ααΆααα»αααααΆαααααΊααΆααααα αααα Line ααΆαααΆαααααΈααααααα ααΆααα§ααααα αααα Load ααΆαααΆαααααΈα§αααααααααα ααΆααααααα»ααα αααααααΆαααααα α αΎααααα Neutral αααααααααααΈαααααΆαα αααααααα‘αααα ααααααα·α.
ααα»ααααααΆαα ααα»α αααα’α·ααα½ααααααααα±ααααΆαααΆαααΆααα ααα‘αα αααΎααααα»ααααα»αααΆααααααΆααααααααααΎαα Line αα·α Load ααΊααΆααΆααααααααΆααααααΉαα§ααααα. αααααα½αα’αΆα ααΆαααα Load αα ααΎα§ααααααα½α α αΎαααααΆαααΆαααα Line αααααΆααα§ααααααααααΆαααα αααααααΆααααααα α αααα Neutral ααΊαα»αααααΆα ααΆααΊααΆααααα ααααααααααΈ αα·ααααααΆααααΆααααααΆαα βααααααααααβ α¬ βαααααααααα»αβ αααααα.
ααααααααααΆαααα»ααααα·ααΆαα α’ααααααααααΊαααααΆαααααααααα’αααααααααα’αααα·αααΈ αα·αααα·ααααααΆαααααΎαααΎαααααΏαααα·ααααΆαα ααΆααααααα’ααααααααΆααααααααααΆαα αααα α¬ααΆαααααΆααααααΌαααΆααααααΆααααααααααΎα αα½αααααααΎα‘αΎααααα’αααααααΆααααααΆααααααααΆα αααααααΎα§ααααααααααααααΉαααααΌα αα·αα’αα»αααααΆααααααΌαααΆαααααααΆααααα»ααααα»αα ααααααα½ααα»ααα·ααααααΆααΆαααααΎααααααα»ααααα·ααΆααααα’αΆα αα»αα α·αααααΆααααααα.
ααΆααααααααααα ααα Line, Load, Neutral αα·α Ground

| αααααααααα | α’ααααααααααααΆ | ααΎααΆααααααΆααΆαα ααααααααααΆαααααα¬αα? | αααααΌαα αααααααΎαααα»αααααααααααΆα αααΎααα αα ααααα’αΆαααα·α | αα»αααΆαα αααα | ααΆααααα»αααααααααααααΆααα |
|---|---|---|---|---|---|
| αααααααααΆαα | ααααααααααααααα ααααα αΌαααααααααΌααα ααΆααα§ααααα | ααΆα αα ααααααααααααΈααΆαα ααααα’αααα·αααΈ | ααααααα αααα α α¬αααααααααααααααααααααα·αααΆαααΆαα α»αααΈ | αααααΌαααΆαααααΈα§αααααααΆααααααΆα α (Breaker) αααααααΆααα α¬α§ααααααα αααααααΆαααΎααααααααΈ | ααΆααααααααααΆααααΌααααΈαααα»αααααα»αααΆαα α¬α§αααααααααΎαααΆαααααα |
| αααα»ααααα | ααααα ααααα ααααΈα§ααααααα ααΆααααααα»ααα αααααααΆαααααα | ααΆααααα ααααααα§ααααααααααΌαααΆαααααα»ααααα | ααΆααΉαααΆααααΆαααααααα αααα α α¬αααααααα αααααααα αααααααα | αααααΌαααΆααααα ααΆααα’αααΌαααααΎα ααααααα αααΌααα α§αααααααααΎααααΆαα α¬α§ααααααααααΆαα | ααααα·αααααΌαααΆααααααααΆααααΆαααα αα»αααΆαα’αΆααααααα ααΎαααααααααααΆααααΆαα |
| ααααα’ααααΆααααΉα | ααααααααααΈαααααΆαααΈαααααΆαααααααΌαα αααααααα‘αααα ααααααα·α | α’αΆα αααα»αα ααααααΆααααα»αα’αα‘α»ααααααααα·ααααα·ααΆαααααααΆ | αααα α¬ααααααααα αα αααα»αααααααααα’αααα·αααΈα’αΆαααα·αααΆα αααΎα | αααααααααΌααααα‘ααααααααααΈα’αααα·αααΈ | αα·ααααααΆ βααααααΆααα»ααααα·ααΆαβ αα; ααααααΊα (Neutral) αααααΆα α α¬ααααΎαα½αααααΆα’αΆα αααααααααααααΆαα |
| ααααααΈ | α§αααααα ααααααΈ | ααΆααααααΆαα·αααΆαα ααααα’αααα·αααΈααααααΆαααα | ααααααα αααααααααΆαααΏα α¬ααααααααΆααααα | αααααααααΌααααααΆααα ααααααα ααααΆα (Fault-current) ααΎααααΈαα»ααααα·ααΆα | αα·ααα½αααααΎααΆααααααΊα (Neutral conductor) α‘αΎα |
ααααα·αααΎα’αααα αΆαααΆαααα αααΆαααα½α ααΌαα αΆαα ααα»α αααα αααα Line αα·α Load αα·αααααΆα’αααΈαα·ααα ααααααΆααα§ααααααα½α α ααααα―αααα Neutral αα·α Ground αα·αααααΆα’αααΈαα»αααΆαααααα αα αΆααα αααα»αααααααααα’αααα·αααΈα.
ααΎα’αααΈαα ααΆαααα Line?
αα½α αααααααααΆαα ααΊααΆα αα αΆααααααααααααααααΆααααααα§αααααααΈααααααααααααααααααΈα αααααα’αΆα ααΆα§αααααααΆααααααααΈ (Circuit Breaker), α ααα»ααααΈα (Fuse), ααΆααααΌα’αααα·αααΈ (Distribution board), ααΆααααΌαα (Main panel), ααααααααααΌ (Transformer), αααααααΆααα (Power supply) α¬αα»αααΆαααα αααααααΆαααΎ (Upstream switch)α.
αα αααα»ααα»αααΆαααααααΆαα αααα Line ααΆααααααΆααΊααΆα αα αΆααααααΆαααααΎαααΆαα·α αα ααααααααααααααα α±αααα»αααΆααα αα αααα»αααααΈααααΎααααααΆααα»αααΆαααΆαααΆαααΆαααα ααααΆα (GFCI) ααααΆααΈα Line ααΊααΆααααααααα½αααΆαααααααααααααΆαααα αΌαα αα αααα»αααΆααααΌαα»αααΆααααΆαααΆα (Circuit breaker panel) ααααα Line ααΊααΆαααααααααααααααααααααααΌαααααΎααα α±αααα»αααΆααααΆαααΆαα.
αααααΆααααα·αααααΆαααΆαααααααΈαααα VIOX ααΌα ααΆ MCBs αα·α RCBOs, ααΆααααααΆααααααα Line αα·αααααα Load ααΊααΆαααΆααααααΆαα αααααΆαα§αααααααααΌααααααααΆααααααααΆαααΆαααααααα ααΎααααΆααΈα αα·αααΆαααΆαααααΆαααααααα·αααα α§ααααααα½αα ααα½αααΆαααΆααααΎαα αααααα·ααα Line/Load α ααααα§ααααααααααααα’αΆα αα·αααΌαααΆαααΆααααΎαα αααααα·ααα αααα’αΆαααααααΎααΆααα ααΆ αα·ααααααααΆαααααααΆα.
ααΎα’αααΈαα ααΆαααα Load?
αα½α αααα»ααααα ααΊααΆα αα αΆααααα ααααΈα§ααααα αα·ααααααΌαααΆααααα ααΆαα Load αααααΆααααααΆαα α¬ααααααΈαα αααααααΆαααααα (Downstream circuit)α Load α’αΆα ααΆα’αααΌαααααΎα, ααααΈααααΎα, ααααΏαααααΎααααΆαα, αααΌααα, ααααααα‘α (Relay coil), ααααααΈαααααΆ α¬α§αααααααΆαααΆαααααααααα.
α§ααΆα ααα αα αααα»ααα»αααΆααααααΎαααΌαααααΆααα½αα
αααααααΆααα / αααααααΊ (Breaker) -> ααααΆααΈα LINE αααα»αααΆαα
αα ααααα»αααΆαααααα·ααααα»αααααΆαααΆααα·α (OFF) ααααα LINE α’αΆα αα ααααΆαα ααααα’αααα·αααΈ αααααααα LOAD αα·ααα½αααΆαα ααααα’αααα·αααΈααααααΆαααα»αααΆαααααααα αα ααααα»αααΆαααααα·ααααα»αααααΆαααΆαααΎα (ON) αα»αααΆααααΉααααααΆαα LINE αα ααΆαα LOAD α αΎαααΆαααααΉααα αααα’αααΌαααααΎαα.
αααααΆααΌαα ααα»ααα βααααααα LOADβ ααΊααΆααΆαααααααααααααααΆαα αΆαα·αααα αααα LOAD αα·αααΆαααααααααααΆααααα½ααααααα ααΆα αααΎαααααΆααααααΌα ααααΆαα ααΉααααααααααΆαα αααα (Hot conductors) αααααααα α αΎααα»αααΆαααααααΆααααΌααααααααΆαααααααΈααΆααααααααΈ αα·αααΆαααααΎααααα αα·ααααααα’ααααΎααααααα½ααα»ααααααα.
ααΎααααα’ααααΆααααΉα (Neutral Wire) ααΆα’αααΈ?
αα½α ααααα’ααααΆααααΉα ααΊααΆααααααααααΈαααα α»αααΈ ααααααααααααΌααααα‘ααααααααΆαααααΆααα ααααα’αααα·αααΈα αα αααα»αααααααΈ AC ααααΆααααΆααααα½α (Single-phase) ααΆα αααΎα α ααααα αΌαα ααααΈαααα LINE ααααααΆαα LOAD α αΎααααα‘αααααα·αααΆααααααααα’ααααΆααααΉαα.
ααααα’ααααΆααααΉαα αααΎαααααΆααααααΆαα»αααα·αααΉαααΈαα αααα»αααααααααααααααααΆααααααΉαααααΌα ααα»ααααααΆαα·ααααααΆααααααΆ αα·α ααΆααααΆααααααααααΆαααααααα ααααα’ααααΆααααΉαα’αΆα αααα»αα αααα LOAD ααΆαα ααααα·αααΎααΆααααααΆααααααα’ααααΆααααΉαααΆα α ααα»α α¬ααααΌαααΆαααααΎααααΆαααα½αααααΆααααα·αααααΉαααααΌα α§ααααααα αααααααΆααααααα’αΆα ααααΎαααΆααα·αααααααααΈ α αΎαααα»ααααααΆααααααααααΆααα’αΆα ααα α‘αΎααα αααααααααα’αααααααΎααααΆαααα·αααΉαααααΆααααα.
αα αααα»αααααααααααΆαααααααα
- αααα Neutral αααααααααααΈαααα»αα’αα‘α»ααααααααα·ααααα·ααΆαααααααΆα.
- αααα Neutral αα·αααΌα ααααΆαα ααΉααααα Ground ααα.
- αα·ααα½αααααΆαααααα Neutral αα ααΉααααα Ground αααα ααααααα ααΆαααααΈααααΎα αα»αααΆαα α¬α§αααααα’αααα·αααΈα‘αΎαα.
- αααα Neutral αα ααα’αΆα αααααααααααααΆααααΆα ααααα·αααΎααααααΈααΆαα ααααα’αααα·αααΈααααααΆαα ααΆααααααΆαααα»α α¬ααΆαααααα»αααΎαα.
αααααΆααααΆααααααααααα’α·αααααααα’αααΈααααΆααααααααααα»α ααΌαααΎαααΆαααααΆααααα VIOX ααααΈααΈ ααα»ααααααΉαα ααααα’αααα·αααΈ.
ααΎα’αααΈαα ααΆαααα Ground?
αα½α αααα Ground, α¬α§ααααααααα»αα ααααα α»αααΈ ααΊααΆαααααα»ααααα·ααΆαα ααΆαα·αααααΌαααΆααα ααΆα‘αΎααααααΆαααααα»αα ααααα’αααα·αααΈααααααΆαααααα αα½ααΆααΈααααααΆααΊαααααααΌαααααΌααααααΆαααΆααααααααΆαααΆααααααΆααα ααααααα αΌααα»αααααααααΈ ααΎααααΈα±ααα§αααααααΆαααΆαα’αΆα ααααΎαααΆαααΆααααα»αα’αα‘α»ααααααΆαααΆαααααα ααααα.
ααααααΈ (Ground) αα·αααααα’ααααΆααααΉα (Neutral) αα½αααΆαααααΌαααΆαααααΆααααααΆαα α ααα»α ααΆααααΆαααα½ααααα»αααααααααα’αααα·αααΈ ααΌα ααΆα§ααααααααααααΆααααα αααα»αααΆαααα‘αΎαααΆα αααΎαα ααα»ααααααΆαα·αααΆααααααΆααΆα’αΆα ααααΎαααα½αααααΆααΆααα αααααααΆαααααααααααααααααααααα αα αααα»αααααααΈααΆααΆ αα·αααΆααααααΆααααααααααΎαα§ααααα ααΆαααααΎααααααΈαααα½αααααα’ααααΆααααΉαα’αΆα ααααα±ααααΆααααααααααΆααααααΆαααα αα·αααΆααααααααΎααααααΆααα αα αααααα.
Line αααααΉα Loadα αααααααααΆαα ααααΌαα αααααααΌαα αααα»α
ααααΆ Line αααααΉα Load αα·ααααααΆααααααΆ βααααα½ααααααΉαααααα½ααααβ αααααα ααΆααΆααααααΆ ααααααααα αΌααααααΉαααααααααα ααααα§ααααααα½α.
| α§αααααααααΌ | ααααα Line (ααααααααα αΌα) | ααααααααα»αααααα»α (Load Side) |
|---|---|---|
| αα»αααΆααααααΎα | ααααααααΎαα αΌα (Incoming hot feed) | ααααααααΎααααααααααΆαααα»αααΆαααα ααΆααα’αααΌα |
| ααααΈααααΎααααααα GFCI | αααααααααΎαα αΌαααΈααααΆααα ααα αΆα (Panel) | ααααΈααααΎαααααααα·ααα αααααααΆαααααααααααΆαααΆαααα GFCI |
| ααααααΈααααΎα | ααΆαααΆααααααααααα α¬ααααααααααααΆααα (Source side) | ααααα ααααα’αααα·αααΈαααααααΌαααΆαααΆαααΆα αααα ααααΈα§αααααααΆααααααΆα α (Breaker) |
| αα»αααΆααααααΆα αα ααααα’αααα·αααΈ | αααααααΆαααα αΌα | αααααααααΌαααΆαααα αααα ααΆααα§ααααα |
| α’αααααααΆαααααα | α ααα»α αααααΆαααααααααΆααα (Supply terminals) | α ααα»α αααααΆααααααα»α (Load terminals) ααααααααΌαααΆααααα ααΆαααααΌααα α§αααααααααα α¬α§ααααααααααα |
αααααα½αα’αΆα ααααΆααααααΌααααααα α αααα ααΆα α’αΆαααααααΎα§ααααααααα’ααααααα»ααα·αα·αααα αααααααα ααααΈαα»αααΆαααα½αα’αΆα ααΆααααααααα»α (Load wire) αααααΆαααα»αααΆααααα ααα»αααααα αααααΆαα αααα§ααααααααααΆαα ααΆα’αΆα ααααΆαααΆααααααααα (Line feed) αααααΆααα§αααααααααα·αα.
αααααΆααΌαα ααα»αααααααΆααααΆαααααΆαααααΌαααΆααααααΆαα ααα»α αααααΆαα αα·ααα·ααα α±ααααΆαα αααΆααααΆαα αααα½αα±ααααΆαααΉαααα’ααααΎαααααααααααΎααααα½ααα»αα.
ααααα (Line) αα·αααααα»α (Load) αα ααΎαα»αααΆαα

αα αααα»αααααααΈαα»αααΆαααααΌααααα½α (Single-pole switch) ααααααααΎαα αΌα (Line conductor) ααΆαα ααααα’αααα·αααΈα αΌααα αααα»ααα»αααΆαα α αΎαααααααααΎαα αα (Load conductor) αααααΌαα αααααααααααααΆαααα»αααΆαααα ααΆααα’αααΌαααααΎα α¬α§αααααα’αααα·αααΈα.
ααααααααΎααααα
ααααα§αααααααΆααααααΎα (Breaker hot conductor)
αα αααα»αααααα·ααα»αααΆααααααααααααΈααΆα αααΎα ααΆααααααΆααααααααααΎααα ααΆααααα»ααααα’αααααααΆααα’αΆα ααΎααα αα·αααΆαααααααααα ααααααααΎαααααα’αΆα ααααΌαααΆααααααα’ααααααααΆαα‘αΎααα·α αα·αααααΎααΆααααααααΎααααααΆαα αααα (Ungrounded conductor) αα αααα»ααα·ααΈααΆααααααααααΆαααααααα½αα ααα½αα αααα αΎαααΆααΌαα ααα»αααααΆααααααΆ βααααααΆααααααΆααΆααααα’ααααΆααααΉαβ αα·ααααααααααΆαααααααΆααααΆααααααα’ααααααααΆααααααααααα»ααααα·ααΆααααααα.
ααααα·αααΎα’ααααααα»ααα½ααα»α α¬ααααΆααααααΌααα»αααΆαα ααΌααααααΆααααααααααΎαααΈαα½αααα»ααααααααΆα αααΆα αα α αΎααααααααααΆαααα»αααΆαααααααΆαααααααΎα§αααααααααααααααααααα.
ααααααααΎαα αΌα (Line) αα·αααααααααΎαα αα (Load) αα ααΎααααΈααααΎα GFCI

ααααΈααααΎα GFCI ααααΎα±ααααΆααααααα’ααααααααΆα Line/Load ααΆααααααΆαααΆααααααΆααααΆαα·αααα.
| ααααΆααΈα | αα»αααΆα | ααΎααΉαααΆαα’αααΈααΎαα‘αΎαααααα·αααΎααααΆαααααααα»α? |
|---|---|---|
| LINE (ααααααααΎαα αΌα) | ααα½αα ααααα’αααα·αααΈα αΌαααΈααααΆααα ααα αΆαααααΎα | α§αααααα’αΆα ααΉααα·αααααΎαααΆαα‘αΎααα·α α¬αα·αα’αΆα αααααααΆαααΆαααΆαααΆαααΆαααααΉααα»α |
| LOAD (ααααααααΎαα αα) | αααααΌαα αααααα ααΆααααααΈααααΎαααΆααααααααΆααααααΆαααΆαααΆααααα GFCI | ααααΈααααΎαααΆααααααα’αΆα ααΆαααααααΆαααΆαααΆα α¬ααΆα αααααΎα ααααα·αααΎααααΆαααα·αααααΉαααααΌα |
αα ααΎααααΈααααΎα GFCI ααα ααααΆααΈαααααα αΌα (Line terminals) ααΊαααααΆαααααααααΆαααα αΌαα ααααΆααΈαααααα αα (Load terminals) ααααΌαααΆαααααΎαααα ααααααα’αααα ααα±ααα§ααααα GFCI ααΆαααΆαααααΈααααΎααααααααα αααααααΆααααααααααααααΈααα»αααααα ααααα·αααΎαα·αααΆααααααΌαααΆαααΆαααΆααα αααααααΆαααααααα ααααΆααΈαααααα ααα’αΆα αα»αα ααααααα·αααααΎααααΆααααΆα ααααααΆαααΆαααααΆαααααα§αααααα.
ααααα»αααΈααααΈααααΎααααααααΆα αααααααΆααΈαα’αΆα ααααΆαααααααααΌαααΆααααααααα αα»ααααααααΆαααΆαααΆαααΆαααΆαααα ααααΆαα ααααα’αααα·αααΈ (Ground-fault)α.
ααααα αΌα (Line), ααααα αα (Load), ααααα’ααααΆααααΉα (Neutral) αα·αααααααΈ (Ground) αααα»αααααααΈαααα½α
αααααΊααΆαα·ααΈααΆααααααααα½αααΎααααΈαααααΈααΆαααααΆαααα½ααα αααα»αααααααΈααΌαααααΆαα
αααααα
ααα
αΆαααααΎα / ααααααααα (Panel / breaker).
Line αα·α load αα·αααααΆα’αααΈααααΌααααααΆαα ααααα’αααα·αααΈααααααΆααα§αααααα Neutral αα·αααααΆα’αααΈαααααααα‘ααα Ground αα·αααααΆα’αααΈααααΌαααααΆαααα»ααααα·ααΆαα.
Line-to-Line αααααΉα Line-to-Neutral
ααΆαααααααααα½αα ααα½αα ααα‘ααααΆαααΆααααααα’ααααααααΆαααααααααΎα αα·αααΆαααΆαααααααα»αα. Line-to-line αα·α line-to-neutral αα·αααααΆα’αααΈααα»ααααααΆααααΆααααΆαααααα ααααα.
| ααΆαααΆααααα | α’ααααααααααααΆ | ααΆαααααΎααααΆααααααααΆα |
|---|---|---|
| Line-to-neutral | ααα»ααααΆαααααα αααααα½α αα·ααααα Neutral | ααααα»αααααΆααααΆααααα½α (Single-phase), ααααααα (receptacles), ααααααααααααΎαααααααΊ, αα·αααααααΈαααααΆ |
| Line-to-line | ααα»ααααΆαααααααααΎαααΈα (Line conductors) | ααααα»αααααΆααααΆαααααα (Split-phase), ααααΆααααΆαααΈ (three-phase) α¬ααααα»ααααααΆαααΆααααααααααΆαααα |
| ααΈααααααααΎααα ααΈ (Line-to-ground) | ααα»ααααΆαααααααααΎααα·αααΈααααα§ααααα (Equipment ground) | ααΆααααααααααααααΆααααΆααααααααΆααααα αΆ ααα»αααααα·αα’αΆα αααα½αααΆααααααΉαα’αααΈααααΆαααΆαααααααΊα (Neutral) ααΆαα‘αΎα |
| α’ααααΆααααΉααα ααΈ | ααα»ααααΆαααααααΊα (Neutral) αα·αααΈ (Ground) | ααΆααααααΆαα½αααααΆαααααα·αααΆααα αααα»αααααααΈαααααΆααα»ααααα·ααΆα ααα»ααααααΆα’αΆαααααααΎααααα»α ααΆααααααΆααααααααααΎα αα·αααΆααα ααΆαααααααααααα |
α§ααΆα ααα αα αααα»ααααααααααααα ααααΆααα α’αΆαααα·αααΆαααΎαααΆα αααΎα ααααααΈααΆααΆααΌαα α’αΆα ααΆαααααααα»ααααα αα 120 V αααΆαααααααααΎααα·αααααααΊα (line-to-neutral) αααααααααααααα»αααααα½αα ααα½αααααΎααααΆαααααα αα 240 V αααΆαααααααααΎααα·αααααααααΎα (line-to-line)α αα αααα»αααααααααααααα ααααααα»ααααΆαααααααααΎααα·αααααααΊαα’αΆα ααΆααααα αα 230 Vα ααΌαα’αα»ααααααΆαααααααα»ααααααααα αα·ααααααααΆαα’αααα·αααΈαααα»αααΌαααααΆααααααΆααααΆαααα‘αΎαααΆααααΆααααΆαα·α αα α.
αααααΌααααααααααααΎαα ααΆααααα»ααααααΆααααααααα αα·ααααααΆααααα»ααΆαα α»ααααααααααα
αααααααααααΎαα’αΆα αα½αααΆα ααα»ααααααΆαα·ααα½αααααΌαααΆαααααΎααΆαα·ααΈααΆααααααααααα’ααααααααΆααααα½αααααααααα ααααααααααΆααααααΆαααααΎααααΆαααααααΆαααΆααα»αααααΆαα ααΆααααααα α’αΆαα»ααΆαααααΆαααα‘αΎα αααααααααα αα·αααΆααΎααααα ααααααααΌαααΆααααααα’ααααααααΆαα‘αΎααα·αα¬α’ααα.
| αα»αααΆα | ααααα»ααααααΌαα ααΆααααααααΆαα’αΆαααα·α (U.S.) | ααααα»ααααααΌαα ααΆααααααααΆα IEC | ααΆααααα»ααααααααα |
|---|---|---|---|
| ααααααααΎα / αααααααααΆαα αααα (Line / hot) | ααααααα αααα α ααα α¬αααααααααααααααα·ααααααΆαααα α¬ααααααα | αααααααα αααα αααααα α’αΆααααααα ααΆαα αααΆα (Phase) | ααααΌαααααααΎααΆααααααααααΆαα; αααα’αΆα ααΆαααΆααα»αααααΆ |
| α’ααααΆααααΉα | α α¬ αααααα | ααα | αα ααα’αΆα ααΆαα ααααα’αααα·αααΈα αΌα |
| ααααααΈ / ααααααΆαααΆα (Ground / protective earth) | ααααααα α¬ααααΆααααα (ααααΆαααααα) | ααααααα/ααΏα | αα·ααα½αααααΎααΆααααααΊα (Neutral) α‘αΎα |
| ααααααααΎαααΆαα αααααα ααΆααααααα»α (Load hot) | ααΆααΏααααΆαααααααα»ααααα»ααααα½αααΆαα½ααααααααααΆαα αααα (Hot conductors) | Often same color family as phase conductors | No universal βload colorβ exists |
If a previous installer used nonstandard colors or failed to re-identify conductors, a color-based guess can be wrong. This is especially common in older homes, mixed wiring systems, control panels, and repaired circuits.
How to Identify Line, Load, and Neutral Safely

The safe method depends on the circuit and local practice, but the general logic is:
| ααα αΆα | What a Qualified Person Checks | α ααα»α’αααΈααΆαααΆααΆααααΆαα |
|---|---|---|
| 1. Turn off and secure power before touching conductors | Breaker, disconnect, lockout where required | Prevents shock and accidental energization |
| 2. Inspect terminal labels | LINE, LOAD, L, N, input, output, source, equipment markings | Device markings are more reliable than assumptions |
| 3. Label wires before removing old devices | Tape or tags | Prevents losing line/load identity during replacement |
| ααααΎα§αααααααΆαα α¬αααΆααααΈααααααααααααααα | αααααΆααααΈααααΆαααααααααΆααααααααααΆαα ααααα’αααα·αααΈ αα·αααααααα»α | ααααααα»αααΆαααααααααΎα (Line), ααααα’ααααΆααααΉα (Neutral) αα·αααααααΈ (Ground) |
| ααααΎααΆαααααααααα»ααααααααααααααΆααα»ααααα·ααΆαααααα»ααααα | α’αα»ααααααΆαααααααααααΆαααΆααααα αα·αααααα·ααα»ααααα·ααΆαααααα§αααααααΆααα±ααααΆαααααΉαααααΌα | ααΆααααααααααααααααΆαααααα»αααΆαααΆααααα |
| αααααααααΆαααααααΆααααΈααΆααααααΆααααααααααΎα | ααΆαααααΎαααΆαααααΉαααααΌα ααΆαααΆαααΆααααααααΆαααααα (Downstream) αα·αααΆαααΆαα‘αΎαααααα αα»αααααααααΈ α¬ααΆαααααΆα αα αααααααααααααααααααα· (Tripping) | αααααΆααααΆα§αααααααααΎαααΆαααΆαααΆαααααααα»α |
αα»αααααΎααΆααααααΆααααααααααΎααααααΆαααΆααααααααα»αααααααααΆαα ααααα’αααα·αααΈα ααααα·αααΎαααα’ααααααααααΎαααΆαααααα αααΎα ααααααΊααα½α (shared neutrals) ααΆαααααΌαααααΎαα αααΎααααααα ααααα’αΆαα»αααΈαααΌα α¬ααααααααΎαα αΆααααααα·αα αααΆααααΆαα ααΌαα α ααΆαα’αααα·αααΈαααααΆαααααΆαα.
ααα α»αααΌαα αααα»αααΆαααααααααα Line, Load αα·α Neutral
ααα α»αααΈ α‘α ααΆααααα ααα‘αααΆαααα Load ααΊααΆαααα Neutral
αααα Load ααΆααααααΆααΊααΆαααααααααΆαα ααααα’αααα·αααΈα αααα αααααααααααααα§αααααααααΎααααΆααα α αααα Neutral ααΊααΆαααααααα‘ααα αα½αααΆαα·ααααααΆααααααΌα ααααΆααα.
ααα α»αααΈ α’α ααΆααααααααΆαααααααααααααααΆαααα Neutral
αααα α¬αααααααααααααΌαααΆαααααΎααΆααΌαα αααααΆαααααα Neutral αα αααα»αααααααααααΆα αααΎααααααα ααααα’αΆαααα·α ααα»ααααααΆαααααΈαααα’αα»ααααΆα αα·αααααΈαα·αααααΉαααααΌααααααααααααα’αΆα ααααΌαααΆαααααΎαα»αααΈαααα ααααΌααααααααααααΆαααα»αααΆαααααααΆααΆαα·α αα α.
ααα α»αααΈ α£α ααΆααααααΆαααααα Line αα·α Load αααα GFCI α αααΆαααααΆ
α§ααααα GFCI α’αΆαααααααΎααΆαααααΎααααΆααααααΆααΈα Line/Load α±ααααΆαααααΉαααααΌαα ααΆααααααΆαααααααα»αα’αΆα αααααΆαα±ααααΆααααα αΆαααα»αααΆα Reset ααΆαααΆαααααααΆαααΆαααΆααα αααααααΆαααααα (downstream) α¬ααΆαααΆα αα ααααα’αααα·αααΈααααα·αααΆαααααααα»αα.
ααα α»αααΈ 4α ααΆααααααΆαααα Neutral ααΆααα»ααααα·ααΆααααα»αααΆαααα
αααα Neutral α’αΆα ααΆαα ααααα’αααα·αααΈα αΌα αα·αα’αΆα αααααααααααααΆαααααα»αααααΈααΆα ααααα Neutral, ααΆαααααΎαααα Neutral αα½αααααΆ α¬ααΆααααααΆαααααααα»αα ααΌαα αΆαααα»ααααααααααααααααααΆα’αΆα ααΆαα ααααα’αααα·αααΈαα αΌαααΆααααααΆααααααααααΆαααα½α ααΆααα.
ααα α»αααΈ 5α ααΆαααααΎαααα Ground ααΆαααα Neutral
αααα Ground ααΊααΆαααααα»ααααα·ααΆα αα·ααααααΆααααΌααααα‘ααααα ααααα’αααα·αααΈααααααΆαααααα ααΆαααααΎαααα Ground ααΆαααα Neutral α’αΆα ααααΎα±ααααααΌα Ground ααααα§αααααααΆαα ααααα’αααα·αααΈ αα·αααααααΆαααααααααΆααααααΆααααα.
ααα α»αααΈ 6α ααΆααα·αα’αΎααΎααΉααααααΆαααααΆααααΎα§ααααα
αα»αααΆαα, αααααααα (Breakers), GFCI, RCBO, αα»αααΆααααα (Contactors) αα·αα§αααααααΆααααααΆα αα αααα (Disconnects) α’αΆα ααΆααααααΆαααααΆαα Line/Load α¬ Input/Output ααΆααααΆααα ααΌαα’αα»ααααααΆαααααΆααααΆααααααΆαααααα αα·αααΆαααααΆαααααααα·αααααΆαα·α αα α.
ααΈααΆααααα Line αα·α Load ααΆαααΆααααααΆαααα αααα»αααα·αααα’αααα·αααΈ
ααΆααααααα’ααααααααΆαααααααααΎαα αΌα (Line) αα·αααααααααΎαα αα (Load) αα·ααααααΆαααα αΆαααα αααα»αααααααααααααααααΎααααα ααααΆαααα»αααααααα ααΆααΆαααΆααααααΆαααα αααα»αααααααααα·ααα VIOX ααΆα αααΎαα
- αααα»α MCB αα·αααααααΈα§αααααααΆααααααΎα (Breaker) ααΆααααααΆααααααααααΎαα αΌα αα·αααααααααΎαα αα αα½αααααααα·ααα αααααααααΆααα αα·αααααααΈαααααααΌαααΆαααΆαααΆαα.
- αααα»α RCBO ααααααΈ ααΆααααααΆααααααααααΎαααΆαα’αααα·αααΈ (Live) αα·αααααα’ααααΆααααΉα (Neutral) α±ααααΆαααααΉαααααΌαααΊααΆαααΆααααααΆαα αααααα§αααααα αΆαααααααΆααα αΌαα ααααα’αααα·αααΈααααα ααα (Residual-current sensor) ααααΌααααααα½ααα·αα·αααααΎααααα αααααααααΆααααααα.
- αα αααα»αααααΆαααααααΆ (Control panels) α α»αααααααααΎαα αΌα αα·αα α»αααααααααΎαα ααααααα§ααααααα»αααΆααααα (Contactor) αααααααααΌαααΆαααααααΉαααααΌααα ααΆαααααΌααα α§αααααααααα α¬ααααααΈααααΎαααααααΊα.
- αα αααα»αααΆαααΆαααΆαααΆαααΎαα‘αΎαααα»αααααΆαα (Surge protection) ααΆααααααΆααααααα αααΆα (Phase) ααααα’ααααΆααααΉα (Neutral) αα·αααααααΈααΆαααΆα (Protective earth) ααΆαα₯αααα·ααααΎααΆαααααΎαααΎαα§ααααα αα·ααααααααααΆαααα‘αΎαα.
α αααΆααααααΌαααΊααΌα ααααΆα ααΌαα’αΆαααΆααααααΆαααα ααΎα§ααααα αα·αα·αααααΎαααααΆααααΆαααααααααΎα αα·ααααααααααΆααααααααΈα±ααααΆαα αααΆααααΆαααα»ααααααΎαα ααααα’αααα·αααΈα.
αααα½ααααα½αααΉαααΆαα
ααΎα’αααΈααΆααΆααα»αααααΆαααΆαααααααααΎαα αΌα (Line) αα·αααααααααΎαα αα (Load)?
Line ααΊααΆαααααααααΆααααααα αΌαααααΆααα§αααααα Load ααΊααΆαααααααααααα ααααΆααααα ααΆααα§ααααααααααΆααααααΆαα α¬ααααααΈαα αααααααΆααααααα ααΆαααααΆαααααααΊααΆαααααα ααΉαα§αααααααααααα»ααααααΆααααααααααΎαα.
ααΎαααα Load ααΌα ααααΆαα ααΉααααα Hot α¬αα?
αααα Load ααΊααΆαααααααααΆαα ααααα’αααα·αααΈαααααΆααααΈααααααΆαααα»αααΆαα, αααααααα (Breaker), GFCI, αα»αααΆααααα (Contactor) α¬α§αααααααααααααααααααααΌαααΆααααα ααΆααααααα»αα αααααΆαααΆαααΆααααα ααΆαααααΆ βLoadβ ααΊαααα αα ααΎααΈααΆαααααααααα αααα»αααααααΈ α ααααα―ααΆαααααΆ βHotβ ααΊαααα αα ααΎαααααααααΆαα ααααα’αααα·αααΈ (Ungrounded conductor)α.
ααΎα’αααΈαα ααΆαααα Load αα ααΎαα»αααΆαα?
αα ααΎαα»αααΆαα αααα Load ααΊααΆααααααααααααΌαα ααααα ααααΈαα»αααΆαααα ααΆααα’αααΌαααααΎαα¬α§αααααα’αααα·αααΈα ααΆααΆαα αααααα αααααααα»αααΆαααααα·ααααα»αααααΆαααΆαααΎα (ON) αα·αααααΆαα ααααααααααΆαααα»αααΆααααααααα αααααααα»αααΆαααααα·ααααα»αααααΆαααΆααα·α (OFF)α.
ααΎα’αααΈαα ααΆαααα Neutral?
αααα Neutral ααΊααΆαααααααααααΆαααα ααΉαααΈ (Grounded circuit conductor) αααααΆααα½ααΆααΈααΆαα αααααααα‘αααα ααααααα·ααααα»αα’αα‘α»ααααααααα·ααααα·ααΆαααααααΆα ααΆαα½ααααααααααααΈα’αααα·αααΈ ααα»αααααα·ααα½αα αΆαααα»αααΆααΆααααΆααααααααααΆαααααααα.
ααΎαααα Neutral ααΆααα½ααΆααΈα’αααΈαααα?
αααα Neutral αααααααΌαααααΌααααα‘αααααα·ααααααΆααα ααααα’αααα·αααΈα αα αααα»αααααααΈ AC ααΆαα αααΎα α ααααα αΌαα ααααΈαααα Line ααααααΆααααααα»α (Load) α αΎααααα‘αααααα·αααΆαααααααα Neutralα.
ααΎαααααααα»αααααα»α (load wire) ααΆααααα’αααΈ?
αα·αααΆαααααααααααΆαααααααααΆαααααααααα»αααααα»ααααααα αα αααα»αααααααααααΆα αααΎα αααααααα»αααααα»αααααΎααααααα»ααααα»ααααα½αααΆαα½ααααααααααΆαα αααα (hot conductors) ααΌα ααΆααααααα α¬ααααααα ααα αααα»αααααααααααααααααΎαααΆααααα’αΆαααα·αα ααΌααααααα’ααααααααΆαααΆαααααα’ααααΎαα»αααΆαααααααααΈ αα·αααΆαααααΎαααααααΆαα·α αα αα»αααΉαααα’ααααΎααααααα½ααα»αα.
ααΎααααα‘αΆα (line) αα·αααααααΊα (neutral) ααΆααααα’αααΈ?
αα αααα»αααααααααα’αΆαααα·αααΆα αααΎα ααααα‘αΆα α¬αααααααααΆαα ααααααΆααΌαα ααΆαααααααα α¬ααααααα α α αΎαααααααΊαααΆααΌαα ααΆααααα α¬αααααααααα αα αααα»αααααααααααΆααααααααΆα IEC ααΆα αααΎα ααααα‘αΆαα’αΆα ααΆααααααααα αααα α¬αααααα α αΎαααααααΊαα αααΎαααααΆαααααααα α αααΆαααααα»αααααα αα·αααααΆαααΆαααααααααΎααααααΆαααααΆααααααΌααααααα½ααα·αα·αααα.
ααΎα’αααΈαα ααΆααα»ααααΆαααααα‘αΆααα·αααααα‘αΆα (line-to-line) ααΎαααααΉαααα»ααααΆαααααα‘αΆααα·αααααααΊα (line-to-neutral)?
Line-to-neutral ααΊααΆααα»ααααααΆαααααΆαααααα‘αΆααα½α αα·αααααααΊαα Line-to-line ααΊααΆααα»ααααααΆαααααΆαααααα‘αΆαααΈαα ααα»α Line-to-line ααααΌαααΆαααααΎααΆααΌαα αααααΆααααααα»ααααααΆαααΆαααααααα α¬ααααααααα αααΎαα αααΆα (multi-phase systems)α.
ααΎα’αααΈαα ααΆ Line, Load, Neutral αα·α Ground?
Line ααΊααΆααααααΆαααΆαααα αΌααα αααα»αα§αααααα Load ααΊααΆαααααααααΌαααΆαααα ααααΈα§ααααααα ααΆααααααα»ααααααΆααααααΆααα Neutral ααΊααΆαααααααααΌαα αααααααα‘αααα ααααααα·αα Ground ααΊααΆαααααααααααααΌααα»ααααα·ααΆααααααΆααα ααααααα ααααΆα (fault current) α αΎαααΆααααααΆαα·ααα½αααΆαα ααααααααα·ααααα·ααΆαα αΌαααααααΆαααααααα.
ααΎα’αααΈαα ααΆ Load αα·α Line αα αααα»α MCB?
αα αααα»αααααααΈ MCB ααααα Line ααΆααΌαα ααΊααΆαααααααααααααααααΆααα α αΎαααααα Load ααΊααΆααααααΈαααα ααααΆααααααααααΌαααΆαααΆαααΆαα ααΌαα’αα»ααααααΆαααΆααααααΆαα αα·αααΆαααααΆαα’αααΈααΆααααααΆαααααααααααΆαααααΌαααα§αααααααΆααααααΎα (Breaker) ααΆααααΆααααΆαα·α αα αααααααΆααααααααΈααΆααααααΆααΈα αα·ααααααΌαααΆαααα‘αΎαα’αΆα ααΆαααΆααα»αααααΆα.
ααα ααααΈααααα·
Line, Load, Neutral αα·α Ground αα·ααααααΆααΆααααααα’αΆα ααααΎαααα½αααααΆααΆαααα. ααααααααα (Line) ααΆααααααΆααΆαααααααααααααΆαααα αΌααα αααα»αα§αααααα. αααα»α ααΆααααααΆααΆαααααααααα ααα ααααΈα§ααααααααα. α’ααααΆααααΉα ααΊααΆαααααααα‘ααααααααΆα. Ground ααΊααΆαααααα»ααααα·ααΆααααααΆααααΆαααΆαααΆαααα ααααΆαα ααααα’αααα·αααΈα.
αααααΆααα’αααααααααααααααααΆααΆααααααα’ααααααααΆαααααααααΎα αααααααααααΆαααααα»αααΊα αα»αααΉαααα’ααααΎααααααα½ααα»αα. ααΌαααααΎαααααΆαααααΆαααα ααΎα§ααααα ααααααααααΈαα½ααΆααΈααααααααΈ αα·ααααααααααΆααααΆαα½αα§αααααααααααααααααΉαααααΌαα αα ααααααααααααααΎααα·αα αααΆααααΆαα ααΌα ααΆα α αΆαα α¬ααααΆαααα ααΉαα§αααααααΆαααΆαααΌα ααΆ GFCI, RCBO α¬α§αααααααΆααααααΎα (Breakers) αααααΎααααααΆααα»ααααα·ααΆααααα»αααΊααααΌαα±ααααΆαα’αααα·αααΈαααααΆαααααΆααααα½ααα·αα·αααααΆααΆαα»ααα·α αα»αααΉαα αΆααααααΎααααααΌαα ααααα’αααα·αααΈα αΌααααα»αααααααΈα.