α ααααΎααα ααα ααΎα’αααααααΎαααΎαα§αααααααααααααααααΆ (Timer Relay) αααααααααΆ?
ααααΎαααΎα ααΈα‘αβαααααβαααα αααααα’ααααΎαααααΌαααΆαααΆαααααααα ααα½αααααΆαααΈαα αα»αααΆαααααααααααααΆ, ααα»ααααααααααα, ααααα·ααα·ααααααααααΆαααααα (Contact rating), αα½ααααααααΆ, ααΆααααα αααααΆαααααααααααα, ααααααααααΆαααα‘αΎα αα·αααααΆααΈαααααααααΎαα ααα α»ααααααααα»αααΊααΆαααααΎαααΎααααααα’ααααΎαααααααΆαααααΆααααα½ααα»α ααααα·ααα·αααΈααααααααααα»α (Load type), ααα»ααααααΆ αα·αααααα·ααα·ααααααααααΆααααααα.
ααααΎααααΆααααααααααα
- ααααΎαααΎααα»αααΆαααααααααααααΆα On-delay, Off-delay, Interval, Cyclic, Star-delta α¬αα»αααΆαα αααα»α (Multifunction)α.
- ααααΌααααααα»ααααααααααααα ααΉαααααααΈαααααΆα.
- αα·αα·αααααααα·ααα·ααααααααααΆαααααααααααΉαααααααααααα»αααΆααααααα αα·ααααααααΉαααααΎααααα’αααααααααΆααααα αΆααααααα.
- ααααΎαααΎααα½ααααααααΆααααααααααΌαααΆαααααααα½ααααααααααΆααααααα·αααΆαααααααΆαα αααΆααααΆαααααα»αααΆααααααα.
- ααααΎαααΎαααΆααααα αααααΆααααααααααααα SPDT, DPDT, NO/NC α¬ααααΆααααααα αααΎαα.
- αααααααααΆααααΆααΆαααα‘αΎα αα·αααααΆααΈαααααααααΎαααααΌαααααΆααΉαααΆααα ααΆααααααααΆαααααααΆ (Panel design)α.
- αααααααααΆααα―αααΆα αααααααΆα αα·αααΆαααΆααααααΈα’ααααααααααααα αα»ααααααααΎααΆαα’αα»αααα.
ααααα·αααΎα’αααααααΌαααΆααα·αααααα§αααααααΌαααααΆαααΆαα»α ααΌαααΎα ααΎα§ααααααααααΌααααααααααααΊααΆα’αααΈ?. ααααα·αααΎα’ααααααα»αααααααααααα·ααααα½α α αΎα ααΌαα αΌααα ααΆαα ααΆααααααΌαααααααα·ααΈααααααααα VIOX αααααααα·αααα.
αααααΈαααα½ααα·αα·ααααααααΆααααΆαααααΎαααΎαα§αααααααααααααααααΆ (Timer Relay)

| αααααΆααααΎαααΎα | α’αααΈαααααααΌααα·αα·ααα | ααα α»αααΌαα |
|---|---|---|
| αα»αααΆα | On-delay, off-delay, interval, cyclic, star-delta, multifunction | ααΆααα·αα§ααααααααααΌαα (Relay) αααααΆααα»αααΆααααα½α αα ααααααααααΌαααΆααα»αααΆαα αααΎα |
| ααα»ααααααααααα | 12 V, 24 V, 110 V, 230 V, AC/DC α¬ααΆααααα αΌαααΆαααααΆααα | ααΆαααααΌααααααα»ααααα»α (Load voltage) αααα½αα±ααααα»ααααααΆ (Control voltage) |
| ααΆαααΆααααααααααΆαααααα | AC-1, AC-15, DC-13, ααααα»ααααααααΆα (resistive) αααααΉα ααααα»αα’αΆαααα»α ααα (inductive) | ααΆαααααΎααααΆααααααα·αα αααααααααααΆααααααΆααα§ααααααα»αααΆααααα (contactor coils) α¬ααΌα‘αααΌα’ααΈα (solenoids) |
| αα½ααααααααΆ | αα·ααΆααΈ, ααΆααΈ, αααα, αα½ααααα’αΆα αααααααΌαααΆα, ααααα·αααΆαα αααΆααααααΆαααααα (setting resolution) | ααΆαααααΎαααΎααα½ααααααααααααααΆαα±ααααΆαααααααΆαααΆααααΆααααααΆαααααα |
| ααααΆαααααααα·ααααα | SPDT, DPDT, NO/NC, α ααα½ααααααααα (outputs) | αααααααααΆαααααα (contacts) αααααΆααααααααααα αΆααααα (interlock) α¬ααΆααααααΌααααααΆαααα‘αααααα·α (signal feedback) |
| ααΆααααα | αααααα DIN rail, ααααααα (socket), ααΆαααα‘αΎαααΎααααα (panel mount), ααΎαααα (plug-in base) | ααΆαααααΎαααΎααααα‘αααααα·αααααααααΉαααΌαααααΆ (control cabinet) |
| ααααΆααΈααααααΆααααααααααΎα | A1/A2, 15/16/18, ααΆαα»α αΌααααααΆααααα (trigger input), ααΆαα»α αΌααααααΆαααααααα‘αΎααα·α (reset input) | ααΆααααααΆααααααααααΎααα»ααα ααααΆααΈαααααααααααααΆααα, ααααΆααΈααααααΆ (trigger), αα·αααααΆααΈαααααΆαααααααααααα (output contact) |
| α―αααΆα | αααααΉααα·αααααααα αα ααααα, ααααΆααααΆααααααΆααααααααααΎα, ααΆααΆααααααααΆ, αααααααΆα | ααΆαααααΎαααΎααααααα’ααααΎααΌαααΆααααα»αααΆααΆα‘α»ααααα½αα±αααα·αααααααααΌαααααΆααααααα |
ααα αΆαααΈ 1α ααααΎαααΎααα»αααΆαααααα§αααααααααααααααααΆ (Timer)

αα»αααΆαααΊααΆααΆααααααα α α·αααααααΌαα α§αααααααααααααααααΆαα·ααααααααΆααααααΆ βα§ααααααααααΌααααααΆ (Relay) αααααΆαααααα·ααΆααΈαα ααΎαα»ααα»ααααβ αααααα ααααααααααααααααΆαααααΆαααααΎαααΎαααααΌααααααααα ααΉαα’αααΈαααααααααΈα’αααα·αααΈααααΌαα’αα»ααααα.
| αα»αααΆααααααααααααΈα‘α (Timer relay) | ααααααααΎαααΆαααααααΆ | ααΆαααααΎααααΆααααααααΆα |
|---|---|---|
| αααααΆαααααΎα | αααααα (Output) ααΉαααααΆααααααΌααααααααααααα αΌαααΆααα α¬αααααΆα αΌα α αΎααααααααΆαααααΆαααΆααα»αααααα | ααΆααααααΆααααα αΆααααααΎααααΌααα, ααΆαα αΆααααααΎαααΆαααααΆααααααα, ααΆααααααΆαααααααααΆα’αΆαααα |
| αααααΆααααα·α | αααααααα ααααααΎαααΆααααα»ααααααααααααΆαααααα αααααΆααααΈααΆαααΆαααα (Trigger) α¬ααααααααααααΆαααααααααααααΆαααααΆαααΆαααααΆααααααΌα | ααΆαααααΎαααΆααααααααααααα αΆα, ααΆααααααΆαααααααΌαααααΌαααΉα, ααΆααααα’αΆααααααα ααα αΌα |
| α αααααααα | ααααααααΉαααΎαααααΎαααΆααααα»αααααααααααααα½α αααααΆααααΈααΆαααΆαααα (Trigger) | αααααΆααΈαα αααΆααααααααΆ, αααααααααααΆα’αΆαααα, αααααΆαααααΆα§αααααααααΈα |
| αααα / ααααααααα | αα·αααααααααΆααααααΆ ααΎα/αα·α ααΆαααααααααΆαα | αααααΆααααΉααααααα αααααααααΆαααΈαααΌα α¬ααΆααααα ααααΆαα·ααα’α·αααΆαααΆαααααα |
| α§αααααααααααααααααΆααααΆα-ααααΈααα (Star-delta timer) | αααααααααααΆαααααΌαααΈααΆααααααΆααααααΆααα ααααΈααααα αααα»αα§αααααα αΆααααααΎααααΌααα | ααΆαα αΆααααααΎααααΌααααααααααΎααα»αααΆα |
| α§αααααααααααααααααΆαα α»αα»αααΆα | ααααααααααααααααΆααΆα αααΎααααα’αΆα ααααΎαααΎαααΆααααα»αα§ααααααααα½α | αααααα’αααα·αααΈ OEM, ααΆαααΆαααααααααααΏααααααΆαα, ααΆαααΆααα±ααααααΎαααΆαααααααααααΆααααααα |
ααααα·αααΎαααααα’αααα·αααΈααααΌαααΆααααα»αααΆαααααα½α α αΎαα αΆαα·αααααααΆαααααααα ααΆαααααααααα»αααααΌαααααΆαααααα·αααΆα αααα§αααααααααααααααααΆ (Timer relay) αααααΆααα»αααΆααααα½αα’αΆα ααΆαααααΎαααααα’αααααΎαα ααααα·αααΎα’αααααα‘αΎααααααα’αααα·αααΈα ααααααΎ SKU αααα½ααααααΆααααααααααααααααααΆααΆα αααΎα αααα§αααααααααααααααααΆαααααΆααα»αααΆαα αααΎαα’αΆα ααΆαααΆαααΆαααααααααΆαα αααααΆααααΆααααααα α α·αααααα ααΌαααΎα αααα‘αααααααααααααΆαα α»αα»αααΆα αααααΉα αααα‘αααααααααααααΆαααααΆααα»αααΆααααα½α.
ααα αΆαααΈ 2α ααααΌααααααα»ααααααααααα (Supply Voltage)
ααα»ααααααααααα ααΊααΆααα»αααααααααααΆααααααααααΏαα’αα‘α·α ααααΌαα·α α¬α§ααααα (coil) ααααα§αααααααααααααααααΆα ααΆαα·ααααααΆααα»αααΌα ααααΆαααααααΌαααΆαααααΌααααααααΆαααααααα·ααααα (output contact) αααααααααααααααα·αααααα.
ααααααααα»αααααααααααααΌαα αααααΆααα§αααααααααααααααααΆαα½αααΆαα
- 12 VDC
- 24 VAC/DC
- 110-120 VAC
- 220-240 VAC
- ααΆαα»α αΌα AC/DC αα½αααααΌααΆα α¬ααΆααα
ααα α»ααααααααα»αααΆααααααΆααααααααααΎααααααααααα½αααααα ααΊααΆαααααΎαααΎαα§ααααααααααΌααααααΆ (Relay) αααααα’ααααΎααααα»α 230 VAC αααααΈααΆααααααΈαααααΆαααα»αααΌααααΎαααΆαααααα·α 24 VDC αααααα ααΆαααααααααααααΆααααααα§αααααααααααααααααΆ (Timer relay) ααααΌαααααααΌααααααΉαααααααΈαααααΆααααααααΆαααα ααΉαααααΆααΈαααααααααααααΆαααααααααΆα.
α§ααΆα αααα α§αααααααααααααααααΆαααααα 24 VDC α’αΆα ααααΎ A1/A2 αααααΆααααΆαααααααααααααΆααα 24 VDC αααααααααααααΆαααααααααααα (Output contact) ααααααΆααααΌααα ααααααΈαααααΆ AC ααΆα ααααα‘αααα½αααα αααααΆαααααααααααΆααααΆαααααααααααααααααααΌαααααΆαααααα·ααααααααΆα (Rated) αααααΆααααααα»ααααα.
αααααΆααααΆαααααΎαααΎαααα»αα±ααααΆαααααααα’α·α ααΌαααΎα ααααα»αααααααααααΎαααΎαααα»α Timer Relay: 12V, 24V, 120V, 230V.
ααα αΆαααΈ 3α αα·αα·αααααααα·ααααααααΆαααααΆαααααα αα·αααααααααααα»α

ααααα·ααααααααΆαααααΆαααααα ααΊααΆα ααα»α αααααΆαααΌα ααΆαα§αααααααααααααααααΆααΆαα αααΎααααααα αΆααααααΎαα.
ααααΆαααααααα·ααααα (Output contact) ααΊααΆααααααααααααΎααΆαααΆαααα ααααααΆαααααααα αααααααΈα‘α (Timer relay) α’αΆα ααααααααααααΆααΆαααααΉαααααΌα ααα»αααααα ααα’αΆα ααΌα αα»αααΆαααααα ααααα·αααΎααααΆααααααααααααΆαα·αααααααααΉαααααα»α (Load)α.
αα·αα·αααα
- ααα»ααααααααααααΆαααααα (Rated voltage of the contact)
- α αααααααααααααααΆαααααα (Rated current of the contact)
- ααΆαααααα·α αα αααα»αααΆαααΆαααα ααααααααΆαα (AC) α¬α ααααααααΆαα (DC)
- ααααα»ααααααααααααααΆα (Resistive) α¬ααααα»αααααααα’αΆαααα»α ααα (Inductive load)
- ααααααααααΆαααααΎααααΆαα (Utilization category) ααΌα ααΆ AC-1, AC-15 α¬ DC-13 ααΆαααααΈαααα’αΆα α’αα»ααααααΆα
- ααΆααααα αααααΆαααααα (Contact arrangement) ααΌα ααΆ SPDT α¬ DPDT
- αα·ααααααα’αααΈααΆαααααααααααααΆαα·α αα·αα’αααα·αααΈαααααΆααααα»ααααααΉααα·αααααα (Datasheet)
αα»αααααΎααααα·αα’αααααααααΆααααααα»ααααααααααααααΆα (Resistive-load) ααα’αα»ααααααΆαα½ααααααααααααααααα»αααΆααα’ααα ααααΆαααααααααααααΌαααΆαααααααααααΆααα αααααααααααΎααααα»ααααααααααααααΆα α’αΆα ααΆαααααα·αααΆαααΆααααα αααΎααα αααααΆαααααααα»αααααααα’αΆαααα»α ααα (Inductive control load) ααΌα ααΆα§ααααααα»αααΆααααα (Contactor coil), ααΌααααΌα’ααΈα (Solenoid), αααΆαα (Valve) α¬ααααααΈαααα½ααααααααΌαααααΌα αα.
α§ααΆα ααα ααααΆαααααααααααααα‘α (Relay contact) αααααΆαααααα·αα αααααααα αα 10 A αα ααααααα»α 250 VAC αααααΆααααααα»ααααααα Resistive α’αΆα ααΆαααααα·αααααΉαααααΈαααΈα’ααααααα»ααααααααααΆααααααααααααα»α Inductive ααΌα ααΆ AC-15α ααααααα·αααααΆααααααΌαααααα’ααααΎαααααΉααα·αααααα (Datasheet) ααα»αααααααααΆαααααΊααΆααααα ααααΎαααΎαααΆαααααααααααα»α (Load category) αα·ααααααααΎαααΎαααΆααααα’αααααααααα»ααααααΆαααααα»ααααα ααΎαααα‘ααααααα.
ααααα·αααΎααΆαααΌα ααΆαααααΆααααααααΎααααα»α Inductive ααΊααΆααααααα ααααααααα’ααα ααΌαα’αΆα ααΌαα ααα»αααααααΆαααααααααααααα‘αααααααααααααΆ (Time Relay) ααΌα ααΆαααΎααααα»α Inductiveα ααΆαααΆαααααα AC-1 αααααΉα AC-15.
ααα αΆαααΈ 4α ααααΎαααΎααα½αααααααααααααΆ αα·αααΆαααΆααααΆααααααΆαααααα
αααα‘αααααααααααααΆ (Timer relay) αα½αααααααααααααααΎααΆααααααΆαααααααααααΌαααΆα ααα»αααααα·ααα½αααΆααα½αααααΌααΆαα α½αααΈαααααΌαααΆααααααα.
ααααα·αααΎαααααα·ααΈααααΌαααΆαααΆααααααΆαααα 3 αα·ααΆααΈ αααα‘ααααααΆααα½α 0.1-10 αα·ααΆααΈ ααΆααΌαα ααΆααααα½ααααααα±ααααΆαααααΉαααααΌαααΆααααα‘ααααααΆααα½αααΈ 0.1 αα·ααΆααΈ ααα 100 ααααα αα½αααααΌααΆαααααΆααα’αΆα ααΆααααααααα ααα»ααααααΆααα’αΆα ααΆαααααααααΆαααΆααααΆααααααΆααααααααΆααααααααα ααΎαααΌαα»αα α»α α’αΆααΆα‘αΌααααααα.
αα·αα·αααα
- αα½ααααααααΆα’αααααααΆ αα·αα’αα·ααααΆ
- ααΆαα’αΆαααΆαααααααΆα
- αα·ααΈααΆααααααααααα ααααΆααα α»α (dial), αα»αααΆαα DIP, αα»αααΆααααααα·α (rotary selector) α¬α’ααααααααΈααΈαα
- ααΆαααααΉαααααΌαααααΆαααααΎααααααα αα·αααΆαα’ααααααα (tolerance)
- α₯αα·ααΆααααααΆααααααα‘αΎααα·α (reset)
- α₯αα·ααΆαααααααααα‘ααααααΆααααΈααΆα αα ααααα’αααα·αααΈ
αααααΆααααΆαααααΆαααααααΆ αα·αααΆααααααα α α·αααααΎαα½ααααααααΆ ααΌαααΎα ααααααααΆαα½ααααααααΆαααααααα‘αααααααααααααΆ (Timer Relay).
ααα αΆαααΈ 5α ααααΎαααΎαααααααααααΆαααα‘αΎα αα·αα ααα»α αααααΆααααααααααΎα (Wiring Terminals)
Timer relays ααααΌαααΆαααααΎααααΆααααΆααΌαα αα αααα»αααααΆαααααααΆ (Control panels), ααααΆαααααααΆαααΌααα (Motor starter panels), ααΌ HVAC, ααααΆαααααααΆαααΆαααΈαααΌαααΉα αα·ααααα’αααααααΆαααΆαααΈαα ααααααααααΆααααααΎαααααΌααααααααααα ααΉαααΆααα ααΆααααααΆαααααααΆα.
ααααααααααΆααααααΎαααΌαα αα½αααΆαα
- Timer relay αααααααααααΎαααΎ DIN rail
- Timer relay ααααααααα (Plug-in) ααΆαα½αααααααα (Socket)
- Timer αααααααααααΎαααΎααααααααΆαααααααΆ (Panel-mount)
- αααΌαα»αααααααααααααΆαααααα PCB α¬αααααααααααα (Embedded)
αααααΆααααααΆαααααααΆα§ααααΆα αααα αααααα DIN rail αα·αααααααααα (Plug-in socket) ααΊααΆαααααααααααααΎααααΆααα αααΎαααΆαααα ααΆααααααΎαααΎ DIN rail ααΆαααα αααΌα αα·ααα½αα±ααα’αααααα‘αΎαααααΆαααααααΆααααΎααΆαααΆααααΆααα ααα ααααααααα (Plug-in socket) ααΆααααααααααααα»αααααΈαααααααΌαααΆαααΆαααααΆααααααΌαα§ααααααααΆααα ααα.
αααααΆαααααΆααααααΆααΈα (Terminal) ααΌαα

α§αααααααααααααααααΆααΆα αααΎαααααΎααααΆααααΆααααααα αααΆαααΎααααΆααΈαααΌα ααΆα
| ααααΆααΈα | α’ααααααααΌαα |
|---|---|
| A1 / A2 | ααααΆααΈαααααααααααααΆααα α¬ααααΆααΈααααααΆ |
| 15 | ααααΆααΈαααααΆαααααααα½α (Common contact terminal) |
| 16 | ααααΆααααααααααα·αααΆααααααΆ (Normally closed contact) |
| 18 | ααααΆαααααααααααΎαααΆααααααΆ (Normally open contact) |
| B1 / S / Trigger | ααΆαα»α αΌααααααΆααααα (Trigger) α¬ααΆαα»α αΌααααααΆααΈααΆααααα α’αΆααααααα ααΆααααΌααα |
| ααααα | ααΆαα»α αΌααααααΆαααααααα‘αΎααα·α (Reset input) α’αΆααααααα ααΆααα»αααΆα |
ααΆααααααΆααααΆαααααααΊααΆααΏαααααααΆ ααα»αααααα·ααααααΆαααααααΆααααααΆααααααααααΌααααααααα ααααΆααααΆαααααααααΎααααααααα»ααααα ααΎαα½α§ααααα α¬αααααΉααα·αααααααα αα ααααα ααΊααΆα―αααΆααααα α»αααααααααααααΉαααααΌααααα»αα.
αααααΆααααααααΆααααα’α·αα’αααΈααΆααααααΆααααααααααΎα ααΌαααααΎααααΆαα ααααα»αααααααααααΆααααΆαααααααααΎααααααΆαααα»αααΆααααααααααααααΆ (Time Delay Relay).
ααα αΆαααΈ 6α ααααΎαααΎαα§αααααα±ααααααΌαααΉαααΆαααααΎααααΆαα
ααααααααααΆαααΌααα (Motor starter panels)
αααααααΈα‘α (Timer relays) ααααΌαααΆαααααΎαααααΆααααΆαα αΆααααααΎαααααααααΆαααα ααΆααααααααααΆαααααΌααααααα½α ααΆααααααΆαααααααααΆααααΉαααΆαα αΆααααααΎαα‘αΎααα·α αα·αααΆαααααΌαααΈααααΆααα ααααΈααα (star-delta)α ααΆααΌαα αααααααΈα‘αααααΎααΆααα·αααΎαα§ααααααα»αααΆααααα (contactor coil) α¬ααααααΈαααααΆ αα·αααααα·αααΎαααααααΈααΆααααααΌααααααααααΆαααααααα.
ααααα·αααΎαααααααΈα‘αααααΌαααΆαααααΎααΆαα½αα§αααααα αΆααααααΎααααΌααα (motor starter) ααΌααα·αα·αααααΎαααα»αααααα§ααααααα»αααΆααααα ααααα·αααααΆαααααααααααΆαααα»αααΆα AC-15 αααααα·ααααΆααααΆααααααΆαααααα αα·αααααααααααΆααααααα‘αΎααα·α (reset)α.
ααΆαααααααααααααΌαααααΌαααΉα αα·ααααΆαααΈααααα αΆααααααα
αααΌαααααΌαααΉα αα·ααααΆαααΈααααα αΆααααααααααααααααΌαααΆααααααα·ααααΆαααααΆαααα ααΎααααΈααΆαααΆαααΆααα·αααΎαααΉαααΆααααα (short cycling) ααΆααααααααααααΆαααααΎαααΆααααα α¬ααΆααααααααααΆααααααααα»αα αααΎαα α ααα»α ααααΆααααααα»αααΆαααααΎαααΎαααΊ αα»αααΆααααααΆααααααααα·α/ααΎα (off-delay/on-delay) αα½ααααααααΆ ααααααααααΆαα αΆααααααΎαα‘αΎααα·ααααααΆααααΈααΆα αααααΎα αα·αααα·ααααΆααααααα’ααααΆαααΆαα.
αααααΆααααα·ααααααΆαααΆαααΆααααΌαααααΌαααΉα ααΌαααΎα ααααα»ααααααααααααααΈα‘ααααααΆααααΆαααΆαααΆααα·αααΎαααΉαααΆαααααααΌαααααΌαααΉα.
ααΆαααααααααααααααααα HVAC αα·ααααα αΆα
ααααααΈ HVAC α’αΆα ααααΎα§αααααααααααααααααΆ (Timer relays) αααααΆααααΆααααααΆαααααααΆαααΈααααα αΆαα (Compressor), ααΆαααααΎαααΆααααααααααααα αΆα, ααΆαααααααααααααΆαααα ααααααα, ααΆααααααΆααααααααααα·αααΎα (Damper) αα·αααΆαα αΆααααααΎαααααΎαααΆαααΆααααΆααααΆαα α§αααααααααααααααααΆαααααΆαααααΎαααΎαααααΌαααααααΌαααααΆααΉαααααααα»ααααααΆ α αΎααα·ααα½αααααΎαααΎααααααα’ααααΎαα½ααααααααΆαααααΆααααα½ααα»ααααααα.
αααααΆααααΆαααααααααααααΆααΆααααΆαααααααΆαααααΆαααΈααααα αΆαα ααΌαααΎα ααΆαααΆαααΆααααΆαααΈααααα αΆαααααα§αααααααααααααααααΆαααααΆααααααΆαα HVAC.
ααααααΈααααΎαααααααΊ αα·ααααααΆαααααΆα
α§αααααααααααααααααΆα’αΆα αααααααΌαααΆααααααΆααααααααΎαααααααΊ, ααΆααααα αααααααΊααααΉααααααα, ααΆαααααααααααααΆαααααΎα, ααΆααααααΆαααααααααΆ α¬αααααααααααΆαααααΆαα ααααα·αααΎαα·α αα ααΆααααααα’ααααΎααΆαααααααααααααΆαααα αΆααααα/αααα αΆααααααΆα α ααΆααΆαααΆαααααααααααααΆααΆαααααΆαααααααααααΆαααααααααα αααα§αααααααααααααααααΆαααααα Timer switch α’αΆα ααΆαααααΎααααααααΎαααΆαα.
ααΆαααααααααααααα·αααααααΆαααΈαααΆαααα
αααααΆαααα»αααΆαααααααααααααΆαααα»αααΌαααααΆααααα½α α§αααααααααααααααααΆα’αΆα ααΆαααΆαααΆααααα½αααΆαααΆααααααααΌααααααα·ααααΆ PLCα α ααααααΆααααααααααΆααααααααααααΆαααΈααααααΆαααΆαα»α αΌαα αααΎα, ααΆαααααΆαααααααααααα»ααααα·ααΆα (Interlocks), ααΆαααΌαααααΉα, ααΆααααααααΆαα·αααααα α¬ααΆαααααααααααααΆαααα’αΆα ααααααα½αααΆαααΆαααα HMI ααΆαααααΎααααΆαααααααα·ααααΆ PLC ααΊααααααααααΎαααΆαα.
α ααααααΆααααααα α α·αααααΎααααΆααααααααααα ααΌαααΎα αααα‘αααααααααααααΆ αααααΉα αααααα·ααΈααααααααααααΆααΎ PLC.
ααα αΆαααΈ 7α αα·αα·αααααΎααααααααΆα α―αααΆαααα αα·αααΆαααΆααααααΈα’ααααααααααααα
αααα‘αααααααααααααΆ (Timer relays) ααααΌαααΆαααααΆαααααΆααααΆααΌαα ααΆαα½ααααα»ααααααααΆα IEC 61812 αααααΆαααααα‘αααααααααααααΆα αα αααα»αααααααααΆααααααα α―αααΆαααααααααΌαααΊα’αΆαααααααΎααΈααααΆαααααα αααααααΆαααΌααααΎα αα·ααααααααα αα αααααααααα’αα·αα·ααα.
αα»ααααα’αα»ααα ααΌααα·αα·αααααΎαα
- αααααΉααα·ααααααααα·ααα (Product datasheet)
- ααααΌαααααΆααααΆαααααααααΎα
- ααΆααΆαααααααααααααΆ (Timing chart)
- αα½αααααααα»ααααααααααα (Supply voltage range)
- ααααα·ααααααααΆαααααΆαααααααα·αααααααΆαααααααααααα»α (Output contact ratings by load type)
- ααΆααααααΆααα ααα»α αααααΆαα (Terminal marking)
- αα·ααΆαααααααΆαααα‘αΎα (Mounting dimensions)
- ααααα·ααααααααααα·ααααΆα (Environmental limits)
- α―αααΆααααααΆαα α¬α―αααΆαα’αα»αααααΆααααααΆαααααΌαααααΆααααΆαα
- ααΆαα’αΆα ααααΆααααααΌααααααα½α α¬αααΌααααααααΆααααααααααα αΆαααααα αα
αα»ααααααααΆα§ααααααααααΌααααααΆ (Relay) αα½αααΆααααααααααααα αααααΆαααααα·ααααααααααααα αααα»αααΆααΆα‘α»ααααα½ααΆααααα½αααΆααααααΆαααααΆαααα»αααΆαα ααΌααααααααααΆααααααααΌααα αα·αααααα·αααΆαααα±ααααΆαααααΉαααααΌαα.
αααααΆααααΆαααααααΆααα·αααααααα αα ααααα ααΌαααΎα ααααα’αΆααα·αααααααα αα ααααα αα·ααααααααα·αααααααα§ααααααααααΌααααααΆαααααΆαααα (Time Delay Relay). αααααΆααααααααΆαααααααΆααααααααααΆαα’αα»αααααΆααααααααΆα ααΌαααΎα ααααα»αααααααααΆαα’αα»αααααΆααααααααΆα IEC 61812-1 αααααΆααα§ααααααααααΌαααααααΆαααα (Time Delay Relay).
ααααααΆααααααα’αααααααααααααα§ααααααααααΌααααααααααααααΆ (Timer Relay)
αααα½αα±ααααΆαααααΎαααΎαα§ααααααααααΌααααααααααααααΆααΆααααΆαααΈα α α¬αα½αααααα ααΌαααΆααααααα’αααααααααααααααΆααααααΆαααΆααααααααααα·ααααααα αα·ααα»αααΆαααα―αααΆααα αα αααααα.
ααΌαααααΎαααααΈαααα½ααα·αα·ααααααα
| ααΆααααα½ααα·αα·αααα’ααααααααααααα | α ααα»α’αααΈααΆαααΆααΆααααΆαα |
|---|---|
| ααΆααΆααα»αααΆαα αααΆααααΆαα | ααΆαααΆαααΆαααααΎαααΎαααααααααα·ααααα·ααΆααα»α |
| ααααΌαααΆαααααααααΎααααααΆαααΆαααααΉαααααΌα | ααΆαααααααααΆαααα α»ααααααααα»ααααααΆααα±ααααααΎαααΆα |
| ααααα·ααααααααΆαααααΆααααααααΆαααααααααααα»α | ααΆαααΆαααΆαααΆααααα’α·αααααααΆαααααα α¬ααΆαααΌα ααΆααα»αααΆαααααα |
| αααααΎαααααααααα»α | αα½αααααα½ααααααΆααα ααΆααααΆαααααααΆααΆααααααααΆαααα |
| αααααΎααααααΆααααααΌαααα DIN αα·αααααααα | ααΆαααααααααΆααααα αααΌααααΎαααααααααααΆ |
| ααΆαα’αΆα ααααΆααααααΌααααααααΆααααα·αααΆα | ααΆααααααααααα αΆααααΆααααα½ααα αααα’ααΆαα |
| αααα½ααα αα ααααα | αα½ααααα’αααααα‘αΎαααααΆαααααααΆ (Panel builders) αα·ααααα»αα αα»αααα·αα§αααααααΎα (OEMs) αααα»αααΆαααααΎαααΎαααΆαααααΉαααααΌα |
| ααΆαααα ααα αα/ααΆαααΆαααααααααΆαα OEM | ααΆααααααααααααααΆααα’αααα ααα αΆα αα·ααααααααααΆαααΈα αααααΆαααααα½α (Private-label) |
αααααΆααααΆαααΆααααααααααα·ααααα»αα αα»αααα·α ααΌαααΎα ααααΆαααααΌαααα·α αα·α ααααα»αααααααααααΎαααΎααααα»αα αα»αααα·αα§αααααααααααααααααΆ (Time Relay).
ααα α»αααααααΌαα αααα»αααΆαααααΎαααΎαα§αααααααααααααααααΆ (Timer Relay)
ααα α»αααΈ α‘α ααΆαααααΎαααΎααααααα’ααααΎαααααααΆαααααΆααααα½ααα»α
αα½ααααααααΆα’αΆα ααααΉαααααΌα ααα»ααααααα»ααααααααααα αααααα»αααΆα ααααα·ααα·ααααααααααΆαααααα (contact rating) α¬αααααα·ααααΆααααΆααΈαα’αΆα αα·αααααΉαααααΌαα.
ααα α»αααΈ α’α ααΆαααΆααα ααα‘ααααΆαααα»ααααααααααα αα·αααα»αααααΆαααααα
αααα‘αααααααααααααΆ (timer relay) αααααααΎααΆααα 24 VDC α’αΆα ααΆαααααΆαααααααααααααααααααΆααααααααΈαααααα ααααΆααΈαααααααααααααΆααα αα·αααααΆααααααααααααααΊααΆαααααααα αα αααααααΆα ααααα‘ααααΈααααΆα.
ααα α»αααΈ α£α ααΆααα·αα’αΎααΎααΉαααααα·ααααα»αα’αΆαααα»α ααα (inductive load rating)
αααααα»ααααααα»αααΆααααα (contactor coils) ααΌααααΌα’ααΈα αααΆαα αα·ααααΌαααααΌα α αααααΎαααΆαααΆαααΉααααααααΆαααααααααα‘ααα»αααΈααααα»ααααααα (resistive loads)α ααΌααα·αα·αααααΎααα·αααααα AC-15 α¬ DC-13 αααα»αααααΈαααα’αΆα α’αα»ααααααΆαα.
ααα α»αααΈ α€α ααΆαααααΎαααΎααα»αααΆαα αααΎα (multifunction) αα ααααααααΆαααΆααααααΆαααΆααααααΆαα
αααα‘ααααααΆααα»αααΆαα αααΎαααΆαααΆααααααα ααα»ααααααΆαααααααααα α¬αα½ααα·αααααΉαααααΌαα’αΆα αααααΆαα±ααααΆαααα α»ααααα»αααΆαααΆααα±ααααααΎαααΆαα αααααΆααααΆαααααΎααααΆαααααααααααα·αααααΆααααααΌα αααα‘ααααααΆααα»αααΆααααα½αα’αΆα ααΆαααΆαααΆααααα½αααΆαα.
ααα α»αααΈ α₯α ααΆαααααΎαααΎααα½ααααααααΆααααα
αα½ααααααααΆααα’αΆα ααααΆαααα ααΆααααααααα ααα»ααααααΆα’αΆα ααααΎα±ααααΆααααααα±ααααΆαα αααΆααααΆααααΆαααΆαααααΆααα ααΎαα»αααΆααα’αΆααΆα‘αΌαα.
ααα α»αααΈ α¦α ααΆααααααΆαααααααα»ααα α ααα»α A1/A2 αα·αααααΆαααααααααα αα (Output contacts)
ααααΆααΈαααααααααααααΆααααααααααα‘ααααααααΆααααααα§αααααααααααααααααΆ (Timer)α ααααΆαααααααααα ααααααΎααΆαααΆαααααααααΈααΆα ααααα‘αααα½αα ααΆαα ααα‘αα ααα»α ααΆαααααααΊααΆααα α»αααΌαα αα αααα’αα»ααααααΆαααααααα.
ααα α»αααΈ α§α ααΆαααααΎααααΆαααααα‘αααααααααααααΆαααααααΆααααααΆαααα»αααΆααα»ααααα·ααΆα
αααα‘αααααααααααααΆααααααΆαα·ααααααΆα§αααααααααααααααααΆαα»ααααα·ααΆααααααααααααααααα·ααα ααααα·αααΎααΆαααααααααααααΆααΆααααααα½ααααα»αααΆααααα½ααα·αα·ααααα»ααααα·ααΆα ααΌαααααΎα§ααααα αα·αααααΆαααααααααααααααΌαααΆααα ααΆ αα·ααααααΆαααααααΆαααα½ααΆααΈαα»ααααα·ααΆααααα.
αααα½ααααα½αααΉαααΆαα
ααΎα’αααΈααΆα ααα»α ααααΌααααααααΌααα·αα·ααααα αααααααΎαααΎααααα‘αααααααααααααΆ?
α αΆααααααΎαααΈαα»αααΆαα αααααααΆααΎααααααΈααααΌαααΆααα»αααΆα On-delay, Off-delay, Interval, Cyclic, Star-delta α¬αα»αααΆαααααααααααααΆα αααα»αα αααααΆααααΈααα ααΌααα·αα·αααααΎαααα»ααααααααααα ααααα·αααααΆαααααα (Contact rating) αα½ααααααααΆ ααΆαααα‘αΎα αα·αααΆααααααΆααααααα.
ααΎαααα»ααα½αααααΎαααΎαααα»ααααααΆαααααααααΈα‘α (Timer Relay) αααΆαααΌα ααααα ?
ααΌαααααΎαααΎαααα»ααααααααααααααααΆααααΈα‘αα±ααααααααΉαααααααΈαααααΆαααααααΆαααα ααΉαα ααα»α αααααΆααααΆαααααααααΈα‘α αααααΆααΌαα ααΊ A1/A2α αα»αααααΎαααΎαααα»ααααααααααααααααα’ααααααΎααα»αααααααα»α (Load) αααααααΌααα·αααΎααααααααΆαααααααα·ααααα (Output contact) α±αααααα.
ααΎαααααααΈα‘αα’αΆα αα·αααΎααααΌααααααααααΆααααΆααααα¬αα?
ααΆααΌαα ααΊαα·αααΆαααα αα αααα»αααααΆαααααααΆαααΌαααααΆαα αααΎα αααααααΈα‘αααααΎααΆααα·αααΎαα§ααααααα»αααΆααααα (Contactor coil) α¬ααααααΈαααααΆ α αΎααα»αααΆαααααααΊααΆα’ααααα·αααΎαααΆααααααααααΌαααα ααΆααα·αααΎααααΌααααααααααΆαααααααΌαα±ααααΆαααααα·ααααααααΆαααααΆαααααα (Contact rating) ααααααααααααααΆααααααα»ααααααααααα.
ααΎαααα»ααα½ααα·αα·αααααΎαααααα·ααααααααΆαααααΆαααααα (Contact rating) α’αααΈαααα?
ααΌααα·αα·αααααΎαααα»α, α αααα, ααααααααααα»α AC/DC αα·αααααααααααα»α (Load category)α αααααΆααααααα»ααααααΆααααααα’αΆαααα»α ααα (Inductive control loads) ααΌααα·αα·αααααΎαααααα·αααΌα ααΆ AC-15 α¬ DC-13 ααΆαααΆαα αΆαααΆα α αα·ααααααααΉαααααΎαααααα·αα’αααααααααΆααααααα»ααααααα (Resistive-load) αααααα.
ααΎαααααααΈα‘ααααααααα α»αα»αααΆα (Multifunction timer relay) ααα’ααΆααααα¬αα?
ααΆααα’αααααΎααα ααααααααααΆαααααααΆααααΌαααΆαααΆααααααα ααΆαααααΎαααααααΆα α¬ααΆαααααΆααααααΌααα»αααΆααα αααα’ααΆααα ααα»ααααααΆαα·ααααααααα’αααααΆαααααααα·ααΈαααααααΎααααΆααααααα αα·ααααααααα αααααααΆαααααααα»αα’αΆα ααααα αΆαα·αααα αααΎαααΆαααα ααααα.
ααΎ A1 αα·α A2 ααΆααααααΌα ααααα αα ααΎα§αααααααααααααααααΆ (Timer Relay)?
A1 αα·α A2 ααΆααΌαα αααααΆααααΎα ααα»α αααααΆααααΆαααααααα§αααααααααααααααααΆα ααα»αααΆααααΆαα ααΆαααααΎααααΆααααΆαα½αα αααα AC/DC αα·ααααααΌαααΆααααΌα (Polarity) ααααΌααααα·αα·αααααΎααα ααΎααααΆααααααΆααααα§ααααα α¬αααααΉααα·αααααααα αα αααααα.
ααΎααα 15, 16 αα·α 18 ααΆααααααΌα ααααα αα ααΎα§αααααααααααααααααΆ?
αα ααΎα§ααααααααααΌααααααΆ (Relay) α§ααααΆα ααααααΆα αααΎα ααα 15 ααΊααΆα ααα»α αα½α (Common) ααα 16 ααΊααΆα ααα»α αα·αααααααΆ (Normally Closed) αα·αααα 18 ααΊααΆα ααα»α ααΎαααααααΆ (Normally Open)α αααααΆααΏαααααααΆ ααα»αααααα·ααααααΆαααααααΆααααααΆααααααααααΌαααααααα ααΌα ααααααΌααα·αα·αααααΎαααααΆααααΆαααααααααΎαααΆαα·α αα α.
ααΎα’αααΈααΆααΆααα»αααααΆαααΆαα§αααααααααααααααααΆ (Timer Relay) αα·αα§αααααααααααααααααΆαααα»α PLC?
α§αααααααααααααααααΆ (Timer Relay) ααΊααΆα§αααααααααααααααααΆααΆα ααααα‘ααααΈααααΆα α ααααα§αααααααααααααααααΆαααα»α PLC ααΊααΆαααααα·ααααΆαααααα·ααΈ (Software logic) ααααααα·ααα ααΆααααα»αα§ααααααααααΆαααα’αΆα ααααααααααα·ααΈααΆαα ααααΎ Timer Relay αααααΆααααΆαααααααααααααΆαααα»αααΌαααααΆααααααΆαααα αα·αααα α ααααα―ααΆαααααααααααααΆαααα»α PLC ααΊαααααΆααααααΆααααΆαααΆααααα»αααααΆα ααΆαααααΎααααα·αα·α αααα ααΆαααααΆαααααα αα·ααααααα·ααααΆαααα’αΆα ααααααα½αααΆαααΆαααα HMIα.
ααΎαααααααΆαα’αααΈαααααααα’αα»ααααα ααααα§αααααααααααααααααΆ (Timer Relay)?
αααα»ααααααααΆα IEC 61812 ααααΌαααΆααααααααΆααΌαα αααααΆααα§αααααααααααααααααΆα ααΆαα’αα»αααααΆααααααααΆαααΆαααααααααΊα’αΆαααααααΎαααΌαααααα·ααα α―αααΆααα αα ααααα ααΈααααΆαααααα αα·ααααααΌαααΆαααααααααα.
αααααα
ααΆαααααΎαααΎαα§αααααααααααααααααΆ (Timer relay) ααααΉαααααΌα ααΊααααΌαααα’ααααΎαα»αααΆαααΆα αααα αααααΆααααααΊααΆααααααααααααα’αααα·αααΈ αα·αααααΆαα·α α ααΆαααααΎαααΎαααααα’αα½αααααΌααα·αα·αααααΎααααααααααααααααΆ ααα»ααααααααααα ααααα·ααααα»αααααααααΆαααααα (Contact rating) αα½αααααααααααααΆ ααΆααααα αααααΆαααααααααααα ααΆαααα‘αΎα ααααΆααΈαααααααααΎα αα·αα―αααΆααα αα αααααα.
αααααΆααααΆαααααΎαααΎαα§αααααααααααααααααΆ VIOX ααΌαα αΆααααααΎαααΈ ααααΆαααααΌα αααααααα·ααα αααααΆααααααααΎααααΆααααααα»ααααααααααα½ααααααΆαα ααααΆααααΆαααααααααΎα, ααΆαααααΎαααΎαααα»α, ααΆαα’αΆααααααΉααα·αααααααα αα ααααα (Datasheet), αα·α ααααα·ααααα»αααααααααΆαααααααααααΆααααααα»αα’αΆαααα»α ααα (Inductive load).
Sources Used
- VIOXα ααΎα’αααΈαα ααΆα§αααααααααααααααααΆ (Time Relay)?
- VIOX: ααααα»αααααααααααΎαααΎαααα»ααααααΆααα§αααααααααααααααααΆ (Timer Relay)
- VIOX: ααααα»αααααααααααΆααααΆαααααααααΎααααααΆααα§αααααααααααααααααΆ (Time Delay Relay)
- VIOX: ααααα’αΆααααααΉααα·αααααα αα·ααααααααα αα αααααααααα§αααααααααααααααααΆ (Time Delay Relay)
- αααααΈαααααααΆα IEC: α§αααααααααααααααααΆ IEC 61812