α ααααΎααα ααα α’αααααα·α Busbar ααα’αααα»ααααααΆααααΌα’αααα·αααΈ
αααααΆααααΌα’αααα·αααΈ ααααααααα§αααααααΆααααααΎα αααα’ααα ααα αΆαααααΎα αα·αααΌα ααα αΆαααΆαααα’αααα·αααΈααααααα»αααΆα α’αααααα·α Busbar αααααααΆαααααα»ααα·αααααα»αααααααΆαααα»αα αα»ααααααααααα½ααααααα.
ααααααΆα’αααααα·αα§αααααααααΌαααααΎα (Switchgear) ααααΆαααα·ααααα ααΌα ααΆ Schneider Electric, Siemens, ABB, Eaton αα·α Legrandα αααααααααΆα’ααααααααααααα Busbar α¬αααααααααααααΆααααΆαααα―αααα ααΌα ααΆ Mersen, Rogers, EAE αα·α Altechα α ααααα―αααα»αα αα»αααααααααααΌα ααΆ VIOX Electric αααααααααΆαααααααααΆαααα ααΎααααΏααααααΆααααΌα’αααα·αααΈααααααα»αααΆα, Busbar αααααΆαα MCB, Busbar αααααααααα»α (Pin-type), Busbar αααααααα (Fork-type) αα·ααααααααααααααΆααα§αααααααΆααααααΎαα.
ααααα·αααΎα’ααααααα»αααααααα Busbar αααααΆααααααααααΌα’αααα·αααΈ αα»αααααΎαααΎαααααΆαααααααααΆαααΈα αα ααΌααα·αα·αααααΎααααααα Busbar ααΆααααααα αα»αααΆαααααΆαα α¬α’αΆαα»αααΈαααΌα ααΆααααααααα α α ααααααααα (Pitch) ααααα·αα ααααα’αααα·αααΈ ααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit) ααΆαααΆαααΆαα’ααΈααΌα‘αα ααΆαααααααΆααΆαα½αα§αααααααΆααααααΎα αα·αα―αααΆααα αα αααααα.
αααααΉαβαα
- βα’αααααα·α Busbarβ ααΊααΆααΆαααααααααααααααΆααααααΌααααΌααΆαα. ααΆα’αΆα ααΆααααααΆ Busbar αααααααα·αααααααααΆαα MCB, Busbar αααααΆααααΌα ααα αΆα, αααααααα Busbar Trunking, Busbar ααααααααααΆαα (Laminated), Busbar ααααΆαα α¬ Busbar αααααΆαααααα’ααα ααα αΆαααααΎαα.
- Busbar αααααΆααα§αααααααΆααααααΎαααααΌαααΆαααΆαααααααΆαααααΆααααΆααα. αααααΆαααααα ααααααααααΆααΈα ααΆαααααααα ααΆααααααααααααΆααααΆα αα·ααααααΈα§αααααααΆααα αααα (Breaker) ααααΌαααααααΌααααααααΆα.
- αα»αααΆααααααΆαααααΆαα (Busbar) αααα»αααΌααααΎαα’αΆαααααααΎαααααΆαααααΆαααα ααΆααααααααα α ααΆαααΎαα‘αΎαααααα αα·αααΆαααααααααα§αααααααΆααα ααααα. αααΆαααΈα αααααΈααααααα·ααααααααααΆαααα ααααα·αααΎα ααα»α αααααΆαααααΆααααΆαααααΆαα αα·αα§αααααααΆααα αααααα·ααααΈααααΆααΉαααααΆα.
- ααααααααΆααααααααΆα IEC αα·α UL ααΆαααΆαα―αααΆαααααα»ααααααΆα. αααααααΆα IEC 61439, UL 67, UL 857, UL 508A αα·αααΆαα α»ααααααΈααα·αααααΆααααΆααα’αΆα ααΆαααΆααααααΆααα’αΆαααααααΎααΈααααΆα αα·αααΆαααααΎααααΆααα.
- VIOX ααΆαααΆαααΆααααααααααα»ααααααΆαααααΆαααααΆαααα MCB αα·αααααΏααααααΆααααΌααααΎαααααααα»αααΆαα. αααααΆαααααααααα Busway ααααΆααα α¬αααααααααααααΌαα ααααααΆααααΆαααααΆαα αααΆαααΈα αα§αααααααααΌαα αααα (Switchgear) ααααΆαααα·αααααα’αΆα ααΆαααΆαααΉαααΆαααΆαα.
αααααααααΎαααααΎαααΎααααα»αα αα»αααα·ααααΆαααααΆααααΆααααα
αααααΈααααα·ααααααΆα αααΆααααααΆαααααααα α·ααααααααα»ααα ααΆααααΎααΆααααααααααααα»αα αα»αααα·ααααΆαααααΆαα (Busbar) ααΈααααααααααα’ααααα·α ααΆαα·ααααααααΆααααΌα’αααα·αααΈ ααΆαα ααα αΆαα§αααααααΆααααααΎα (Circuit breaker) αααΆαααααΆαααααααΆαα MCB ααααααααααααα»αααααα»α (Load centers) αααααααααΌαααααααα»αααΆα (Low-voltage switchgear) αα·αααΆαααα‘αΎαααααα OEMα.
| αααααΆααααΎαααΎα | α ααα»α’αααΈααΆαααΆααΆααααΆαα |
|---|---|
| αα·ααΆαααΆαααα·ααα | ααΆααααα αααααΆααααΆαααααΆαααααααααα·α (Comb busbars) αααααΆαα MCB, αααααααααααααΌαααΆαααααΆααααΆαααααΆαα (Busbar trunking), αααΆαααααΆαααααααΆαα (Laminated busbars) αα·ααααΆαααααΆαααααααα·αααΆααααααΌαααΆαα |
| ααααα·αααΆααααααα’αααα·αααΈ | ααααα·αα ααααα’αααα·αααΈ ααααα·αααααααα»α αα·ααααααααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit) ααααΌαααααααααΆαααΆααα ααΆααααααΌα’αααα·αααΈα |
| ααΆαααααααΆααα§αααααααΆααααααΎα (Breaker) | αααΆαααααΆαααααααΆααα§αααααααΆααααααΎαααααΌαααααΆαααα αααααααααΉααα ααΆαααααααααΆααΈα αα·ααααααΆαααΆααααΆααα |
| αα»αααΆααααααΆαα | αα»αααΆαααααΆαα αα»αααΆαα’αΆαα»αααΈαααΌα ααΆαααααα αα·αααΆαααΆαααΆαααααα αα»αααααααα₯αααα·αααααααΆαααΎαα‘αΎαααααα αα·αα’αΆαα»ααΆαααααΎααααΆααα |
| ααΆαααΆααααααΆααααααααΆα | α―αααΆα IEC/UL ααΆαααααααα αΆαα·αααααααΆαα’αα»ααααααααα |
| ααΆαααααΌαααΆααααα | αααα»αα αα»αααα·αα§αααααααΎα (OEMs) ααΆααΏααααααΌαααΆααααααα αααααΆα α ααα½ααααΌα ααΆααααα αααααΆααααΆα α¬ααΆαααα ααα αααα·ααα |
| ααΆαααααααααααααΆααα | α’αααα ααα αΆα αα·αα’αααααα‘αΎαααααΆαααααααΆααααΌαααΆαααααααααααααααααααααΆααααα·αααΆα αα·αααααααΆααααα»αααΆααααα½α |
| αααα½ααα αα ααααα | ααΆαααααΎαααΎαααααΉαααααΌααα½αααΆαααΆαααΆαα‘αΎαααααα ααααΆαα ααΆαααα»αααααααΆαααααα αα·αααΆααααΆααααααα»αααΆααααα½ααα·αα·ααα |
ααΆααΆααααααααααααα»αα αα»αααα·ααααΆαααααΆαα (Busbar)

| αααα»αα αα»αααα·α | αααααΆαααααααΆαααααΆαααα (Main Busbar) | ααα’αααα»ααααααΆαα | ααααααααααΆααα’ααααα·α |
|---|---|---|---|
| Schneider Electric | ααααααααα ααα αΆαα’αααα·αααΈααααααα»αααΆα α αααααΆαα ααΆααααααααααΌα’αααα·αααΈ αα·ααααααααα Busbar trunking | ααααααααΆαα·ααααααα αα·αα§ααααΆα ααααααααΆααα | ααΆααα½ααααα αΌαααααααααααααΉαααΆα; ααααΌααααααααααΆαααααα»αααα·ααα αα·αααΆαα’αΆα ααααΆααααα»ααααα»α |
| αααΈααα | ααααααααααααΆαααα»αααΆαα (Switchgear) ααΌα’αααα·αααΈ (Panelboard) αα·ααααααααα Busbar trunking | ααΆαα ααα αΆαα’αααα·αααΈαααααΆααα§ααααΆα αααα αα·αα αααααΆαα ααΆαααααααα | ααΆαααΆαααααΆααααΎαααααααααααααΆααα ααΆα‘αΎαααΆααααααΌαααΆα; αα·αααΌααααααααΎαααΆαααααΆαα (Comb busbars) αααααΆαα MCB ααΌαα |
| ABB | ααα·αααα’αααα·αααΈ ααΆαα ααα αΆαααααααα»αααΆα αα·αααααααααα§αααααααΆααααααΎα (Breaker systems) | ααααααααΌα’αααα·αααΈ αα·αααααΆαααα»αααΆαα (Switchgear) ααααα·αααα | αααααααα αααααααααΆαααααΆαα (Busbar) αα·αα§αααααααΆααααααΎα (Breaker) ααααΌαααΆααα·αααΆαααααααααααα½α |
| α’ααΈαα»α | ααΌααααΎααα (Load centers), ααΌαα»αααΆαα (Switchboards), ααΌα ααα αΆαααααΎα (Panelboards), αααααααααααΆαααααΆαα (Busway) | ααααααα ααα αΆαααΆααααα α’αΆαααα·αααΆαααΎα αα·αααααααα ααα αΆαααΆαααααα | ααΆαααΆαααααΆαααα ααααααααααααααααα UL αα·αααΆαααααααΆααααΌααααΎαααΆαααΆααααααΆαα |
| Legrand | αααααααααααΆαααααΆαα (Busbar trunking), ααΆαα ααα αΆαααΆαααααΆαααΌααααΎα, α αααααΆαα ααΆααααααααα’αααα·αααΈαααα»αα’ααΆα | α’ααΆαααΆαα·ααααααα αα·αααΆαα ααα αΆαααΆαααααΆααα ααΆαααααααα | ααα’αααααΆααααααααααα ααα αΆαααΆααααααα»αα’ααΆα αα·ααααααααααααΆααααααααΆα |
| ααΊαα·α | αααΆαααααΆαααααααΆαα (Laminated busbars), α’αα‘α·α ααααΌαα·α ααΆααα, α ααα»ααααΈα (Fuses), ααααααααααΆαααΆα | ααΆαααααα’αααα·αααΈ (EV), α’αα‘α·α ααααΌαα·α ααΆααα, ααΆααααααΎαα‘αΎααα·α, αα·αααααΏαααααα»ααααααΆαααααα·αααααΆαααααα | ααΆαααΆαααΉαααΆααααααΆααααΆααααααΆααααΆαααααα·ααααααα αα·ααααααααΆααααααΆαααααααααΆαααααααΆααα§αααααααΆααααααΎα (Busbar) ααα»ααααααα |
| Rogers | αα αα αααα·ααααΆ Busbar ααααααααΆαα (Laminated busbar) αααααΆααααααΏαα’αα‘α·α ααααΌαα·α αααααΆαααΆαααααααα | ααΆαααααα’αααα·αααΈ (EV), α’ααΈαααΊαααα (Inverter), ααααααααα’αΌαααΆα, α’αΆαα»α, αα·ααααααααααααααααααΆααα | ααα’αααα»ααααααΆαααα·ααααααα Busbar ααααααααΆαα ααΆααΆαααααα Busbar αααααΆααααΌααααΎααααααααΆα |
| EAE Elektrik | αααααααααααααΌαααΆαααααΆα Busbar (Busbar trunking) αα·αααααααααα ααα αΆαααΆααα | αααα αααα§ααααΆα αααα ααααααααααα·αααααα αα·αα’ααΆαααΆαα·ααααααα | αααααααααααΆααααααααααααααΌαααααααΎααααααΌαααΆααα (Busway) αα·αααααααα ααα αΆαααΆαααα’αααα·αααΈααααΆααα |
| αααα»αα αα»α Altech Corp | ααααααααααααΌαααααααΎα DIN (DIN rail) αα·ααααααααααααΆαααααΆαα (Busbar) αααααΆααααΌαααααΆ | α’αααααα·αααΌα’αααα·αααΈ αα·αα’αααααα·αααααΏααααΆαααΈααα α’αΆαααα·αααΆαααΎα | ααΆααααααααααααααΆααααΌαααααΆααααααΌαα»α αα·αααΆαααααααααααααααΏααααααΆαααααααααααΆααααααααΆα UL |
| VIOX α’αααα·αααΈ | αααΆαααααΆαααααααΆαα MCB (MCB busbars), αααΆαααααΆαααααααααααα»α/αα (pin/fork busbars), ααααΏααααααΆααααΌα’αααα·αααΈ αα·αααααΏααααααΆααα ααα αΆαααΆαααααα»αααΆα | α’αααααα·αα§αααααααΎα (OEMs), α’αααα ααα αΆα, α’αααααα·αααΌα’αααα·αααΈ αα·αααααΆααα ααα αΆαααΆααα MCB | ααΆαααααΎαααααΉαααΆααααααΆααααΆαααααααααααααααααααααΆααααααα, αααΆαααααΆαααααααααα·α (comb busbars) αα·αααααΏααααααΆααααα»αααΆα |
α’αααααα·α Busbar ααααΌαααΆαα α‘α
1. Schneider Electric
Schneider Electric ααΆαααΆαααααΆαααααα»ααα ααααααα’ααααα·ααα·αααααααα»αααααααααααΆαααααΆααααΆα ααααα‘ααααααα ααα»ααααααΆααααΆααααααααα ααα αΆαααΆαααα’αααα·αααΈααααααα»αααΆαααααααα αααααααα Busbar trunking, ααααααααααΌααααΎα (panelboard), ααΆααα½ααααα αΌαα§αααααααααΌα (switchgear) αα·αα§αααααααΆαααΆααααααΆαααΆααααααααααα½αααααΆα.
ααα’αααα»ααααααΆααα α’ααΆαααΆαα·ααααααα, ααΆαα ααα αΆαααΆααααααα»αα§ααααΆα αααα, ααααααααααα·αααααα αα·αααααααααα ααα αΆαααΆαααααααααα»αααΆαααΆααααααααΆαα.
α’αααΈαααααααΌααααααααααΆααα αααα»αααα·ααα, αααααααΆααααα»ααααα»α, ααααα·αα ααααα’αααα·αααΈ, ααααα·αααααααααΉαααΆαααααα ααααααααΈ (short-circuit rating), ααΆαααααααΆααααΌααααΎα αα·αααΆααΎααααααααααΌαααΆα Busbar trunking α¬ Busbar αααααΆααααααΎαααα»αααΌααααΎαα.
2. αααα»αα αα»α Siemens
Siemens ααααΌαααΆαααΆααααααααΆααΌαα αααααΆααααααααααα ααα αΆααααααΆααα ααΆα‘αΎαααΆαα·ααααααα ααΆααΆαααααΏααααααΆααααΌααααΎαααΌαα α αααααααααααΆααΆαααΆαααααΆαααααα»ααα ααααααααα Busbar, α§αααααααααΌα (switchgear), α§αααααααΆαααΆα αα·αα―αααΆαααααααα αΆαααΆα αααααΌαααααΎαααΆαααΆαααα αααααα½ααααααΆαααΆααααααααααα½αααααΆα.
ααα’αααα»ααααααΆααα ααααααα§ααααΆα αααα, ααααααα αααααΆαα ααΆαααααααα, ααΌααααΎαααα αα·αααααααααα ααα αΆααααααΆααα ααΆα‘αΎαααΆαα·αααααααα.
α’αααΈαααααααΌααααααααααΆααα ααΆααΎααα·ααα Busbar αααααααΌαααΆααααααΊααΆ Busbar αααααΆαα Switchgear, Busbar αααααΆααααΌααααΎα (panelboard), αααααααα Busbar trunking α¬ααααΏααααααΆαααααααΆααα§αααααααΆααα αααα (breaker)α.
3. ABB
ABB ααΊαααααα·αααααα»ααα αααααααα»αααΆααααααΆαααααΆαα (busbar) ααααΌαααΆαααΆααααααααΆααααααα½αααααααααααα§αααααααΆααα αααα (breaker) αα·ααααααα ααα αΆαααΆααα (panel) ααΆααααΌαα αααααΆααα’ααααα·α αααα½ααααααΉααα·ααααααααΉαααααΆ βααΎ ABB ααα·ααααΆαααααΆαααααα¬αα?β ααααα ααα»ααααααΊ βααΎαααΆαααααΆαααααααααΌαααΆααα ααΆα‘αΎαααΎααααΈααΆααααααααααα·ααΆα ααα αΆαααΆααα (distribution platform) αα½αααΆααααααα ABB?β
ααα’αααα»ααααααΆααα ααααααα§αααααααααΌαα αααα (switchgear) ααααααααα ααα αΆαα’αααα·αααΈ αα·ααααααα·ααΈα§ααααΆα αααααααα.
α’αααΈαααααααΌααααααααααΆααα ααΆαααααααΆααα§αααααααΆααα αααα ααααααααααα‘αΎα ααΆαα’αα»αααααΆαααααα αα·αααΆααΎαααΆαααααΆααααααΌαααΆαααααααααααααΆααααααα½ααααααα·ααΆα ααα αΆαααΆααααααααααααα ABB α¬α’ααα.
4. Eaton
Eaton ααΆαααΆααααααΆααααΆαα·ααααααααΆααα’ααααα·αααααααα»αααααααααααΆαααΈα αααΌααααΎα (load center) αα»αααΆααααααααα ααα αΆα (panelboard) αα·αααΆαααΏααΆαααααααΆαααααΆαααααα»ααααααααααα αα αααα»ααααααααα α’αΆαααα·αααΆαααΎα α ααα»α ααααΆαααααα Eaton ααΊααααααααα’αααΌα‘αΌαααΈααααΌααααΌααΆαααααΌααααΎα αααααα ααα αΆα α§αααααααΆααα αααα ααΌαα»αααΆαα (switchboards) αα·αααα·αααααααΌαααααααΎαα’αααα·αααΈ (busway)α.
ααα’αααα»ααααααΆααα ααΌααααΎα (load centers) αααααα ααα αΆα (panelboards) ααΆαα ααα αΆαααΆαααααΆαα·ααααααα αα·ααααααααααααα’ααααΎαααααααΆα ULα.
α’αααΈαααααααΌααααααααααΆααα ααΆαααααααΆαααααααΈα§αααααααΆααα αααα ααΆαααααααααΆαααααΆαα ααΆαααΆαααααααααααα ααα αΆα α ααααααΌα ααΆααααα’αΆα ααΎαααΆα (available fault current) αα·αααΆαααΆααααα§αααααααΆααα αααααααα½αα.
5. Legrand
Legrand ααΊααΆαααΆαααΈα ααααααααΉαααΆααα½ααα αααα»αα αααααΆαα ααΆααααααααα’αααα·αααΈααα’ααΆα ααΆαα ααα αΆααααααα’αααα·αααΈ α§αααααααααααααΎα αα·ααααααααααααααΌαααΆαααααΆααααΆαααααΆαα (busbar trunking systems)α ααΆααααΌαααΆαααααΆααααααααΆααΉαααΆαααα αααα»αααααααα’ααΆαααΆαα·ααααααα αα·αααααΆαααααΆααΆ αααααΆαα ααα αΆα ααΆααααΌαα»α αα·αααααα·αααααΆαααααΆαααα‘αΎαααΆαααΆααααααΆααα.
ααα’αααα»ααααααΆααα ααΆαα ααα αΆαααΆααααααα»αα’ααΆα ααααααααα’αααα·αααΈααΆαα·ααααααα αα·αααΆαα ααα αΆαααΆααααααααΆααα ααΆααααααααα.
α’αααΈαααααααΌααααααααααΆααα αααα»ααααααααα ααΆααΆα‘α»αααΆαααααα α ααααααααα ααΆααα½ααααα αΌααααα»αααΌααααΎα αα·αααΆααΎααααααααααΌαααΆααααααααα Busbar Trunking α¬ααααΏααααααΆαααααααΆααααΌααααΎααααα¬ααα.
6. Mersen
Mersen αααα·ααα αααα»ααααααΈααα αααααΆααααααα Busbar ααΆα αααΎααα·ααααααααΆααααααΆααΆαα ααα αΆαααΆααααααα»αααΌααααΎαααααααΆαααααα αα αααα»ααα·αααααααΏαα’αα‘α·α ααααΌαα·αααΆααα ααΆααααααΎαα‘αΎααα·α αα·αααααααααα’αΆαα»α Busbar ααΊααΆααααααα½αααααΆααα ααΆαααααααααα ααΈα’αα‘α·α αααα·α αα·αααΆαααΆαααΆαα.
ααα’αααα»ααααααΆααα ααΆααααααΎαα‘αΎααα·α ααααααα’αααα·αααΈ (EV) ααααααααα’αΆαα»α α’ααΈαααΊαααα (Inverters) ααΆαααα‘αΎααααααΆαα ααααααααα αα·ααααααα Laminated Busbarα.
α’αααΈαααααααΌααααααααααΆααα ααααααααα’ααΈααΌα‘αα αααααααΆαααααα αααααΆααααΈα’αα‘α·α αααα·α ααΆααα ααΆαααααααααΆαα·α αα·αααΆααααααααααα½αααΆαα½αα ααα»ααααΈα (Fuses) α¬α§αααααααΆαααΆαα.
7. Rogers Corporation
Rogers ααααΌαααΆαααααααΆαααααΆαααΌααααΌααΆαααΆααΆαααα»αα αα»αααα·ααααααΆαααα·αααααααααααα·αααααα αα·ααα αα αααα·ααααΆ Laminated Busbarα ααΆααΆαααΆαααΆαααααααα αααΎαααΆααααααΆααααααΏαα’αα‘α·α ααααΌαα·αααΆαααααααα αα·αααΆααααααααααΆαααααααΆαααΌα ααΆαααΆαααααΎααααΆααααΆαα½α Busbar αααααα Comb αααααΆαα MCB ααΌαα α.
ααα’αααα»ααααααΆααα αααααααααααααΌαααΆαααααααααα’αααα·αααΈ (EV Drivetrains) α’ααΈαααΊαααα (Inverters) αα»αααΊαααα (Converters) ααΆααααα»αααΆααα ααααααααα’αΌαααΆα αα·αααααΏαα’αα‘α·α ααααΌαα·αααΆααααααααα.
α’αααΈαααααααΌααααααααααΆααα ααΆααα ααΆαααααΆαα Laminated Busbar αααααΆααα’ααΈααΌα‘αα αααααΌαααΆαααααΆααααα ααα αααααααααααα (Partial discharge) α ααα»α αααααΆααααααα αα·αααΆααα½ααααα αΌααααααααααΆαα·α α.
8. EAE Elektrik
EAE ααΊααΆαααα»αα αα»αααα·αααααααΆαααα½ααααααααααα Busbar Trunking αα·αααααααααα ααα αΆαα’αααα·αααΈα ααΆααΊααΆαααααΎαααααα’αααααΆαααααααααααααΆαααααααααΉααααααΆαα ααα αΆαααΆαααααα α’ααΆαααΆαα·ααααααα αααα αααα§ααααΆα αααα αα·αα αααααΆαα ααΆααααααααααααααααααα·ααααααα.
ααα’αααα»ααααααΆααα Busbar trunking, ααΆαα ααα αΆαααΆααααααααΆααα’ααΆαααα, αααα αααα§ααααΆα αααα, αα·αα αααααΆαα ααΆααααααααα.
α’αααΈαααααααΌααααααααααΆααα αααααα Busway, α ααααα’αααα·αααΈαααααΆαααααα (Rated current), ααααα·αααΆαααΆα IP, ααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit withstand), αααααααΆααααααΉαααααΎα, ααα·ααΆααΆαααα‘αΎα, αα·αααΆαααΆαααααααα»ααααα»αα.
9. Altech Corp
Altech ααΆαααΆααααααΆαααααααΆααα’αααααΆααααααααΆαααααααΆ (Control-panel) αα·αα’ααααα·ααα α’αΆαααα·αααΆαααΎα αααααααΌαααΆαααααααααα ααα αΆαααΆαααααααααΌαα»α (Modular), αααΆαααΆαα» DIN rail, αα·ααααααααα Busbar αααααΆααααααΆαααααααΆα§ααααΆα ααααα.
ααα’αααα»ααααααΆααα ααααΆαααααααΆαααΆαααΈα, ααΆαα ααα αΆαααΆαααααΎ DIN rail, ααΌαααααΆ, αα·αααααΏααααααΆααααααΆαααααααΆαααααααααΆααααααααΆα ULα.
α’αααΈαααααααΌααααααααααΆααα ααΆαα α»ααααααΈ UL, αααααααΆαααΆαααΆαααααααααααΆααα (Finger-safe covers), α ααααααααααΆα, ααΆαααααΎααααΆαααα½αααααΆααΆαα½αα’αΆααΆααααα, ααα αααααα αααα, αα·αααΆαααααααααΆαα½αα§αααααααΆααα αααα (Breaker) α¬ααααααααΆααα ααα»ααααΈα (Fuse holder)α.
10. VIOX Electric
VIOX Electric ααΊααΆαααααΎαααααΆααααααααααααΆααα’ααααα·αααααααα»ααααααααααααααααααααααα ααΆαααΆα (Busbars) αααααΆαα MCB, ααΆαααΆααααααααααα»α (pin-type) ααΆαααΆααααααααα (fork-type), α§ααααααααααααααααΈααααΆαααΌα , ααααΏααααααΆααα ααα αΆαααΆαααα’αααα·αααΈααααααα»αααΆα αα·ααααΆαααΆαα»αααααΆααα§αααααααΆααααααΎα (Circuit breaker)α αααααΊααΆααααααα½αααααα»αααΈαααααααα Busbar trunking ααααΆαααα VIOX ααΆαααΆαααα αααααααα»ααα ααααααα’αααα ααα αΆα αα·αα’αααααα‘αΎαααααΆαααααααΆ (Panel builders) ααααΌαααΆαααααΏααααααΆααααααααα»αααΆααααααΆαααΆααααααα αα·αα’αΆα ααααΎααααΆααααΆαα αααΎααα ααΆααΆαααααααααααααΆαααααααΆα’αααα·αααΈααΆααααΌαα.
ααα’αααα»ααααααΆααα ααΌα ααα αΆαααααΎα MCB, ααΆαααΆααααααααα·αααα (Comb busbars), ααΆαααΆααααααααααα»α/αα, ααααΏααααααΆααααααΆαααααααΆααααααα»αααΆα, ααΆααααααααααααααααααααααααααααΆααα’αααα ααα αΆα αα·αααΆααααααααααα OEMα.
α’αααΈαααααααΌααααααααααΆααα α ααα½ααααΌα (Pole count), αααααΆαααααα (Tooth pitch), αααααΆααα αα αΆαα’αααα·αααΈ, ααΆααααααααα α, α ααααα’αααα·αααΈαααααΆαααααα (Rated current), α’ααΈααΌα‘αα, ααΆαααα ααα αα αα·αααΆαααααααΆααΆαα½αααΉαααΆααα ααΆααααΆααΈα MCB ααααα α.
αααααΆααααΆαααΆααααααααα·ααα ααΌαααΎααααα VIOX αααααααα·αααααΆαααΆα MCB αα·α αααααααα·ααα MCB. αααααΆααααΆαααααΎαααΎααα αα αααααααΆααααααα ααΌαααΎαααΆαααααΆααααα VIOX ααααΈααΈ α§ααααααααααααααααΈ busbars, ααΆαααΆααααααααααα»α (pin type) αααααΉαααΆαααΆααααααααα (fork type), αα·α ααΆαααααΎαααΎαα§αααααα’ααΈααΌα‘αααααααΆααααΆαααΆα.
ααΆαααΆααααααΆααα§αααααααΆααααααααΈ (Circuit Breaker Busbar) αααααΉαααααααααααΆαααΆα (Busbar Trunking) αααααΉαααΆαααΆααααααΆαα (Laminated Busbar)

α’ααααα·αααΆα αααΎααααααααααΆαααααΆ βαααα»αα αα»αααα·αααΆαααΆαβ ααα»αααααα½αααααααΌαααΆαααα·ααααα»ααααααΆα ααΆαααααΆααααααα·ααα½αααααΌαααΆαααααΎααααΆααα ααα‘αααααΆα‘αΎαα.
| αααααααααΆαααααΆαα (Busbar Type) | α’ααααααααααααΆ | αα·ααΈααααααΆ | ααααααα’αααααααααααααααΌαα |
|---|---|---|---|
| ααΆαααΆααααααααα·αααααααααΆαα MCB | αααΆαααααΆαααααααα Pin α¬ Fork αααααΆαααααααΆααα§αααααααΆααααααΎαααααααααααααα· (MCB) | ααΌααααΎαααααΎααααΆαααααα»ααααα ααΌα ααα αΆαααααΎα αα·αααΌααααΎαααααΆαααΌα | α’αααααα·αααααΏααααααΆααα’αααα·αααΈααααααα»αααΆα |
| αααΆαααααΆαααααααΆααα§αααααααΆααααααΎα (Circuit breaker busbar) | αααΆαααααΆαααααααΆαααααααΆααα§αααααααΆααααααΎααα ααΆααααα»αααΌααααΎα α¬αααα’ααα ααα αΆαααααΎα | ααΌα ααα αΆαααααΎα (Panelboards) αααα’ααα ααα αΆαααααΎα (Load centers) αα·αααΌααααΆαααααααΆααααΎα (Switchboards) | α’αααααα·αα§αααααααΆααααααΎα αα·αααΌααααΎα |
| αααααααααααΆαααααΆαααααααΌαααΆαααα’αααα·αααΈ (Busbar trunking / busway) | ααααααααα ααα αΆαααααΎααααααααΎαααΆαααααΆααααΆααααααααΆαααΆα | α’ααΆα αααα ααα αα·αααααααααααα·αααααα | αααα»αα αα»αααα·αααααααααα ααα αΆαα’αααα·αααΈααααΆααα |
| ααΆαααααααααααα (Laminated busbar) | ααΆαααα‘αΎαααΆαααααααα’ααΈααΌα‘ααααΆαααααΆααα | ααΆαααααα’αααα·αααΈ (EV) α’αΆαα»α α’ααΈαααΊαααα αα·αααααΏαα’αα‘α·α ααααΌαα·αααΆααα | α’αααα―ααααααααααααααΆαααα·ααααααα |
| ααΆαααααααααΆααααααΌαααΆα | ααΆααααααα α¬α’αΆαα»αααΈαααΌααααααΆαααα ααααα½α | ααα·ααααΆαααααΌαα ααααα’αααα·αααΈ (Switchgear), ααααααααα’αΆαα»α, αα·αα§ααααα OEM | α’αααααααΆααααααααα·αααα α α¬αααΆαααααΆαα (Busbar) |
ααααα·αααΎααααααααααα’αααααΊααΆααΌα’αααα·αααΈ MCB α’ααααααα ααααΆααααΌαααΆααααα»αα αα»αααα·ααααΆαααααΆαααααααα Pin α¬ Forkα ααααα·αααΎααααααααααα’αααααΊααΆαααααααααααααΌαααΆααααααα»ααααα ααα α’ααααααα ααααΆααααΌαααΆααααααααα Busbar Trunkingα ααααα·αααΎααααααααααα’αααααΊααΆα§ααααααααααααααΆαααααααααα’αααα·αααΈ (EV inverter) α¬αααα ααα’αΆαα»α α’ααααααα ααααΆααααΌαααΆααα·ααααααααααΆαααααΆαααααααα Laminatedα.
ααΎα’αααΈαααααααΎα±αααααΆαααααΆαααααααΆααα§αααααααΆααα αααα (Circuit Breaker Busbar) ααΆαααΆαααΏααΆαα?
αααΆαααααΆαααααααΆααα§αααααααΆααα ααααααΉαααΌα ααΆααα αααααααααααΆα’αααα·αααΈ ααααΆαα·α αα·αααααα ααααΌαααΆαα αΆαααα»αααΆαααααΆααΈααΈαα αααΆαααααΆαααααααΆαααΆαααΏααΆααααααΌααααααααΆααΆααααααααΆαααααΆαααα (Contact resistance) α±αααα ααΆααααα»αααααααααΌαα.
| αααααΆ | α ααα»α’αααΈααΆαααΆααΆααααΆαα |
|---|---|
| ααααα·ααα»αααΆαααααΆαα α¬α’αΆαα»αααΈαααΌα | ααααΆαααααααΆαα ααααα’αααα·αααΈαααααααΌα ααΆ T2 / C11000 ααααΌαααΆααααααααΆααΌαα αα αααααααααααΆααααααααΆαααΆα αα·αααΆαααΎαα‘αΎαααααα αααααααααααα·αααΆαααΆαααΆααααααΆαα |
| ααααααΆαααααΉα (Cross-sectional area) | ααα₯αααα·ααααααααααααΆαα ααααα’αααα·αααΈ αα·αααΆαααΎαα‘αΎαααααα |
| ααΆαααααααααααααααΆα αΆαα ααΈααα α¬ααααΆαα | αα½ααααααΎαααΆααααααΉαααΆαα αααα αα·ααααα·αααΆαααααΆααααααΆαα; ααΆαααααααααααααααΆα αΆααααΆααΌαα ααααΌαααΆαααααααααα»αα αααααααΈ α£-α₯ ααΈααααΌαααααα ααα»αααααααααΆααα α»ααααααααΊα’αΆαααααααΎαααααΌαααΆααααααααα |
| αααααΆαααααα | ααααΌαααααααΌααααααΉααααααΆαααα ααα»α αααααΆααααααα§αααααααΆααααααΎα (Breaker) |
| αααααααααα»α α¬αααααααα | ααααΌαααααααΌααααααΉαααααααα ααα»α αααααΆαααααα MCB |
| αααααΆααα’ααΈααΌα‘αα | ααα₯αααα·αααααααΆααααααΉαααααα αα»ααααα·ααΆαααααΆαααα αα·αααΆααααααΉαα’ααααΆαααααΎα |
| ααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit) | ααααΆαααααα»αα’αα‘α»ααααααΆαααααΆαααΆαααΌα ααΆα |
| αααααΆαααααΆαααααα | ααΆααααααααΆαα·αααα’αααααΆαα±ααααΆαααααα αα·αααααΆααααΎαα’αααα·αααΈ |
| α ααααΆαααΌα (Creepage) αα·αα ααααΆααα»ααααα·ααΆα (Clearance) | ααΆαααΆααααααΆαααααααΆαααα»ααααα·ααΆααα·αααΆαα’αα»αααααΆααααααααΆα |
| ααΆαααΆααααααΆααααααΆαα·αααΆαααα ααα αα | ααΆαααααααααα α»ααααα»αααΆαααα‘αΎααα αααα»αααααααααα ααα αΆαα’αααα·αααΈ |
αααααΆαααααΆαααααΆαα (Busbars) αααα MCB α ααααΆααααΆααααααα (Pitch) αα·αααααααααα ααα»α αααααΆαα (Terminal geometry) ααΆααΏααααΆαααΆααααααΆααααΆαα’αααΈαααα’ααααα·αααααΉααα»αα αααΆαααααΆααααα βααααΎαααα’αΆα ααααΎααΆαα½αααααΆααΆαβ α’αΆα αααααΎααααααΆαααααΆαααααα·αααααΎααααΆ ααααα αα·αααααα·ααααα·ααΆαααααα·αα’αΆα αα»αα α·αααααΆαα.
αααΆαααΆαααααααα·αααααααααααα½αααααΆααα½α
αα·ααααααααΆαααααααααΊααΆα ααα»α ααααααα αααααΆαα’ααααααααααααααααΆαααααΆαααααααΆαααααΆααα·ααααΆααΈαα αα·αα’ααααααααααααΌαα α αααααΆααααααααααααΆαααααααΆ (Panel) ααΆααααΌαααΆα ααΌαααΆααα½ααααααααααΌα ααΆα
| αααΆαααΆαααααα | α ααα»α αααααΆααααααα |
|---|---|
| ααααα·αααααΆαα | ααααΆαααααααα T2 / C11000 α¬ααααΆαααααααΆαα ααααα’αααα·αααΈαααααααααααααααΆ αααααΆααΌαα ααααΌαααΆααααααααΆααΆαααΆαααα·αα»αααααΎαααΈ 99.9% |
| ααααα | ααΆααααααααα (Tin plating) ααΆααααααααΈααα (Nickel plating) α¬ααΆααααααααααΆαα (Silver plating) α’αΆαααααααΎααα·ααααΆα αα·ααααααΌαααΆαααααΆααααααΆαα |
| αααααΆαααααααααααΆ | ααΆααΌαα ααΆααααααΆαα 3-5 ααΈααααΌαααααα αααααΆααααΆαααΆαααΆαααααΆαααααααααΆαααααΆαα (Busbar) ααααααα»αααΆαααΌαα ; ααΌααααααααααΆααααΆαα½ααααααΉααα·αααααααα αα ααααα |
| ααααα·ααααααΉαα’ααααΆαααααΎαααα’ααΈααΌα‘αα | UL94 V-0 ααΊααΆααααα·ααααααααΌαααΆαααααΎαα»αααΆααΌαα αααααΆαααααααα’ααΈααΌα‘ααααααΆαααα·αααααααααΉαα’ααααΆαααααΎα |
| αααααααΆαααααααααΉαααααααααΎαααααα (Glow-wire performance) | ααΆαααΆααααααΆαααααααΆααααΌα’αααα·αααΈααΆααααααααΆα IEC αα·αααααΏααααααΆαααααααΆααααΌα ααα αΆαααΆααααααα»ααααα |
| ααΆαααΎαα‘αΎαααααΈαα»ααα ααΆα | ααααΌααααααααααααΆαααααααααααααααααα ααααα’αααα·αααΈαααααΆαααααα ααΈαα»ααα ααΆααααα»αααΌ ααΆααααα αααΆαααα»α αα·αααααααααααααΆαααα‘αΎα |
| ααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit) | ααααΌαααααααααΉαα ααααααααααΆααααα α»α (Prospective fault current) αααααααααα’αααα·αααΈ αα·αααΆααααααααααα½αααα§αααααααΆαααΆα |
| α ααααΆαααΌα (Creepage) αα·αα ααααΆααα»ααααα·ααΆα (Clearance) | ααααΌαααααααααΉαααα»α ααααα·αααααΆααααα»α αα·ααααααααααααααααΆααααααΆααααααα |
αα»αα αΆαααα»ααααααΆαααααααΆααααααααααααΆαα’αα»αααααΆαααα αααααααα·αα·α ααααααααΆαααα½αααα α»ααααααααΊα’αΆαααααααΎαααααααΆαααα·ααα ααΆααα ααΆαααααα’αααα·αααΈ ααΈαα»ααα ααΆααααα»αααΌ α§αααααααΆαααΆα αα·αααΈαα·αα·ααΈααααΆααααααΆαααα»αααΆαααΆαααααα.
αα»αααΆααααΆαααααΆαα (Busbar) αααα»αααΌα’αααα·αααΈα α’αααΈαααα’ααααα·ααα½ααα·αα·ααα
ααΆαααΏααΆααααααΌα’αααα·αααΈααΊα’αΆααααααααΆαααααΆαααα ααΎα ααα»α αααααΆαααααΆαα§αααααααΆααααααΎα (Breaker) αα·ααααΆαααααΆαα (Busbar)α αα αααα’ααααα·αααααΎααΆααααααααααααΆα α¬αααΌαααααααΌα’αααα·αααΈ αααααααααααΆαααααΆαααα½αααααΆααααααα½αααααΆαααΆαααααα αα·ααααααΆα’αααΈαααααααΌααα·αααααα αααααααααααααα.
αα αααααΆαααααααα»αααΆααααΆαααααΆαα (Busbar) ααααΌααααΎα ααΌααα·αα·αααααΎα
- ααΆαααααΆααααααΆααα§αααααααΆααααααΎα (Breaker) αα·ααααααΆαααααΆαααααα
- ααΆαααααααααααααΆαααααΆαα αα·αααΆααααααΉαααΆαα αααα
- αααααααΆαααααΆααααααααα αααααααααα»αα’αααα·αααΈαααα
- αααααΈα§αααααααΆααααααΎααααααααΌαααΆαα’αα»αααααααααα»αα αα»αααα·α
- α αααΆααααααΆααα ααααααααααΆααααααααΈααααΈ
- ααΆαααΆααααα½ααααα»αααΆααααα·αα§αααααααΆααααααΎααααα½α
- ααΆααααα ααααΆαααααα’ααααΆααααΉα (Neutral) αα·αααααααΈ (Ground)
- αα»αααΆαααααΆααα·αααααΆααααααΆααΎααΌααααΎα αα·ααααααΈααΆααααααααααααΈα’αααα·αααΈ
- ααΆαααααααΆααΆαα½αα§αααααααΆααα αααα AFCI, GFCI α¬α§αααααααΆααα αααααα»αααΆαααΈα
α ααα»α ααααααα·ααααααααααααα·ααα ααΎααα ααααα Busbar αααααα ααΆα’αΆα ααΆααααΆααααααααααααΈα (spring contact), αααα»αααααα§αααααααΆααα αααα (breaker stab), ααΆααααααααα α, αααααΆααααααα·α (torque), ααΆαααααααΆααααα§αααααααΆααα αααα α¬ααΆαααΎαα‘αΎαααααα αα ααΆααααα»αααΌααααΎααααααΆαα§ααααααααααΆααααΆααααΆααα.
αααααΈαααα½ααα·αα·ααααααααΆααααΆαααααΎαααΎα MCB Busbar

ααααΎαααααΈαααα½ααα·αα·αααααααα ααααα·α MCB Busbar αααααΆααααΌα ααα αΆαααααΎα α¬ααΌα’αααα·αααΈααααααΌαα»αα.
| ααΆαα»αααααααΌααα·αα·ααα | α’αααΈαααααααΌααααααΆαα |
|---|---|
| αααααα Busbar | ααΆααα ααΆααααΆααΈααααααααααα»α, αααααααα α¬αααααααα·ααα |
| α ααα½ααααΌα | 1P, 2P, 3P, 4P, 1P+N, 3P+N |
| ααΆααααα αααααΆααααΆα (Phase arrangement) | ααΆααααα αααααΆααααΆααααα½α (Single-phase), ααΈααααΆααααΆα (Three-phase) αα·αααααα’ααααΆααααΉα (Neutral) |
| αααααΆαααααα | ααΆααΌαα ααΆααααααΆααααΌαα»α α‘α¨ ααΈααΈαααααα ααα»ααααααααΌααααααααααΆααααΆαα½ααααααΈα§αααααααΆααααααΎα (Breaker) |
| ααΆαααααααα αα α»αααααα | ααααΌαααααΌααααααΆαα½αααΆααα ααΆαααααα ααα αΆαααααΎα αα·αααΆαααΆααααααααααααααΆααααα»α (Derating) |
| α’ααΈααΌα‘αα | αααααΉαα’ααααΆαααααΎα αα»ααααα·ααΆαααααααααΆαα ααααα·αααΈαα»ααα ααΆα αα·ααααααΌαααΆααααααααΆα UL94 V-0 α¬αααααααΆααααααΉαααααα (Glow-wire) ααΆαααΆαααααα |
| ααααααααΆαα | α’αΆα ααΆααααΆαααααα»ααααα·ααΆαααααα·αααααα±ααααΆαααααα»ααααα½α ααααααααααααααααΆαα |
| αααααα α»α (End caps) | αααααΌαα±ααααΆααααααΆααααΆαααΆαααΆααααααΆαααααααααΆαα |
| ααΆαααααααΆααΆαα½α MCB | ααΆααα ααΆα ααα»α αααααΆαα (Terminal) ααααΌαααααααΌααααααΆαα½αααααααα§αααααααΆααααααΎα (Breaker family) |
| α―αααΆααααααΆαααα»αααΆα | αααααΌααααααΆααααααααααααΆαααααααΆ α¬ααααααα ααα αΆαα’αααα·αααΈααΆααααΌαααΆα |
αααααΆααααααααΆααααα’α·αα’αααΈααΆαααααααΆ ααΌαααΎα Busbar αααααααααα»α αααααΉα Busbar αααααααα.
αααααΆαααααΆαααΌαα αα αααααααΎαααΎαα’ααααααααααααααααΆαααααΆαα (Busbar)
αααααΆαα’ααααααααααααααααα
- αα·αα’αΆα αααααΆααααΈααααα·ααα»αααΆαααααΆαα α¬ααααααααααΆααααααααα α
- αααααααααα·αα ααααα’αααα·αααΈααααα·αααΆαααΆααααααΆααααΈααααα·αααΎαα‘αΎαααααΈαα»ααα ααΆα
- αα·αα’αΆα αααααΆααααΈαααααΆαααααα (Tooth pitch) αα·αααΆαααααααΆααΆαα½αα§αααααααΆααααααΎα (Breaker)
- αα·ααααααααααααΆααααα’α·αα’αααΈα’ααΈααΌα‘αα α¬αααααα α»α (end-cap)
- αα·αα’αΆα αααααααααΌααα αα ααααα α¬αααααΉααα·αααααα (datasheets)
- α αΆαααα»ααααΆαααααΆαααααααα Pin αα·α Fork ααΆα’αΆα ααααΎαααα½αααααΆααΆα
- αα·αααΆαααΆααααααααααααΆαααα ααα αααααααΆααααΆαα ααα αΆαααΆαα αα
- αα·αα’αΆα ααΆααΆαα»αααΆαααα·αααα±ααααΆαααΆααααΈαααααΆααααααΆαααα»ααααααααΆα αααα·α
- α’αα’αΆαααΆα’αΆα ααααΎααααΆααααΆαααΆαα½αα§αααααααΆααααααΎα (Circuit Breaker) ααααααααααα
α αααααααΆαααααΆαααααααΆααα§αααααααΆααααααΎα ααΆαααααΆ βUniversalβ (ααααΎααΆαααααααααααα) ααΆααΏααααΊααΆαααααΆαααααΆαα ααΌαααΆαααα ααα»α αααααΆααααααα§αααααααΆααααααΎαααΆαααΆααα»αααααΆαα ααΆααααΆα αα·ααααααΈα α’αααααααααααααααααα’αα½ααααα½αα’αααααΆ ααΎα’ααααααα»αααααΎααααΆααα§αααααααΆααααααΎααααΆαα’αααΈ α ααα½αααα»ααααΆααααΌα (pole) α ααααααααααΆα (pitch) ααα»ααααΆα ααααα·αα ααααααα»ααααΆα αα·αααΆααα ααΆααΌααααΎααααααΆα.
αααΆαα§αααααααΆααααααΎα αααααΉα α’αααααα·ααααΆαααααΆαα (Busbar)
α’αααααα·αα§αααααααΆααααααΎα (Circuit breaker) αα·αα’αααααα·ααααΆαααααΆαα (Busbar) ααΆααΏααααΆαααΆααααα½ααααΈααααΆ ααα»αααααααααααααααΆαααααααααα·αααΌα ααααΆααα αααα»αα αα»ααα½αα’αΆα ααα·αα§αααααααΆααααααΎαααΆααααΆαααα’ ααα»ααααα’αΆα αα·αααααΏααααααΆαααααΆαααααΆαααα½αα ααα½αααΈα’αααααααααααααααααααααα αααα»αα αα»ααα½ααααα’αΆα ααΆαααααΆαααΆααααΆαααααΆαααααααΆαα MCB, αααΆαααααΆαααααααααααααΆαα (Laminated busbars) α¬αααααααααααααΌαααΆαααααΆααααΆαααααΆαα (Busbar trunking) ααααα·αα αΆαααΆα αααΆαααΆαααΈα αα§αααααααΆααααααΎααααααααα.
ααααα·αααΎα’αΆαα·ααΆαααααα’αααααΊααΆααααααααααααΆαααΈα αα§αααααααΆααααααΎα ααΌαααααΎααααα»αααααααα’αααααα·αα§αααααααΆααααααΎααααααΆααααααααΌα ααΆ VIOX ααΆααΎαα α’αααααα·αα§αααααααΆααααααΎαααΆααα»ααααα αααα»αααααααα α·α. ααααα·αααΎα’αΆαα·ααΆαααααα’αααααΊααΆαααΎαα‘αΎαααααα , ααΆαααΏααΆααααααΆααααααΆαα, ααΆαααααΎααααΆααααΆαααΆαα½ααααΆαααααΆαααααααααα·α (Comb busbar) α¬αα»αααΆααααααΆαααααΆαααααα»αααΌααααΎα (Load center busbar) ααΌααααααααΎα’ααααααααααααααααΆαααααΆαα αα·αααΆααα ααΆαααααααααααΆαααααΆααα.
αααα½ααααα½αααΉαααΆαα
ααΎααααΆααααααΆα’αααααα·ααααΆαααααΆααααΆααα»ααα?
α’αααααα·ααααΆαααααΆααααΆααα»ααααα½αααΆααααα»αα αα»αα ααα αΆαα’αααα·αααΈαααααΌα ααΆ Schneider Electric, Siemens, ABB, Eaton αα·α Legrand ααααΌα ααΆα’ααααααααααααααααΆαααααΆααα―ααααααΌα ααΆ Mersen, Rogers, EAE, Altech αα·α VIOX Electric αααααΆααααααααααααα·ααΈααααααααααΆα.
ααΎα’αααΈααΆααΆααα»αααααΆαααΆαα’αααααα·ααααΆαααααΆαα αα·αα’αααααα·ααααααααααααΆαααααΆαα?
α’αααααα·ααααΆαααααΆααα’αΆα ααα·ααααΆαααααΆαααα»ααα, αααΆαααααΆαααααααααα·ααααααΆαα MCB, αααΆαααααΆαααααααααααααΆαα α¬αααΆαααααΆααααΆααααααΌαααΆαα α’αααααα·ααααααααααααΆαααααΆααααΆααααααΆααααααααααααααααααα ααα αΆααααααα ααΌα ααΆαααααααααααααΌαααΆαααααΆααααΆαααααΆαα (Busbar trunking), αααααααα Busway, α§αααααααααΆαα (Adapters), αααααα (Holders), α§ααααααααααααααΎα (Tap-off units) αα·αααααΏααααααΆαααααααΆααααα‘αΎαα.
ααΎα’αααΈαααααααΎα±αααααΆαααααΆαα (Busbar) αααααΆααα§αααααααΆααααααΎα (Circuit Breaker) ααΆααα»αααΆαααα’?
αααΆαααααΆαααααααΆααα§αααααααΆααααααΎααααααΆααα»αααΆαααα’ ααααΌαααααΆααααααΆααααααΉαααααΌα ααΆααααααααααααααΉαααααΌα ααααα·αα ααααα’αααα·αααΈαααααα α ααααααααααααααΉαααααΌα ααΆαααΆαααΆαα ααααα’αααα·αααΈ (Insulation) ααΆαααααΆααααααΆαααΆααα·ααααα·αααααΆαα½αα§αααααααΆααααααΎα αα·αααΆααααααααΆαααααααααΉαα αααααααα (Short-circuit)α αααααααααααΆαααΆααααΆαααααΆαααα·αα§αααααααααΌαααααΆααααα·αααΆα αααααΈαααα·ααααααααααα»αα αααα αα·αααΆααααααααα½αααΈαα»ααα ααΆααααααα.
ααΎαααΆαααααΆαααααααααααα»α (Pin type) αα·ααααααααα (Fork type) α’αΆα ααααΎαααα½αααααΆααΆααααα¬αα?
αα·αα’αΆα ααα αααΆαααααΆαααααααααααα»α αα·ααααααααα ααααΌαααΆααα ααΆα‘αΎααααααΆααα§αααααααΆααααααΎααααααΆααααααααα»ααααααΆα ααΆαααααΎααααΆαααα»αααααααα’αΆα αααααΆαα±ααααΆααααααΆαααα·αΰΉΰΈΰΉΰΈ ααΎαααααα ααααΆαα α¬ααΆααααααααΆαα·αααΆααα»ααααα·ααΆαα ααααΌαααααααΎαααΎααααΆαααααΆααα±ααααααΌαααΉαααααααααα ααα»α αααααΆααααααα§αααααααΆααααααΎαααΆαα·α αα α.
ααΎαααΆαααααΆααααααααααΆαααααα’αααα»ααααααΆααααΌα’αααα·αααΈ MCB?
αααααΆααααΌα’αααα·αααΈ MCB αααΆαααααΆαααααααα’αααα»αααΆααΌαα ααΊαααΆαααααΆαααααααααα·αααα (Comb busbar) αααααΆααααααΆααααΆαααΆαααααΉαααααΌα ααΆαααααα·αα αααααααααα ααΆαααΆααααα αα ααα½ααααΌα (Pole) ααααΉαααααΌα ααΆαα ααααααααΌαα»αααααΉαααααΌα ααΆααααααααααα»αα¬ααααααΉαααααΌα αα·αααΆααααααα α»α (End caps)α ααΆαααααΎαααΎααααΆαααΈα ααα·αααΌαααααΆααααΆαααΆαααααααΆααααΉαααααΌα αα·αα―αααΆααα αα αααααααααααααΆααααΈαα»αααΆααααααα.
ααΎαααα»ααα½ααα·αα·αααααΎαα’αααΈααααααΎααααΈααΉαααΈαα»αααΆααααααΆαααααΆαααααα»αααΌα’αααα·αααΈ (Load center)?
ααααΌααα·αα·αααααΎαααΆααα ααΆα ααα»α αααααααΆαααΆαα§αααααααΆααααααΎααα·ααααΆαααααΆαα ααΆαααααααααα ααΆαααΎαα‘αΎαααααα ααΆαα α»ααααααΈαααααααΆαααααααΌα’αααα·αααΈ αααααΈα§αααααααΆααααααΎααααααααΌαααΆαα’αα»ααααΆαα±ααααααΎααααΆαα ααααα·αααααααααΉαα αααααααα (Short-circuit rating) αα·αααααααΆααααα»αααΆααααα·αα§αααααααΆααααααΎααααα½αα ααΆαααΏααΆαααααα»ααααααααααα’αΆαααααααΎα ααα»α αααααΆααααΆααααΌααααΆαα§αααααααΆααααααΎααα·ααααΆαααααΆαα αα·ααααα’αΆαααααααααΎααα ααααααααΆαααααΆαααααα½ααα»ααααααα.
ααΎ VIOX ααΆαααα»αα αα»αααα·ααααΆαααααΆαα (Busbar) αααα¬?
VIOX Electric ααααααααααααα·ααααααΆαααααΆααααααααα»αααΆα αα·αααααΏααααααΆααααΌααααΎα ααΆαα·ααααααΆαααααΆαααααααΆαα MCB, αααΆαααααΆαααααααα Pin αα·α Fork αα·αααααΏααααααΆαααααααΆααααααΆααα§αααααααΆααααααΎα (Circuit Breaker)α ααΆαααααα·αααααα»ααααααΆααα’αααα ααα αΆα, αααα»αα αα»αααα·αα§αααααααΎα (OEMs) αα·αα’αααααα‘αΎαααΌααααΎαααααααα»ααααααααααααΏααααααΆααααααααα»αααΆαααααααΌαα»αα.
ααα ααααΈααααα·
αααα»αα αα»αααα·ααααΆαααααΆααααααα’αααα»αααΊα’αΆαααααααΎαααααααααΆαααααΆαααααα’αααααααΌαααΆαα.
αααααΆααααΌααααΎαααα αα·ααααααααααααααΌαααΆααα (Busbar trunking) αααα»αα αα»αααα·αα§αααααα’αααα·αααΈααααΆαααα·αααααααΌα ααΆ Schneider Electric, Siemens, ABB, Eaton αα·α Legrand ααΊααΆαααααΎαααααΉαααΆαα αααααΆαααααΆαααααΆαααααααα Laminated αα·αααααΏαα’αα‘α·α ααααΌαα·αααΆααα αααα»αα αα»αααΌα ααΆ Mersen αα·α Rogers ααΊααΆαααΆαααΆαααααααααΆαα α αααααααΆαααααΆαααααααΆαα MCB, αααΆαααααΆαααααααα Comb αα·αααααΏααααααΆααααΌααααΎαααααααα»αααΆα VIOX αα·αα’αααααααααααααααααΏααααααΆααααΌααααΎαα―ααααααααααααα’αΆα ααΆαααααΎααααααΆαααααααααΆαα.
αα»ααα·ααααΆαααααΆαααααααα’ααααΎααααααααααΆαααΈα αα ααΌααα·αα·αααααΎαααΆαααααΎααααΆαα, ααΆαααααααΆααα§αααααααΆααααααΎα (Breaker), ααααα·αα ααααα’αααα·αααΈ, ααΆαααΎαα‘αΎαααααα , ααΆααααααααα α, ααΆαααΆαααΆαα’ααΈααΌα‘αα, αααααΌαααΆαααααααααΉαααΆαααααα ααααααααΈ (Short-circuit) αα·αα―αααΆααα αα ααααα αα»ααααααααΎαααΎαα’αααααααααααααα.