆα
- ααΆαααααααααααααααα ααααααααααΆααΆααΆααααα ααΆαααααΆααΆαααΉα ααΆαα αΆααααααΆαααΈααΈ
- ααΆαααΆαααΆααααΆαααΈαα αααααααααααΆαα ααΆαα αΆααααααΎααααααΆαααααααααΆααααΈααΆαααααΆαααΆααα
- ααΆααααα½ααα·αα·ααααααααΊα ααααΎαααααααΊααΆαααααΆααααααα αααααΊαααααΎα ααΆααααα αΆαααΆαααααααΊ
- ααΆαααααααααααααΌαααα ααΆαα αΆααααααΎαααααΆα-ααΈαααα αααααααΆαααααΎαααααΏα/αααααααααΏα
- ααΆααααααααααααΆαααα ααΆααααα»αααααα, ααΆαααααααααααααααΌαααΆαααααααααα»α
- ααααααααααααα·αααααααααα αααααααααααααααααααΆαα αΌαααααΎ ααααΎααα»ααααα·ααΆα
- ααααααααααα·ααααα ααΆααα·ααΆαααααααααααΆααΆααΆααααα ααΆαα ααα αΆαα αααΈ ααΆααααααααααα’αΆααΆαααΆαα»
ααΆαααααΆαα’αααΈααΆαααα‘αΎα
αααααΆααααααΎαααΆαααα’αααα»α αα·αα’αΆαα»ααΆαααΌαααααΆααααααΌαααααααα·ααΈαααααααα FCT18-Xd ααΎαααΌαααααΆαα±ααααααΎααΆαααΆαααααΆαααα‘αΎαααΆαααααα
- ααααΆααα§ααααααα ααΎααααΌαααα DIN αααααααΆα 35mm αααα»αααα·ααΆααΆααααα½α αα·αααα’αΆαα
- ααΆααΆα±ααααΆααααααα ααα αΌααααααααααΆαααα αα»ααα·αα§αααααααΎααααΈααΆαααΆαααΆαα‘αΎααααα ααααΆααα
- αααααΆααα·ααΆααΆαααααα·ααααα·ααΆααααα»ααα½αααΈαα»ααα ααΆααααααΆααααααΆαα (-20Β°C ααα +60Β°C)α
- ααααΎααα αααααααααααααα (AWG13-20) αααααΆααααααΆααΈα αα·ααααααΆαααααααααααααΆαααααΆα 7mmα
- αααααΆαααΆαααα‘αΎααα αα·ααααααααααΆαααααααααααα’αα‘α·α ααααΌαααΆααααα·α ααααΆααα
- ααααΌαααααΆααααΆααα»ααααα αΌαααααΆαααααα»ααα½αα’ααααααααααααΆααααααΆααα
- αα αααααα‘αΎαα§ααααααααααΌααα αααΎα ααΌααααααΆαααααΆαα±ααααΆααααααααααΆαααααΆαα§ααααα ααΎααααΈα’αα»ααααΆαα±ααααΆαααΆααααα αααααα α
- αααααααααΆααααΆααααααΆααααΆααα’ααααΆααα»ααααα·ααΆα αα·αααΉααααααΉααααΆαααααΉαααααΌααα ααΉααααααΆααααααα·ααα»ααααααΆααααααΆαα (0.4NΒ·m)α
- ααΆαααααΆααααααααααΎαααΆααααααΆααααααΆαααααααα’ααααααααΆαααΆααααα½αααα‘α»ααααααααΆαα
- αα·α αΆαααΆααααΎα§αααααααΆαααΆαααΆαααΎαα‘αΎα αα αααααααΎαααΆααααα»αααα·ααΆααΆααααααΆααααααααααΆαα’αααα·αααΈ α¬ααΆααααααααααα½αα
ααααααΆαα’αααΈαα·ααΆααα
FCT18-Xd ααΆαβααααααβαα·αααβααβααΆαβαα ααΆβααααα½αβαααβααααΌαβααΆαβααααΎβα±ααβαααααΎαβα‘αΎαβαααααΆααβααΆαβααααΎβααααΆααβααααααααβααααα·αααααΆαβααβααα αβαααααβα

- ααααααα α©α αα
- αααΉαα α‘α¨ αα
- ααααα α α¦α€ αα
- ααααα: αααα αα 90 ααααΆαα
ααΆαα’αα»αααααΆα αα·αααΆααααααΆαα
ααΆααααααΌααααααααααααααΆ FCT18-Xd ααααΌαααΆαααα·αα‘αΎαααΎααααΈα’αα»αααααΆααααααααΆαα’ααααααΆαα·ααΆααααααα
- GB/T 14048.5
- IEC60947-5-1
- EN68112-1
αα·ααααΆαααααααααΆαααααααΆααΆααΆα§ααααααααααααΆααααααΌαααΆαααααΉααααΉααααααΆαααα»ααααα·ααΆα ααΆαααΏααΆαα αα·αααΆαααααααΆααα’αα‘α·α ααααΌαααΆααααα·α αα αααα»αααα·ααΆααΆαα§ααααΆα ααααα
α ααα»α’αααΈααααΌαααααΎαααΎα VIOX FCT18-Xd?
FCT18-Xd ααααΆαα±ααα ααα»α ααααΌαααααααΆααα·αααααααααΆα αααΎαααααΆααααα»αααΆαααααααααααααααααΆα§ααααΆα ααααα αααβααΆβααΌαα ααα»βαααβααΆαβαααααΌααβαααααα·ααΈβαααααβααααβαα·αβαααΈααααααΈβαααβααα ααααβααΈβααΆαβααααα½αβααααααα
- ααΆαα αααα»ααα·αααα ααΆαα½αααΉααα½ααααααααΆααααααΌααΆαααααααΆ αα·αααΆαααααααααΆααΆααααααα’αΆα αααααααΌαααΆα FCT18-Xd α’αΆα αααα½αα§αααααααααααααααααΆα―ααααααΆα αααΎααα αααα»αααΆαααΎαααααααααα’αααα
- ααΆαααΏααΆαααααααα αα ααΆα‘αΎαααΆαα½αααΉααααΆαααΆαα»ααααΉαααΆα αα·ααα»αααΆαααΆαααΆα FCT18-Xd αααααααΌαααααΎαααΆαααΆααααΆααααΌααααΈαααα αααα»αααα·ααΆααΆαα§ααααΆα ααααααα’αΆααααααααααα
- ααΆαααΆααααααααΆαααα‘αΎαα αααααααααΆααααΆαααααααααΎα ααΆαααα‘αΎααααααα αα·αααΆααααααααααααααα·α αΆααααΆα ααΆααααααααααααααΆααααΎαααΆα αα·αααΆααααααααααααΆαα»αααααααΆααααα α»αα
- ααααα·αααααΆαα’αααΆαα ααΆααα ααΆααααα½ααααΉα 18mm αααααΈαααΆαααααΎααααΆααααα ααααααααααα·ααααααΆααααααα»αααΆα α¬ααααΎαααΆαα
- ααΆαααααααΆααΆαααα ααΆαα½αααΉααααααΎααααααΆαααα½ααα·αα·ααα NPN αα·α PNP αα·ααα½αααα»αααααααααααααααΌααΆα FCT18-Xd αα½ααααα αΌααααΆααααΌαααΆαα½ααααααααααααααααααααααΎαααααΆααα’ααα
- ααααα·αααααΆαα αααΆαα ααααα½ααααα αΌαααααΆααΌααα»αααΆαααααααααααααΆααΆα αααΎααα αααα»αα§ααααααααα½αααΆαα½αααΉαααΆαααααα·ααα FCT18-Xd αααααααΌααααααααα’ααα αΆααα αα·αααΆαααααααααΆαα αααΆαααΎαααααα·αααα·ααα»αα
ααα ααααΈααααα·
VIOX FCT18-Xd asymmetrical on-delay and off-delay timer relay with control signal ααααΆαα±αααααααααααΆααααααα»αααααααΆα ααα»ααααααΆααααα½αααααΎαααααΆαααααααα·ααΈαααααΆαααΆαααΆαααααααααααααααααΆα αααΆααααΆααα ααΆαα½αααΉααα½αααααααΌααΆααααααααΎααααααααΆ αααααααΆααα»αααΆαααΈα αα·αααΆααα ααΆααααΉαααΆα α§ααααααααα’αΆα ααααΎααααΆααααΆαααααααααααΌαααααΎαααΆααααα·ααααα ααΌααΆαααα·ααΆαααααααΌααΆααααααααα·ααΈα§ααααΆα αααα αα·αααΆαα·αααααααα
αα·αααΆα’ααααααα»ααα ααΆααααααααααααΈ α¬ααααΎα±αααααααΎαα‘αΎαααΌαα§ααααααααααΆαααααΆααααααα FCT18-Xd αααααααΌαααΆααααααα ααΆαααΏααΆαα αα·αααΆαααΆααααα½αααααΆαααααΎααααΆαααααααααααααααααα·ααααααααΎαααΆαααΆαα ααΆαααααααα»ααααα½ααα αα αααααααααααΎαααααααα ααΎααααΈααααααααααΈααααααα FCT18-Xd α’αΆα αααααΎααααααα·ααΈααααααααααααααααΆααααα’αααα